Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
PARAPET NORTH PARAPET WALL - SPALLING AND LOOSE BRICKS. 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT CONCRETE PORCH: DECK LINTEL RUSTING AND SAGING - PERMIT REQUIRED FOR LINTEL REPLACEMENT. 2352 S LAWNDALE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPLACE D&H PORCH WEST ELEVATION - 3 STORY OPEN WOOD PORCH.6X6 COLUMNS ARE OVERNOTCHED,BOWED,ROTTING AND ARE ERECTED ON TOP ORF CONCRETE SLAB.STATUS OF FOUNDATIONS UNKNOWN.2X8 JOISTS ARE ROTTED.6X6 BEAMS ARE ROTTED AND FASTENED WITH LIGHT GAUGE METAL STRAPS AT BEAM TO COLUMN CONNECTIONS.RAILINGS ARE 32" HIGH,LOOSE,MISSING PICKETS,ROTTED AND TOENAILED TO COLUMNS.STRINGERS ARE ROTTED AND FASTENED TO RIM JOISTS WITH NAILS ONLY.TREADS AND DECK BOARDS ARE LOOSE,ROTTED AND WORN.PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. 2352 S LAWNDALE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT ATTIC AND 2ND FLOOR STAIRWAYS ; BASEMENT, 1ST , 2ND FRONT, 2ND REAR AND ATTIC FLOORS - MISSING SMOKE ALARMS. (14X-5-504.8.4) (14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, AND 14R-11-1104, 14X-5-504.8.4 ) 2352 S LAWNDALE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT, 1ST , 2ND FRONT, 2ND REAR AND ATTIC FLOORS - MISSING CARBON MONOXID ALARMS. (14X-5-504.9, 14B-9-915.1.1, 14B-9-915.2, AND 14R-11-1105) 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING ATTIC , FRONT ATTIC AND MAIN STAIRWAY - HOLES AT WALLS AND CEILINGS 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPLACE D&H PORCH WEST ELEVATION, REAR GRADE TO ATTIC 4 LEVEL PORCH SYSTEM - LOOSE GAURDRAILS AT 36" HEIGHT, LOOSE AND MISSING BALSUTERS, COLLAPSING STAIRS FROM SECOND FLOOR TO GRADE , LOOSE STRINGERS,TREADS AND RISERS THRU-OUT. VERY ROTTED STRUCTURAL BEAMS COLUMNS, STRINGERS,STAIRS AND JOISTS THRU-OUT. LOOKOUT BEAMS ARE EXCESSIVLY SHIFTED AND ALMOST NOT BEARING ON THE COLUMN NOTCHES. DANGEROUS AND HAZARDOUS. RECOMMEND NO LIVE LOADS OR HUMAN USE. PLANS AND PERMITS ARE REQUIRED FOR REBUILD. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL 2352 S LAWNDALE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND ATTIC OR RESTORE TO THE ORIGINAL STATE.(14A-4-401.1 THRU 14A-4-404.22, 14A-4-410.1, 14A-4-411 THRU 14A-4-411.3, TABLE 14A-12-1204.2) 2352 S LAWNDALE AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD - ABANDONED CAR, JUNK AND DEBRIS. RAT HARBORAGE ,; LOOSE CATCH BASIN COVER - CONCRETE IS CRACKED 2352 S LAWNDALE AVE COMPLAINT FAILED View
WORK NOT ALLOWED NC2071 - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE ATTIC AND BASEMENT WITHOUT PERMIT.( SEC 14-3-301.1 ,14A4-413.1, 14A-4-413.8.1 2352 S LAWNDALE AVE COMPLAINT FAILED View
PROVIDE REAR ALLEY - NO PERMIT ON RECORD FOR 6' FENCES/ GATES , PER SEC. 14A-4-404.7 IT IS UNLAWFUL TO ERECT A FENCE MORE THAN 5 FEET (1524 MM) IN HEIGHT WITHOUT FIRST OBTAINING A PERMIT FROM THE BUILDING OFFICIAL. 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT AND ATTIC STAIRWAY - LOOSE TREADS AND RISERS AT VARIOUS LOCATIONS. UNSAFE 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS EAST ELEVATION - OPEN SILL JOINTS. 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EAST FRONT STAIRS - SPALLED NOSINGS.WEST BASEMENT STAIRS - MISSING HANDRAIL AND GAURDRAIL. 2352 S LAWNDALE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION - STEP FRACTURES AND ERODED MORTAR AT VARIOUS LOCATIONS. 2352 S LAWNDALE AVE COMPLAINT FAILED View