Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | NORTH ELEVATION - MISSING CONCRETE SERVICE WALK FROM STEPS TO ALLEY SEVERELY BROKEN /CONCAVED SECTIONS TO THE EAST AND SOUTH | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | EAST - 1ST FLOOR WINDOW FRAMES WITH ROTTED SILLS , CASINGS AND SASHES OPEN WALL JOINTS | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APARTMENT WITHOUT A SMOKE DETECTOR | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
FLUE PIPE CLEARANCE 6"X | 1ST FLOOR APARTMENT WITH WARM AIR FURNANCE EXHAUST PIPE SINGER PLY AND PENETRATING A COMBUSTIBLE PARTITION | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | 1ST FLOOR APARTMENT HVAC INSTALLATION PLANS ARE REQUIRED | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST INFORMATION PLACARD | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | PROVIDE FULL INTERIOR ACCESS- BASEMENT AREAS, 2ND FL FRONT REAR UNITS , 1ST REAR UNIT | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH - EXTERIOR PORCH SYSTEM NOT ORIGINAL , SEE DEFICIENT THE FOLLOWING DEFECTS. 1 COLUMNS NOT ANCHORED AT BOTTOM 2. COLUMN LAP JOIST TOE NAILED WITH INSUFFICIENT BOLTS 3 BEAMS WITH OUT TIE STRAPS AT WALL OF FIRE CUT, SEE UNSEAL BEAM POCKETS AT BRICK WALL. 4 STRINGERS TOE NAILED AT ANCHOR ENDS TOP AND (BOTTOM) 5 RIM JOIST TOE NAILED, SOUTH 1ST TO 2ND RESTING ON A CRUMBLING CONCRETE FENCE SECTION. WEAK HAND RAILS GRADE TO 2ND FLOOR. 3 GUARD RAIL END AT WALL WITH CUT NAILS 4 PICKETS ANCHORED OUT SIDE OF BOTTOM RAIL , EASY TO KICK OFF POSITION 7 PLANS AND PERMITS REQUIRED. | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | SOUTH EAST BASEMENT DOOR WITH GAPS AROUND FRAME | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR WELL HAND AND GUARD RAIL PICKETS SPACED GREATER THAN 4 INCHES B) LOOSE TREADS , BOUNCY BOARDS | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THRU OUT 1ST FLOOR UNIT | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LITES THUR OUT 1ST FLOOR UNIT - | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE ALL PAINTED AND DEFECTIVE RECEPTACLES THRU OUT 1ST FLOOR UNIT AND OTHER TYPICAL UNITS IN BUILDING | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS AND BATHROOMS- 1ST FLOOR UNIT AND OTHER TYPICAL UNITS IN BUILDING 18.27.210-8 | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
PROVIDE WEATHER PROOF BOXES , LITES AND FITTINGS , THRU OUT PORCH AREAS ON SOUTH SIDE OF BUILDING 18-27-110.11 | 649 N SPAULDING AVE | COMPLAINT | FAILED | View | |
SECURE RACEWAY | PROPERLY SUPPORT CONDUIT RUNS THRU OUT PORCH AREA'S | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTORS TO CORRECT VIOLATIONS | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING. BUILDING NOT REGISTERED 4 OR MORE UNITS | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | PORCH SYSTEM. INSTALL MISSING STRAPS/HARDWARE AT FLOOR JOIST AND 6X6 LOOKOUTS. INSTALL MISSING HANDRAIL AT FRONT CONCRETE STAIRS GRATE TO BASEMENT | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY ARRANGE FOR INTERIOR INSPECTION | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO MAIN FRONT ENTRANCE ON EXTERIOR | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE REAR PORCH EXTERIOR LIGHT FIXTURES BASEMENT TO 2ND FLOOR ALL BOXES AND FIXTURES MUST BE WEATHERPROOF | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REMOVE ABANDONED CONDUIT AT SIDE OF BUILDING ABOVE SIDE ENTRANCE. (18-27-110.12(E)) | 649 N SPAULDING AVE | COMPLAINT | FAILED | View | |
REPAIR PORCH SYSTEM | FOOTING INSPECTION FAILED - FOOTING DETAILED ON PLANS HAS NO FOOTING, NO REBAR - ON DETAIL - ONLY 12" X 48" PEDELSTAL - CONCRETE BLOCK ROUND IN COLUM - 6X6 COLUMNS - TWISTED AND OVER NOTCHED, RETAINING WALL BOWING | 649 N SPAULDING AVE | PERMIT | PASSED | View |
FILE BLDG REGISTRATION | BLDG. - NOT REGISTERED FROM 2012 THRU 2013 | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - OWNER'S I.D. SIGN - MISSING | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SOUTH AT 1 AND 2 / REAR PORCH DECKING - BARBECUE GRILLS. | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2-STORY / SIDE PORCH - 6X6 COLUMNS TWISTED, OVER NOTCHED AND ERECTED ON BOWING AND CRUMBLING RETAINING WALL. PORCH ONLY SEPARATED FROM ADJOINING BUILDING WITH ONLY 6 INCHES GAP - FIRE HAZARD. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION - PARAPET WALL OUT OF PLUMB AND BULGING OUT. | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | PERIMETER OF BUILDING ENCIRCLED WITH CHAIN LINK OR IRON FENCING NO PERMIT ON FILE | 649 N SPAULDING AVE | COMPLAINT | FAILED | View |