Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 4:53 PM
PIN: 16014000200000
Property Address: 2701 W DIVISION ST
City - Zip: CHICAGO - 60622
2023 Property Class: 397
2023 Township: 77 - West Chicago
2023 Neighborhood: 77030
2023 Tax District: 77050
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 33 Violations
Violation Inspector Comments Address Category Status View
STOP ALL CONSTRUCTION WORK PERFORMED WITHOUT A PERMIT PER SECTION 13-12-080; 13-32-035. 2701 W DIVISION ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ACQUIRE PLANS AND PERMIT FOR INTERIOR BUILDOUT OF FIRST FLOOR COMMERCIAL SPACE. 2701 W DIVISION ST COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 2005-2008 2701 W DIVISION ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 1990 THRU 2011 2701 W DIVISION ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR 1148 EXTERIOR DOOR;WOOD SPLIT 2701 W DIVISION ST PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER 1146-48 INTERIOR STAIRS AND 2701 INTERIOR STAIR;CRACKED AND BUCKLING PLASTER 2701 W DIVISION ST PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION 2ND FLR.WINDOW PANE;BROKEN 2701 W DIVISION ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 1148 INTERIOR STAIRS TREADS,LANDING;BROKEN AND WEAK 2701 W DIVISION ST PERIODIC FAILED View
PERMIT REQUIRED NO PERMITS FOR 2701 1ST FLR.DRYWALL REPAIRS 2701 W DIVISION ST PERIODIC FAILED View
INT WALL/CEILING CHIP PLASTER 1146-48 INTERIOR STAIRS AND 2701 INTERIOR STAIR;CRACKED AND BUCKLING PLASTER 2701 W DIVISION ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 1148 INTERIOR STAIRS TREADS,LANDING;BROKEN AND WEAK 2701 W DIVISION ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 1990 THRU 2011 2701 W DIVISION ST PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR NO ENTRY TO 4TH FLR. 2701 W DIVISION ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 1990 THRU 2011 2701 W DIVISION ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. REAR YARD - LOCKED GATES, UNABLE TO INSPECT REAR PORCHES. 2701 W. / 4TH FLOOR UNIT - NO ENTRY, UNABLE TO VERIFY COMPLAINT OF ASBESTOS. 2701 W DIVISION ST PERIODIC FAILED View
REPAIR LINTELS NORTH ELEVATION / GRADE TO 4TH FLOOR / ALL WINDOWS' METAL LINTELS - RUSTED AND BENT. PERMIT ONLY REQUIRED FOR METAL LINTELS REPLACEMENT. 2701 W DIVISION ST PERIODIC FAILED View
PARAPET EAST ELEVATION / PARAPET WALL - SEVERELY LEANING INWARDS. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. 2701 W DIVISION ST PERIODIC FAILED View
REPAIR COPING EAST ELEVATION / ABOVE ENTRANCE TO 1146 N. / COPING STONE - SEVERELY SHIFTING AND BULGING OVER PUBLIC WAY. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. 2701 W DIVISION ST PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION / STONEWORK ABOVE 3RD FLOOR - SEVERELY BULGING AND SHIFTING OVER PUBLIC SIDEWALK. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. 2701 W DIVISION ST PERIODIC FAILED View
PROTECT SIDEWALK DURING CONST PROVIDE PROTECTIVE CANOPY OVER PUBLIC SIDEWALK. PERMIT ISSUED BY DEPARTMENT OF TRANSPORTATION REQUIRED FOR SUCH INSTALLATION. 2701 W DIVISION ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR INTERIOR ALTERATIONS TO INCLUDE BUT NOT LIMITED TO:INTERIOR BUILD OUT OF FIRST FLOOR COMMERCIAL SPACE. 2701 W DIVISION ST COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT FINE/PENALTY ASSESSED FOR WORK DONE WITHOUT A PERMITSECTION 13-12-080, 13-32-035. 2701 W DIVISION ST COMPLAINT FAILED View
UNLAWFUL TO DO WORK W/O PERMIT UNLAWFUL TO DO WORK WITHOUT A PERMIT 2701 W DIVISION ST COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU INSTALL SINGLE LAYER OF 5/8 INCH TYPE X DYWALL AT BASEMENT CEILING. EXISTING CONDITION IS EXPOSED WOOD FRAMING. 2701 W DIVISION ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL INSTALL SELF CLOSING, SELF LATCHING CLASS B FIRE DOOR ASSEMBLY AT FIRST FLOOR STAIRWELL OPENING TO BASEMENT.EXISTING DOOR IS NON RATED WOOD PANEL DOOR. 2701 W DIVISION ST COMPLAINT FAILED View
PROVIDE ONE HOUR FIRE RESISTIVE SEPARATION AT FIRST FLOOR RESTAURANT AND DWELLING UNIT ON SECOND FLOOR. EXISTING CONDITION IS EXPOSED WOOD FRAMING. PER SECTION 13-56-280 2701 W DIVISION ST COMPLAINT FAILED View
HEATING PLANT ENCLOSURE PROVIDE ONE HOUR FIRE RESISTIVE ENCLOSURE AT FIRST FLOOR FURNACE. EXISTING ROOM IS NOT FIRE RESISTIVE CONSTRUCTION. 2701 W DIVISION ST COMPLAINT FAILED View
HEATING PLANT/BOILER ROOM DOOR INSTALL SELF CLOSING, SELF LATCHING CLASS B FIRE DOOR ASSEMBLY AT FIRST FLOOR FURNACE ROOM. EXISTING DOOR IS NON RATED WOOD PANEL CONSTRUCTION. 2701 W DIVISION ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR INSTALL 36 INCH WIDE DOOR AT EAST WALL EXIT DOOR OPENING. EXISTING DOOR IS 30 INCHES WIDE. 2701 W DIVISION ST COMPLAINT FAILED View
DOOR SWING IN DIR. OF TRAVEL FRONT AND REAR EXIT DOORS SWING INWARD. EXISTING SEATING FOR 58 PERSONS REQUIRES EXIT DOORS TO SWING OUT. 2701 W DIVISION ST COMPLAINT FAILED View
REPAIR STOOP AT FRONT ENTRANCE THERE IS A 10 INCH HIGH STEP FROM GROUND LEVEL TO FIRST FLOOR RESTAURANT. STEP SHOULD BE MAXIMUM OF 7-1/2 INCHES HIGH. IN AN ATTEMPT TO CORRECT THIS PROBLEM A SHORT RAMP WAS BUILT WITHIN THE ENTRANCE VESTIBULE CREATING ANOTHER PROBLEM OF A STEEPLY INCLINED RAMP SANDWICHED BETWEEN THE INNER AND OUTER VESTIBULE DOORS. REMOVE RAMP AND INSTALL AN INTERMEDIATE STEP. 2701 W DIVISION ST COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT BEFORE STARTING REPAIR WORK. 2701 W DIVISION ST COMPLAINT FAILED View
OPEN 2701 W DIVISION ST PERMIT FAILED View