Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNER ID SIGN POSTED | 2333 S CALIFORNIA AVE | COMPLAINT | PASSED | View |
REPAIR LINTELS | NORTH ELEVATION LINTELS ROTTED SAGGING | 2333 S CALIFORNIA AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH COLUMNS NOT SET ON PORCH FOOTINGS ROTTED COLUMNS ROTTED DECKING, EXTENSIVE SCABBING. ROTTED BEAMS THAT SUPPORT 2ND FLOOR. SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH. | 2333 S CALIFORNIA AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO VERIFY DETECTORS OCCUPANCY AND INSPECT FRONT STAIRWALL. | 2333 S CALIFORNIA AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGH THE BASEMENT AREA. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | CONCRETE STEP AT NORTHWEST CORNER BROKEN CONCRETE. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND WEST WALLS BOWING WALLS, MISSING MORTAR CAUSING DANGEROUS AND HAZARDOUS CONDITION. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | OBTAIN ENGINEER'S REPORT FOR EXTERIOR WALLS NORTH AND WEST ELEVATIONS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NORTH AND WEST EXTERIOR WALL: PERMIT AND LICENSED MASONRY CONTRACTOR REQUIRED. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | BIKES STORED AT 2ND FLOOR LANDING BLOCKING EGRESS FROM 2ND FLOOR FRONT DWELLING UNIT. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | OPEN JOISTS OBSERVED THROUGHOUT BASEMENT AREA. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT SEPARATION | NO HEATING PLANT ENCLOSURE IN THE BASEMENT AREA. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR OBSERVED IN THE BASEMENT AREA. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 1ST FLOOR REAR DWELLING UNIT, BEDROOM DOOR HUNG UPSIDE DOWN. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | CANOPIES REQUIRED FOR SIDE BOTH NORTH AND WEST ELEVATIONS. (120 FEET NORTH AND 30 FEET WEST ELEVATIONS). | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | DOOR TO ROOF MISSING. CARDBOARD AND TARP INSTALLED. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO KITCHEN FAUCET, LAVATORY AND TOILET - 1ST FLOOR EAST UNIT. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TRAP | REMOVE PVC P-TRAP KITCHEN SINK AND LAVATORY - 1ST FLOOR EAST UNIT. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | WATER LEAKING 1ST FLOOR INTO BASEMENT AT 4" STACK. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | REMOVE RAW SEWAGE IN BASEMENT - DANGEROUS AND HAZARDOUS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES ALL THREE WATER HEATERS BASEMENT. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | PROVIDE PROPER TYPE COVERS FOR OPEN PANELS WITH EXPOSED LIVE PARTS IN BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES DUE TO INSUFFICIENT RECEPTACLES AND EXTENSION CORD USE THROUGHOUT 1ST FLOOR REAR UNIT AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES TO REAR PORCH LIGHT AND THROUGHOUT 1ST FLOOR REAR UNIT WITH BARE WIRES TO LIGHT FIXTURES - DANGEROUS AND HAZARDOUS CONDITION. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE ALL DEFECTIVE AND PAINTED RECEPTACLES THROUGHOUT THE REAR 1ST FLOOR UNIT AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE ALL DEFECTIVE LIGHTS THROUGHOUT BASEMENT, 1ST FLOOR REAR, INTERIOR STAIRWAY AREAS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE LIGHTS FOR ALL BASEMENT AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT CONDUIT RUNS THROUGHOUT ALL BASEMENT AREAS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
GROUNDING RECEPTACLES | PROVIDE GROUND TYPE RECEPTACLES THROUGHOUT 1ST FLOOR REAR AREA UNIT AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOP AREAS, BATHROOMS, LAUNDRY AREAS AND BASEMENT AREAS. (18-27-210.8) | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS AND APPROVED RACEWAY FOR ALL REAR PORCH AREAS AND LIGHT IN 1ST FLOOR REAR BATHROOM NEED TO BE WEATHERPROOF. (18-27-110.11) | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View | |
PROVIDE PUBLIC METER, PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, GARAGE AND BASEMENT AREAS. (18-27-210.25) | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View | |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. (13-12-360) | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View | |
APPLIANCE INSIGHT DISCONNECT | WALL MOUNTED HEATERS REQUIRE A DISCONNECT MEANS IN 1ST FLOOR REAR UNIT AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
FOLLOW APPROVED PLANS | 2333 S CALIFORNIA AVE | PERMIT | PASSED | View | |
FOLLOW APPROVED PLANS | CORRECTIONS HAVE BEEN MADE. | 2333 S CALIFORNIA AVE | PERMIT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIRS GRADE TO BASEMENT LOOSE TREADS, MISSING RISERS. STAIRS GRADE TO 2ND FLOOR MISSING SPINDLES. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE ALL DEFECTIVE AND EXCESSIVE USE OF ARMORED CABLE THROUGHOUT ALL BASEMENT AREAS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANES, BROKEN GLASS BLOCKS NORTH AND WEST ELEVATIONS. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL PVC WASTE PIPING IN BASEMENT. | 2333 S CALIFORNIA AVE | COMPLAINT | FAILED | View |