Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 4:57 AM
PIN: 16103100060000
Property Address: 4519 W LAKE ST
City - Zip: CHICAGO - 60624
2023 Property Class: 522
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77110
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 41 Violations
Violation Inspector Comments Address Category Status View
REPAIR INTERIOR STAIR SYSTEM GRADE TO BASEMENT HAS DANGEROUS AND HAZARDOUS STAIRS, BROKEN TREADS/STRINGERS AT BOTTOM OF STAIRS, INCORRECT RISER HEIGHTS AND WORN TREADS, MISSING HANDRAILS. 4519 W LAKE ST COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) 2X8 CEILING JOISTS AT EAST ELEVATION 13 TOTAL, AT 16' SPAN SHOWS THEY ARE DEFLECTING DOWNWARD CAUSING THAT SECTION OF ROOF STRUCTURE TO BE COMPROMISED AND IS A DANGEROUS AND HAZARDOUS CONDITION. ROOF STRUCTURE PLANK SHEATHING ARE WATER DAMAGED. ELEVATED WOOD PLATFORM SPANNING 20' RESTING ON BOW TRUSS RAFTERS. ALL REQUIRE A STRUCTURAL ENGINEER'S REPORT. 4519 W LAKE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ELEVATED 2X8 WOOD PLATFORM SPANNING 20' OVER SHOP NORTH ELEVATION RESTING ON BOW TRUSS RAFTERS AND SOUTH ELEVATION NOT SITTING IN BRICK/MORTAR POCKET. CENTER OF WOOD PLATFORM SUPPORTED BY FLAT STOCK ATTACHED TO ROOF STRUCTURE. CONSTRUCTED WITHOUT PLANS/PERMITS. 4519 W LAKE ST COMPLAINT FAILED View
WORK NOT ALLOWED STEEL PANEL FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. 4519 W LAKE ST COMPLAINT FAILED View
NO BARBED WIRE ON FENCE < 8FT REAR STEEL PANEL FENCE HAS RAZOR WIRE. 4519 W LAKE ST COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS HAVE EXPIRED TAGS. 4519 W LAKE ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST/SOUTH WALLS HAVE LOOSE/MISSING MORTAR. SOUTH WALL HAS A STRESS CRACK. 4519 W LAKE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NEW NON-LOAD BEARING WOOD PARTITION WALLS FORMING A 20X26 ROOM WITH ELEVATED MEZZANINE WITH WOOD STAIRS 1ST FLOOR HAS LARGE ROOM, BATH, CLOSET. MEZZANINE HAS LARGE ROOM WITH BATH ALL CONSTRUCTED WITHOUT PLANS/PERMITS. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE TRIPLE BASIN (18-29-1003.7.2) 15 CARS IN GARAGE. 4519 W LAKE ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLY TO TOILET NORTHWEST ELEVATION 1ST FLOOR. 4519 W LAKE ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS. 4519 W LAKE ST COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. 4519 W LAKE ST COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT NO PERMITS FOR ROUGH PLUMBING, WATER WASTE AND VENT PIPING: 1ST FLOOR LAVATORY, TOILET, LAUNDRY BOX, LAUNDRY TUB NORTHWEST ELEVATION. 2ND FLOOR LAVATORY, TOILET NORTHWEST ELEVATION. 1ST FLOOR LAVATORY, TOILET WEST ELEVATION. 4519 W LAKE ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REMOVE ALL PVC WASTE AND VENT PIPING 1ST AND 2ND FLOORS NORTHWEST ELEVATION, 1ST FLOOR WEST ELEVATION, BASEMENT NORTHWEST ELEVATION, BASEMENT SUBSOIL PIPING. 4519 W LAKE ST COMPLAINT FAILED View
EXPOSE FOR INSPECT APPROVAL ALL SUBSOIL DRAIN TILE BASEMENT. 4519 W LAKE ST COMPLAINT FAILED View
REMOVE REMOVE PVC WATER PIPE FOR SILCOCKS 1ST FLOOR SOUTH, EAST, WEST ELEVATION. PROVIDE PROPER MATERIAL. (18-29-605.6) 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE RPZ FOR SILCOCKS 1ST FLOOR SOUTH, EAST AND WEST ELEVATION. (18-29-608.13.2) 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE LID FOR SUMP PUMP BASEMENT NORTH ELEVATION. (18-29-1003.12) 4519 W LAKE ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REMOVE 1-1/2 PVC DISCHARGE PIPE AND PROVIDE PROPER MATERIAL BASEMENT NORTH ELEVATION. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE FLOOR DRAIN FOR WATER HEATER 1ST FLOOR NORTHWEST ELEVATION. (18-29-412.4) 4519 W LAKE ST COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS AT FRONT AND REAR OF BUILDING INCLUDING SIDE OF BUILDING. 4519 W LAKE ST COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP REPLACE DEFECTIVE AND BROKEN CONDUITS THROUGHOUT GARAGE - DANGEROUS AND HAZARDOUS. 4519 W LAKE ST COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING THROUGHOUT GARAGE - DANGEROUS AND HAZARDOUS. 4519 W LAKE ST COMPLAINT FAILED View
NO PERMIT WIRING PROVIDE PERMIT FOR ELECTRICAL INSTALLATION TO OFFICE BUILDOUT INSTALLED WITHOUT PERMIT. BOXES, WIRES, AND CONDUITS INSTALLED WITHOUT PERMIT TO 2 STORY OFFICE BUILDOUT. 4519 W LAKE ST COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND UNDERSIZED POWER SERVICE IMPROPERLY INSTALLED. ILLEGAL USE OF EMT MUST BE RIGID. RELOCATE METER TO EXTERIOR REAR OF BUILDING AND INSTALL MINIMUM 400 AMP POWER SERVICE. SERVICE NOT PROPERLY GROUNDED TO WATER MAIN - DANGEROUS AND HAZARDOUS. 4519 W LAKE ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES THROUGHOUT SPECIFICALLY IN SPRAY AREA. ALL ELECTRICAL EQUIPMENT MUST BE EXPLOSION PROOF. 4519 W LAKE ST COMPLAINT FAILED View
(18-27-110.5) REMOVE ALL UNWORKMANLIKE INSTALLATIONS OF CONDUITS AND WIRING AND INSTALL PROPERLY. 4519 W LAKE ST COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS THROUGHOUT GARAGE. 4519 W LAKE ST COMPLAINT FAILED View
ADD RECEPTACLES INSTALL ADDITIONAL OUTLETS TO AVOID USE OF CORDS. 4519 W LAKE ST COMPLAINT FAILED View
(18-27-516.2.(1)(2)(3)(4)(5)(6) INSTALL SPRAY BOOTH CLASS I OR ISOLATE ROOMS DESIGNATED FOR SPRAYING AUTOMOBILES AND ROOM DESIGNATED FOR DRYING. ALL FIXTURES AND ELECTRICAL EQUIPMENT MUST BE EXPLOSION PROOF FOR CLASS I LOCATION. 4519 W LAKE ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS (13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT TOILET NORTHWEST ELEVATION 1ST FLOOR. 4519 W LAKE ST COMPLAINT FAILED View
(18-27-516.3A) ALL WIRING AND EQUIPMENT WITHIN CLASS I LOCATION SHALL BE EXPLOSION PROOF TYPE. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE DRINKING FOUNTAIN. (18-29-403.1) 4519 W LAKE ST COMPLAINT FAILED View
(18-27-210.8) INSTALL GFCI'S TO GARAGE AREAS AND WET LOCATIONS. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE LAUNDRY TUB OR MOP SINK. (18-29-403.1) 4519 W LAKE ST COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS CAP OFF ALL OPEN PLUMBING TO ABATE SEWER GAS THROUGHOUT BUILDING. 4519 W LAKE ST COMPLAINT FAILED View
PROVIDE PROVIDE WORKING LAVATORY IN RESTROOM 1ST FLOOR NORTHWEST ELEVATION. (13-196-360) 4519 W LAKE ST COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT STANDING WATER IN BASEMENT. 4519 W LAKE ST COMPLAINT FAILED View
REMOVE GAS CANS THROUGHOUT BUILDING IMPROPERLY STORED. (15-4-880) 4519 W LAKE ST COMPLAINT FAILED View
OPEN 4519 W LAKE ST PERMIT FAILED View