Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
SERVICE WALK, PASSAGE, AREAWAY NORTH ELEVATION - MISSING CONCRETE SERVICE WALK FROM STEPS TO ALLEY SEVERELY BROKEN /CONCAVED SECTIONS TO THE EAST AND SOUTH 649 N SPAULDING AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE EAST - 1ST FLOOR WINDOW FRAMES WITH ROTTED SILLS , CASINGS AND SASHES OPEN WALL JOINTS 649 N SPAULDING AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 1ST FLOOR APARTMENT WITHOUT A SMOKE DETECTOR 649 N SPAULDING AVE COMPLAINT FAILED View
FLUE PIPE CLEARANCE 6"X 1ST FLOOR APARTMENT WITH WARM AIR FURNANCE EXHAUST PIPE SINGER PLY AND PENETRATING A COMBUSTIBLE PARTITION 649 N SPAULDING AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 1ST FLOOR APARTMENT HVAC INSTALLATION PLANS ARE REQUIRED 649 N SPAULDING AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST INFORMATION PLACARD 649 N SPAULDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION PROVIDE FULL INTERIOR ACCESS- BASEMENT AREAS, 2ND FL FRONT REAR UNITS , 1ST REAR UNIT 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM SOUTH - EXTERIOR PORCH SYSTEM NOT ORIGINAL , SEE DEFICIENT THE FOLLOWING DEFECTS. 1 COLUMNS NOT ANCHORED AT BOTTOM 2. COLUMN LAP JOIST TOE NAILED WITH INSUFFICIENT BOLTS 3 BEAMS WITH OUT TIE STRAPS AT WALL OF FIRE CUT, SEE UNSEAL BEAM POCKETS AT BRICK WALL. 4 STRINGERS TOE NAILED AT ANCHOR ENDS TOP AND (BOTTOM) 5 RIM JOIST TOE NAILED, SOUTH 1ST TO 2ND RESTING ON A CRUMBLING CONCRETE FENCE SECTION. WEAK HAND RAILS GRADE TO 2ND FLOOR. 3 GUARD RAIL END AT WALL WITH CUT NAILS 4 PICKETS ANCHORED OUT SIDE OF BOTTOM RAIL , EASY TO KICK OFF POSITION 7 PLANS AND PERMITS REQUIRED. 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET SOUTH EAST BASEMENT DOOR WITH GAPS AROUND FRAME 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIR WELL HAND AND GUARD RAIL PICKETS SPACED GREATER THAN 4 INCHES B) LOOSE TREADS , BOUNCY BOARDS 649 N SPAULDING AVE COMPLAINT FAILED View
ADD RECEPTACLES ADD RECEPTACLES TO EASE EXTENSION CORD USE THRU OUT 1ST FLOOR UNIT 649 N SPAULDING AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LITES THUR OUT 1ST FLOOR UNIT - 649 N SPAULDING AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS REPLACE ALL PAINTED AND DEFECTIVE RECEPTACLES THRU OUT 1ST FLOOR UNIT AND OTHER TYPICAL UNITS IN BUILDING 649 N SPAULDING AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS AND BATHROOMS- 1ST FLOOR UNIT AND OTHER TYPICAL UNITS IN BUILDING 18.27.210-8 649 N SPAULDING AVE COMPLAINT FAILED View
PROVIDE WEATHER PROOF BOXES , LITES AND FITTINGS , THRU OUT PORCH AREAS ON SOUTH SIDE OF BUILDING 18-27-110.11 649 N SPAULDING AVE COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SUPPORT CONDUIT RUNS THRU OUT PORCH AREA'S 649 N SPAULDING AVE COMPLAINT FAILED View
NO PERMIT WIRING OBTAIN ELECTRICAL PERMIT AND CONTRACTORS TO CORRECT VIOLATIONS 649 N SPAULDING AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING. BUILDING NOT REGISTERED 4 OR MORE UNITS 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM PORCH SYSTEM. INSTALL MISSING STRAPS/HARDWARE AT FLOOR JOIST AND 6X6 LOOKOUTS. INSTALL MISSING HANDRAIL AT FRONT CONCRETE STAIRS GRATE TO BASEMENT 649 N SPAULDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY ARRANGE FOR INTERIOR INSPECTION 649 N SPAULDING AVE COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL ILLUMINATION TO MAIN FRONT ENTRANCE ON EXTERIOR 649 N SPAULDING AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE REAR PORCH EXTERIOR LIGHT FIXTURES BASEMENT TO 2ND FLOOR ALL BOXES AND FIXTURES MUST BE WEATHERPROOF 649 N SPAULDING AVE COMPLAINT FAILED View
REMOVE ABANDONED CONDUIT AT SIDE OF BUILDING ABOVE SIDE ENTRANCE. (18-27-110.12(E)) 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FOOTING INSPECTION FAILED - FOOTING DETAILED ON PLANS HAS NO FOOTING, NO REBAR - ON DETAIL - ONLY 12" X 48" PEDELSTAL - CONCRETE BLOCK ROUND IN COLUM - 6X6 COLUMNS - TWISTED AND OVER NOTCHED, RETAINING WALL BOWING 649 N SPAULDING AVE PERMIT PASSED View
FILE BLDG REGISTRATION BLDG. - NOT REGISTERED FROM 2012 THRU 2013 649 N SPAULDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. 649 N SPAULDING AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BLDG. - OWNER'S I.D. SIGN - MISSING 649 N SPAULDING AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE SOUTH AT 1 AND 2 / REAR PORCH DECKING - BARBECUE GRILLS. 649 N SPAULDING AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM 2-STORY / SIDE PORCH - 6X6 COLUMNS TWISTED, OVER NOTCHED AND ERECTED ON BOWING AND CRUMBLING RETAINING WALL. PORCH ONLY SEPARATED FROM ADJOINING BUILDING WITH ONLY 6 INCHES GAP - FIRE HAZARD. PLANS AND PERMIT REQUIRED FOR REPAIRS. 649 N SPAULDING AVE COMPLAINT FAILED View
PARAPET NORTH ELEVATION - PARAPET WALL OUT OF PLUMB AND BULGING OUT. 649 N SPAULDING AVE COMPLAINT FAILED View
PERMIT REQUIRED PERIMETER OF BUILDING ENCIRCLED WITH CHAIN LINK OR IRON FENCING NO PERMIT ON FILE 649 N SPAULDING AVE COMPLAINT FAILED View