Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - MANAGEMENT INFORMATION NOT POSTED. | 1856 S HARDING AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR WOOD STAIRWAY / GRADE TO 1ST - LEDGER BEAM ONLY FASTENED WITH CUT NAILS TO BUILDING. STAIR RAILINGS LADDER TYPE, LOOSE AND PULLING. GUARD RAILS ONLY 32 INCHES HIGH. STEPS UNEVEN IN HEIGHTS FROM 6 TO 8 INCHES.TREADS CUPPED AND DEFLECTING.FRONT EXTERIOR CONCRETE STAIRWAY / GRADE TO BASEMENT - MISSING RAILS.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF FRONT WOOD STAIRWAY. | 1856 S HARDING AVE | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY'S MISSING CAPS. | 1856 S HARDING AVE | COMPLAINT | CLOSED | View |
CHIMNEY | CHIMNEY'S WITH OPEN MORTAR JOINTS. | 1856 S HARDING AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATIONS/EXTERIOR WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | 6 FOOT HIGH CHAIN LINK FENCE BUILT WITHOUT A PERMIT. PERMIT NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR GATES - LOCKED WITH CHAIN AND PADLOCK. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR EXTERIOR ENTRANCE DOOR - MISSING DOOR KNOB. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | BASEMENT WINDOWS - BOARDED UP. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO VERIFY THE COMPLAINT OF WATER DAMAGE, INSECTS, MICE, MILDEW AND UNABLE TO INSPECT REAR PORCH. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5 FEET REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | WEST ENCLOSED WOOD PORCH FLOOR HAS UNDERSIZED FLOOR JOISTS FOR SPAN. IMPROPER BEAM TO COLUMN CONNECTIONS UNDERSIZED GUARD RAILS. INCORRECT COLUMN SPLICES, PORCH SYSTEM SWAYS SIDE TO SIDE. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | REPAIR OR REPLACEMENT OF WEST ENCLOSED PORCH WILL REQUIRE PLANS AND PERMITS. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLY TO KITCHEN FAUCET, LAVATORY AND TOILET 1ST FLOOR RESTROOM. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
OBTAIN PERMIT FOR PLUMBING | PROVIDE PERMIT TO RELOCATE WATER HEATER TO BACK PORCH WEST ELEVATION 1ST FLOOR. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | WATER HEATER 1ST FLOOR WEST ELEVATION PROPER MATERIAL. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLY TO WATER HEATER 1ST FLOOR WEST ELEVATION. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | REPAIR VANDALIZED POWER SERVICE AND INSTALL PUBLIC METER AND PANEL. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROVIDE | NO SAFE PAN UNDER WATER HEATER 1ST FLOOR WEST ELEVATION. 18-29-504.8. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
CHIMNEY | REAR CHIMNEY-LEANING,SPALLED BRICKS AND WASHED OUT MORTAR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | REAR CHIMNEY CAPPING- BROKEN CAPPING AND WASHED OUT MORTAR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION- EXTERIOR MASONRY WALL,AT GRADE,WASHED OUT MORTAR.SOUTH ELEVATION,AT GRADE,SPALLED BRICKS AND WASHED OUT MORTAR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | FIRST FLOOR APT. IN KITCHEN,WATER DAMAGED FLOOR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | FIRST FLOOR APT. MICE DROPPINGS OBSERVED IN THE KITCHEN CABINETS,UNDER KITCHEN SINK. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR COPING | FRONT ELEVATION- STONE COPING- WASHED OUT MORTAR. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS/SCREENS - TORN AND MISSING. | 1856 S HARDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT AND 2ND FLOOR. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TOILET SEAT | 1ST FLOOR RESTROOM TOILET SEAT CRACKED. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROVIDE | WEST ENCLOSED PORCH GRADE TO 2ND FLOOR HAS EXPOSED WOOD STUDDING. 34(13-200-260)(2). | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD HAS GARBAGE AND DEBRIS. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROVIDE | NO FLOOR DRAIN FOR WATER HEATER 1ST FLOOR ELEVATION. (18-29-508.8 THRU 18-29-504.8.2) | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
PROVIDE | NO CONTROL VALVE ON COLD SIDE OF WATER HEATER 1ST FLOOR WEST ELEVATION. (18-29-503.1) | 1856 S HARDING AVE | COMPLAINT | PASSED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS. | 1856 S HARDING AVE | COMPLAINT | PASSED | View |