Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | SR#07-00745260 NO OWNER ID SIGN POSTED | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION: WASHED OUT MORTAR, 1ST, 2ND LEVELS | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION: MISSING GUARD RAIL AT GRADE LEVEL | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALKWAY BROKEN, CRACKED, UNEVEN AND REAR SECTION MISSING | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: FOUNDATION STATUS UNKNOWN, INADEQUATE BEAM TO COLUMN CONNECTION, SEE SCABBED LUMBER FOR SUPPORT OF 6X6 BEAM, MISSING BOLTS ON ALL BEAM TO COLUMN, TOP OF STRINGERS, CONNECTIONS, SEE SCABBED LUMBER SUPPORTING WINDER STAIRS AT 1ST TO 2ND, RAILS ARE LOOSE, PICKETS ARE SPACED AT 5 INCHES APART AT SOME LOCATIONS; SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE OR REPAIR REAR PORCH | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | BASEMENT FRONT ENTRY DOOR: MISSING DEADBOLT LOCK | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING LUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT PERMIT | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' | BASEMENT HEIGHT IS ONLY 6 FEET, 10 INCHES | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION: PARAPET WALL-WASHED OUT MORTAR | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRS: MISSING SMOKE DETECTOR | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | BASEMENT FLOOR BY KITCHEN: VERY WEAK, UNSTABLE | 1617 S HAMLIN AVE | COMPLAINT | FAILED | View |