Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR | #1 BOILER CASING. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
OWNER OR LICENSED CONTRACTOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View | |
REPAIR INTERIOR WALLS/CEILING | 9177 ROOM 107 BATHROOM SHOWER MILDEW, LIVING ROOM UNFINISHED DRYWALL WORK. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
DWELLING CLEAN AND SANITARY | 9177 ROOM 107 INTERIOR WALLS UNSANITARY. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
REPAIR FLOOR | 9177 ROOM 107 LIVING ROOM FLOOR TILES/ STAINED, UNSANITARY. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
CARB MONOX DETECT IN RESID | 9177 ROOM 107 NO CARBON MONOXIDE DETECTOR. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
CLASS B DOOR IN STAIRWELL | 9141 / 2ND FLOOR WEST STAIRWAY DOOR - MISSING HANDLE SET. DOOR DOES NOT LATCH. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR | FIRE BOX REFRACTORY AND CASING #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
ADJUST BOILER BURNER | #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
FOUND NO VIOLATIONS AS OF DATE | NO APPARENT VIOLATTIONS AT TIME OF INSPECTION | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
OWNER OR LICENSED CONTRACTOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View | |
INTERNAL | #2 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLAINT INSPECTION: CLOSE OPEN MODERNIZATION PERMIT #100870196 AND #100870190 WITH ANDERSON ELEVATOR FOR BOTH 9141 AND 9177 S SOUTH CHICAGO BUILDINGS | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLAINT INSPECTION: #1 ELEVATOR (9177) - REPAIR DOOR CLOSE BUTTON AND ADJUST DOOR CLOSE TIMER. AT EACH LANDING, DOORS REMAIN OPEN UNTIL ELEVATOR DOOR OPEN TIMES OUT. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR OR REPLACE ELEVATOR EMERGENCY PHONES AND PROPERLY PROGRAM TO A 24HR ANSWERING SOURCE CARS 1&2. | 9177 S SOUTH CHICAGO AVE | PERIODIC | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CODE DATA PLATES ON ELEVATOR CONTROLLERS WITH CODE DATES. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATAGORY 5 SAFETY TESTS CARS 1&2. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY LABEL ELEVATOR MACHINE ROOM DISCONNECTS TO SHOW MAINLINE AND LIGHTS FOR CARS 1&2. | 9177 S SOUTH CHICAGO AVE | PERIODIC | CLOSED | View |
OWNER OR LICENSED CONTRACTOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View | |
LEAKING BOILER TUBES | #9 AJAX 02 HWB #61209. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE LOAD TEST ON CAR #2 | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FOR 2016. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPLACE | OPERATING & LOW FIRE LIMIT CONTROLS #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
REPLACE | BENT REFRACTORY GUIDE RAILS #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
HYDROSTATIC TEST | #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
REPAIR DOOR, INT. | 9TH TO 1ST FLOOR ALL TRASH CHUTE DO NOT LATCH WHEN DOOR IS PULL DOWN. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
STOP LEAKING WATER | BASEMENT WATER PIPES LEAKING WATER TO THE FLOOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | BASEMENT EXTERIOR DOOR ALL DO NOT HAVE SELF CLOSERS | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 9177 / APT. 301 / KITCHEN WALL - WATER DAMAGE WITH BUBBLING PAINT. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | 9141 / 3RD FLOOR TRASH CLOSET DOOR - HITS ON SIDE JAMB. UPPER CORNER OF DOOR DAMAGED. 6TH AND 7TH FLOOR TRASH CHUTE DOORS - DO NOT CLOSE. 9177 /8TH FLOOR / TRASH CHUTE - DOES NOT CLOSE. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | APARTMENT # 910 - HOT WATER PROVIDED AT 80F. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE MINIMUM VENT QUANTITY | 18-28-403 MECHANICAL VENTILATION * PROVIDE VENTILATION TO INSURE MINIMUM AIR QUANTITIES | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN MECH. VENT SYSTEM | 18-28-102 APPLICABILITY * MAINTAIN MECHANICAL VENTILATION EQUIPMENT IN GOOD REPAIR AND OPERATE TO PROVIDE ADEQUATE VENTILATION | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
NO ENTRY | (VT 3021) 18-28-4 VENTILATION PRESSURE EQUALIZATION 4.CORRIDOR MAKE UP AIR SYSTEM FOR RESIDENTIAL BUILDING OVER 55FT IN HEIGHT SHALL BE SIZED TO EQUAL THE TOTAL OF TOILET KITCHEN AND DRYER AIR EXHAUST REQUIREMENTS | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 ELEVATORS: MOUNT ABC FIRE EXTINGUISHER IN MACHINE ROOM | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: CORRECT TOP OF CAR BARRICADES | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MISSING FIRE SERVICE KEYS FOR ALL FIRE KEY BOXES | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: PROVIDE RED/WHITE STRIPES AROUND COMPS AND COUNTERWEIGHT IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 #2 ELEVATORS: PROVIDE EMERGENCY COMMUNICATIONS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: REPAIR FIRE SERVICE PHASE II NOT RECALLING TO EGRESS FLOOR. | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #1: REMOVE OLD WIRES AND CAP OFF REAR WALL AT BOTTOM LANDING | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH ELEVATORS: PROVIDE DISCONNECT FEED LABELS FOR MAIN LINE AND CAB LIGHTS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CAULK HOISTWAY, MACHINE ROOM, AND PIT WHERE PENETRATIONS/HOLES EXIST | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COVER ALL UNUSED HOLES IN MACHINE ROOM FLOOR | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | IDENTIFY NEW PANELS AND ELECTRIC CIRCUITS FOR CAB LIGHTS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE PERMANENT AMBIENT TEMPERATURE CONTROL IN MACHINE ROOM TO MEET NEW ELEVATOR EQUIPMENT REQUIREMENTS SPECIFICATIONS TO AVOID CONSTANT SHUTDOWNS. MACHINE ROOM IS TOO HOT AND WILL NOT BE INSPECTED UNTIL SOLUTION IS IN PLACE | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: REPAIR FIRE SERVICE PHASE II NOT RECALLING TO EGRESS FLOOR. | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 #1 CAR: REPIPE GOVERNOR TO REMOVE TRIP HAZARD | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: TEST FAIDS; EM POWER; LOSS OF COMMUNICATION | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141: PROVIDE MISSING FIRE SERVICE KEYS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: COVER UNUSED HOLES IN MACHINE ROOM FLOOR AND PROVIDE KICK ANGLES AROUND CABLE SLOTS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: COVER UNUSED HOLES IN MACHINE ROOM FLOOR AND PROVIDE KICK ANGLES AROUND CABLE SLOTS | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: PATCH HOISTWAY INCLUDING PIT AREA WITH 2HR FIRE RATED MATERIAL | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: BOTH ELEVATORS: PROVIDE DISCONNECT FEED LOCATION LABEL WITH LOCATION, PANEL NAME, AND CIRCUIT NUMBER(S) | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: CLEAN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 ELEVATORS: LABEL PIPE IN MACHINE ROOM | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: MOUNT ABC FIRE EXTINGUISHER IN MACHINE ROOM | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: PROVIDE "DANGER COUNTERWEIGHT" SIGN IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
REPAIR DOOR HARDWARE | 5N STAIRWELL DOOR - SLAMS. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 3RD FLOOR HALLWAY - LOOSE VINYL BASEBOARD. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | NORTH ELEVATION - MISSING SEVERAL WINDOW SCREENS. | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9171 ALL ELEVATORS: PROVIDE PANCAKE PUSH/PULL PIT STOP SWITCHES | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9177 #1 ELEVATOR: REPLACE DOOR DETECTOR TO BRING ELEVATOR INTO FULL WORKING CONDITION THEN RESCHEDULE FULL LOAD TEST | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9177 BOTH ELEVATORS: SCHEDULE FULL LOAD WITH 125% TEST | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: CLEAN CONTROLLER WIRING TO WORKMANSHIP LIKE MANNER | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: PROVIDE COUNTERWEIGHT RUNBY SIGN IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: CLEAN CONTROLLER WIRING TO WORKMANSHIP LIKE MANNER | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 #1 ELEVATORS: PROVIDE PERMANENT MEANS TO ACCESS UNDERSIDE OF ELEVATOR | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: CORRECT TOP OF CAR BARRICADES | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BOTH ELEVATORS: PROVIDE COUNTERWEIGHT RUNBY SIGN IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: PROVIDE INDEPENDENT NON-GFCI SUMP OUT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 ELEVATORS: TEST FAIDS; EM POWER; LOSS OF COMMUNICATION | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 ELEVATORS: LABEL DRAIN PIPE IN MACHINER ROOM BEHIND MACHINE ROOM DOOR | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141-9177 BOTH ELEVATORS: CLEAN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH ELEVATORS: PROVIDE RUNBY SIGNS | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH ELEVATORS: PROVIDE CODE COMPLIANT PIT LADDERS AND REMOVE OLD REAR PIT LADDER | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #1: CHANGE TOP OF CAR DATA PLATE TO MATCH NEW CAB WEIGHT | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH: CAULK HOISTWAY, MACHINE ROOM, AND PIT WHERE PENETRATIONS/HOLES EXIST | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH ELEVATORS: PROVIDE DISCONNECT FEED AND HIGH VOLTAGE LABELS FOR MAIN LINE AND CAB LIGHTS AND REMOVE OLD DISCONNECTS | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH: PERMANENTLY IDENTIFY NEW PANELS AND ELECTRIC CIRCUITS FOR CAB LIGHTS | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #2: CAULK SUMP PIPING IN PIT WITH 2HR FIRE RATED MATERIAL | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE AND MOUNT SERVICED FIRE EXTINGUISHER IN MACHINE ROOM | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #2: PROVIDE CODE COMPLIANT TOE GUARD | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | APPLY FOR VARIANCE DUE TO LOSS OF PERMISSIBLE CLEARANCE OF EQUIPMENT IN MACHINE ROOM | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE DEDICATED CIRCUIT FOR PIT SUMP PUMP. CANNOT BE ON GFCI | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH ELEVATORS: PROVIDE AND MAINTAIN WORKING EMERGENCY PHONE LINES FOR USE OF BOTH ELEVATOR. #2(02368) IS RED TAGGED FOR NO USE & NOT TO BE PLACED IN SERVICE UNTIL CITY OF CHICAGO OKAYS USE | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE WORKING SUMP PUMP THAT IS CAPABLE TO REMOVE 3000 GAL/HR PER ELEVATOR | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | BOTH: PROVIDE COUNTERWEIGHT GUARD | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COVER ALL UNUSED HOLES IN MACHINE ROOM FLOOR AND WALLS | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | #2: WALL OFF VOID IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE MACHINE ROOM DOOR SIGNAGE | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE AND MAINTAIN PROPER CLEARANCE FOR MACHINES. CLOSE OFF ACCESS TO NON ELEVATOR EQUIPMENT ONLY! | 9177 S SOUTH CHICAGO AVE | PERMIT | FAILED | View |
REMOVE WATER FROM PIT | REMOVE STANDING WATER IN PIT | 9177 S SOUTH CHICAGO AVE | PERMIT | CLOSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | ALL ELEVATORS IN BUILDING (9141 & 9177): PROVIDE AND MAINTAIN WORKING EMERGENCY PHONE LINES FOR USE OF #1 ELEVATOR IN 9141 AND #2 IN 9177. BOTH UNITS ARE RED TAGGED FOR NO USE & NOT TO BE PLACED BACK IN SERVICE UNTIL CITY OF CHICAGO OKAYS USE. RED TAG #02377 FOR THE 9141 SIDE AND #20368 FOR THE 9177 SIDE. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REPLACE | GAS TRAIN #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
REPLACE | DAMAGED REFRACTORY #1 BOILER. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
REPL DEFECTIVE BATHROOM FLOOR | TUB ROOMS PIPES STICKING OUT FROM FLOORS. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROPERLY NUMBER AND LABEL ELEVATOR CONTROLLERS TO MATCH ELEVATOR NUMBERS IN CARS 1&2. | 9177 S SOUTH CHICAGO AVE | PERIODIC | CLOSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 17 FL EXIT LIGHT NOT WORKING | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | BASEMENT HALLWAYS MISSING FIRE DOORS | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 9TH TO 1ST FLOOR NO HOT WATER | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
PROVIDE COLD WATER TO FICTURES | 9TH TO 1ST FLOOR NO COLD WATER | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT TRASH ROOM NO SMOKE DETECTOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | CLOSE OPEN MODERNIZATION PERMIT #100870196 AND #100870190 WITH ANDERSON ELEVATOR FOR BOTH 9141 AND 9177 S SOUTH CHICAGO BUILDINGS | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | AGAIN - PROVIDE A WORKING EMERGENCY ELEVATOR PHONE LINE FOR ALL FOUR ELEVATORS WITH 24HR PHONE MONITORING | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
OWNER OR LICENSED CONTRACTOR | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View | |
STEAM BOILER PERMIT | LOCHINVAR HOT WATER BOILERS. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
WATER HEATER PERMIT | LOCHINVAR HOT WATER BOILERS. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
PRESSURE VESSEL PERMIT | ARMSTRONG EXPANSION TANKS, LOCHINVAR HOT WATER TANKS, ARMSTRONG SEPRATOR. | 9177 S SOUTH CHICAGO AVE | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 AND 9177 ELEVATORS (ONGOING ISSUE): PROVIDE ELEVATOR'S WITH OPERATIONAL EMERGENCY PHONES AND PROGRAM TO 24HR MONITORING SERVICE. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | 9141 BUILDING: BRING ELEVATOR #1 MAKE NECESSARY REPAIRS TO BRING UNIT INTO FULL WORKING CONDITION | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | 9137 / 9TH FLOOR WEST STAIRWAY DOOR - MISSING LOCKSET. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | ALL TRASH CHUTE DOORS - DAMAGED HANDLES OR CLOSERS. MOST ARE OPEN AND NOT OPERABLE. 9137 / 5TH FLOOR LAUNDR YROOM DOOR - DAMAGED JAMB PREVENTING DOOR FROM CLOSING. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 9177 / 9TH FLOOR LAUNDRY ROOM / SMOKE DETECTOR - OUT OF DATE FROM 2010. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BUILDING THROUGHOUT - MICE. MOUSE HOLES - OBSERVED AT HALLWAY AND STAIRWAY FLOOR RADIATORS. 9177 APT 711 HAS MOUSE HOLES UNDER KITCHEN CABINET AND IN CLOSET. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PARAPET | BUILDING / PARAPETS - CRACKED AND SPALLED MASONRY | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | HALLWAYS AND COMMUNITY AREA - STORING SHOPPING CARTS. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | 9177 / ROOF IS CURRENTLY HAVE WORK DONE WITHOUT A PERMIT.PERMIT IS NOW REQUIRED. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | BUILDING AT VARIOUS LOCATIONS / SCREENS - TORN. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
HOLDOPEN DEVICE ON APT DOOR | 9137 APTS 301 AND 304 - HELD OPEN. APT 110 HAS TOE KICK ( DANGEROUS AND HAZARDOUS ). | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
HOLDOPEN DEVICE, STAIR 3+ FLRS | 1ST FLOOR HALLWAY DOORS AND ALL LAUNDRY ROOM DOORS - HELD OPEN WITH TOE KICKS. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
PROVIDE | ALL LEVELS STAIRWELL IDENTIFICATIONS ARE AWAY FROM STAIRWELL DOOR PER CODE 4(13-76-075). | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | COMPLAINT INSPECTION: #1 ELEVATOR (9141) - PROVIDE A WORKING EMERGENCY ELEVATOR PHONE LINE WITH 24HR PHONE MONITORING. NOT OPERATIONAL DURING INSPECTION. | 9177 S SOUTH CHICAGO AVE | COMPLAINT | FAILED | View |