PIN: 16233080390000
Property Address: 1856 S HARDING AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 100
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77125
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 36 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING - MANAGEMENT INFORMATION NOT POSTED. 1856 S HARDING AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR WOOD STAIRWAY / GRADE TO 1ST - LEDGER BEAM ONLY FASTENED WITH CUT NAILS TO BUILDING. STAIR RAILINGS LADDER TYPE, LOOSE AND PULLING. GUARD RAILS ONLY 32 INCHES HIGH. STEPS UNEVEN IN HEIGHTS FROM 6 TO 8 INCHES.TREADS CUPPED AND DEFLECTING.FRONT EXTERIOR CONCRETE STAIRWAY / GRADE TO BASEMENT - MISSING RAILS.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF FRONT WOOD STAIRWAY. 1856 S HARDING AVE COMPLAINT CLOSED View
CHIMNEY CAPPING CHIMNEY'S MISSING CAPS. 1856 S HARDING AVE COMPLAINT CLOSED View
CHIMNEY CHIMNEY'S WITH OPEN MORTAR JOINTS. 1856 S HARDING AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL NORTH AND SOUTH ELEVATIONS/EXTERIOR WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR FENCE 6 FOOT HIGH CHAIN LINK FENCE BUILT WITHOUT A PERMIT. PERMIT NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL. 1856 S HARDING AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT AND REAR GATES - LOCKED WITH CHAIN AND PADLOCK. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE REAR EXTERIOR ENTRANCE DOOR - MISSING DOOR KNOB. 1856 S HARDING AVE COMPLAINT FAILED View
MAINTAIN WINDOW BASEMENT WINDOWS - BOARDED UP. 1856 S HARDING AVE COMPLAINT FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO VERIFY THE COMPLAINT OF WATER DAMAGE, INSECTS, MICE, MILDEW AND UNABLE TO INSPECT REAR PORCH. 1856 S HARDING AVE COMPLAINT FAILED View
WORK NOT ALLOWED STEEL PICKET FENCE OVER 5 FEET REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. 1856 S HARDING AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM WEST ENCLOSED WOOD PORCH FLOOR HAS UNDERSIZED FLOOR JOISTS FOR SPAN. IMPROPER BEAM TO COLUMN CONNECTIONS UNDERSIZED GUARD RAILS. INCORRECT COLUMN SPLICES, PORCH SYSTEM SWAYS SIDE TO SIDE. 1856 S HARDING AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR REPAIR OR REPLACEMENT OF WEST ENCLOSED PORCH WILL REQUIRE PLANS AND PERMITS. 1856 S HARDING AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLY TO KITCHEN FAUCET, LAVATORY AND TOILET 1ST FLOOR RESTROOM. 1856 S HARDING AVE COMPLAINT PASSED View
OBTAIN PERMIT FOR PLUMBING PROVIDE PERMIT TO RELOCATE WATER HEATER TO BACK PORCH WEST ELEVATION 1ST FLOOR. 1856 S HARDING AVE COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV WATER HEATER 1ST FLOOR WEST ELEVATION PROPER MATERIAL. 1856 S HARDING AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLY TO WATER HEATER 1ST FLOOR WEST ELEVATION. 1856 S HARDING AVE COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS. 1856 S HARDING AVE COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. 1856 S HARDING AVE COMPLAINT PASSED View
INSTALL ILLUMINATION INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. 1856 S HARDING AVE COMPLAINT PASSED View
DEFECTIVE METER EQUIPMENT REPAIR VANDALIZED POWER SERVICE AND INSTALL PUBLIC METER AND PANEL. 1856 S HARDING AVE COMPLAINT PASSED View
PROVIDE NO SAFE PAN UNDER WATER HEATER 1ST FLOOR WEST ELEVATION. 18-29-504.8. 1856 S HARDING AVE COMPLAINT PASSED View
CHIMNEY REAR CHIMNEY-LEANING,SPALLED BRICKS AND WASHED OUT MORTAR. 1856 S HARDING AVE COMPLAINT FAILED View
CHIMNEY CAPPING REAR CHIMNEY CAPPING- BROKEN CAPPING AND WASHED OUT MORTAR. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION- EXTERIOR MASONRY WALL,AT GRADE,WASHED OUT MORTAR.SOUTH ELEVATION,AT GRADE,SPALLED BRICKS AND WASHED OUT MORTAR. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR FLOOR FIRST FLOOR APT. IN KITCHEN,WATER DAMAGED FLOOR. 1856 S HARDING AVE COMPLAINT FAILED View
MICE/RODENTS FIRST FLOOR APT. MICE DROPPINGS OBSERVED IN THE KITCHEN CABINETS,UNDER KITCHEN SINK. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR COPING FRONT ELEVATION- STONE COPING- WASHED OUT MORTAR. 1856 S HARDING AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS/SCREENS - TORN AND MISSING. 1856 S HARDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO BASEMENT AND 2ND FLOOR. 1856 S HARDING AVE COMPLAINT PASSED View
REPLACE DEFECTIVE TOILET SEAT 1ST FLOOR RESTROOM TOILET SEAT CRACKED. 1856 S HARDING AVE COMPLAINT PASSED View
PROVIDE WEST ENCLOSED PORCH GRADE TO 2ND FLOOR HAS EXPOSED WOOD STUDDING. 34(13-200-260)(2). 1856 S HARDING AVE COMPLAINT PASSED View
STOP/REMOVE NUISANCE REAR YARD HAS GARBAGE AND DEBRIS. 1856 S HARDING AVE COMPLAINT PASSED View
PROVIDE NO FLOOR DRAIN FOR WATER HEATER 1ST FLOOR ELEVATION. (18-29-508.8 THRU 18-29-504.8.2) 1856 S HARDING AVE COMPLAINT PASSED View
PROVIDE NO CONTROL VALVE ON COLD SIDE OF WATER HEATER 1ST FLOOR WEST ELEVATION. (18-29-503.1) 1856 S HARDING AVE COMPLAINT PASSED View
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS. 1856 S HARDING AVE COMPLAINT PASSED View