Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR WINDOW SILLS | FRONT WINDOW SILL WASHED OUT MORTAR | 8033 S RHODES AVE | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | PLAKING PAINT AROUND WINDOWS | 8033 S RHODES AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | FRONT CORNICE WASHED OUT MORTAR | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | 3 STORY WOOD OPEN PORCH: COLUMNS EREDCTED ON TOP OF CONCRETE SLAB.; COLUMNS ARE STACKED ONE ON TOP OF OTHER.;3RD FLOOR NORTH BEAM - ROTTED AND SCABBED.; ROOF RIM JOIST ROTTED AT COLUMN CONNECTION.; GUARDRAILS ARE ONLY 35-1/2" HIGH, END POST FASTENED TO EXTERIOR WALL WITH NAILS.; GUARD AND HANDRAILS - MISSING MANY PICKETS.; STINGERS ONE SIDE FASTENED WITH NAILS ONLY.; TREADS ARE ONLY 9-1/4" WIDE.PLANS AND PERMIT REQUIRED TO REPLACE D&H PORCH. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
EXPOSED WIRING FIXTURES | INTERIOR STAIRWAY'S & BASEMENT | 8033 S RHODES AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | BROKEN LIGHTS & COVERS MISSING EXTERIOR & BASEMENT | 8033 S RHODES AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | BASEMENT | 8033 S RHODES AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | EXPOSED RUNS IN BASEMENT | 8033 S RHODES AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | 8033 S RHODES AVE | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE FOR 2016 ANNUAL INSPECTION AND TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID. SIGN. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST AND NORTH ELEVATION - WASHED OUT MORTAR. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR PLATFORM | FRONT ENTRYWAY WING WALLS - WASHED OUT MORTAR. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | WEST BASEMENT WINDOW - BROKEN SASH. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | WEST 1ST FLOOR WINDOW LINTELS - RUSTED AND DEFLECTING - PLANS AND PERMIT ARE REQUIRED TO REPLACE WINDOWS. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS MISSING SEVERAL WINDOW AND DOOR SCREENS | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | BRICK GARAGE - ROOF COLLAPSED, WASHED OUT MORTAR, BROKEN WINDOWS AND SERVICE DOOR. PERMIT REQUIRED TO WRECK OR REPAIR GARAGE. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
RAT PROOF BSMENT DOOR | EAST BASEMENT DOOR - APROX 2" OPEN GAP.(BOTTOM). | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS GRADE TO BASEMENT - MISSING HANDRAIL. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
OPEN | 8033 S RHODES AVE | PERMIT | PASSED | View | |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR YEARS 1990-2009. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
TENANT ACCESS TO SERVICE | 8033 S RHODES AVE | COMPLAINT | FAILED | View | |
SERVICE WALK, PASSAGE, AREAWAY | NORTH SERVICE WALK - CONCRETE HAS HOLES. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST AND NORTH ELEVATIONS - BROKEN WINDOW PANES. | 8033 S RHODES AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | INTERIOR STAIRWAY'S & BASEMENT | 8033 S RHODES AVE | COMPLAINT | FAILED | View |