Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS THROUGHOUT GARDEN UNIT, INSTALL WORKING SMOKE DETECTORS THROUGHOUT PROPERTY. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | LIGHT FIXTURE AT SIDE ENTRY NOT SECURELY ATTACHED TO BUILDING. SECURE LIGHT FIXTURES IN APPROVED MANNER WHERE REQUIRED THROUGHOUT PREMISES. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | LEAKING WATER PIPING THROUGHOUT PREMISES HAS CAUSED A DANGEROUS AND HAZARDOUS CONDITION OF CEILING COLLAPSING AT THE GARDEN LEVEL UNIT. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE ANY REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT AT GARDEN AND WHERE REQUIRED IN TYPICAL AREAS THROUGHOUT PREMISES. NEW SERVICE AND MISCELLANEOUS ELECTRICAL WORK GARDEN. PREVIOUS PERMITS NOT INSPECTED. (13-12-380) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR STAIR | FRONT OF PROPERTY EAST ELEVATION IRON STAIRS NOT SUFFICIENTLY SECURED AT THE BASE CAUSING THE STAIRS TO SHIFT IN DOWNWARD POSITION ON THE LEFT SIDE SHOWING SIGNS OF FAILING. (HAZARDOUS CONDITIONS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | MISSING METALLIC STRAINER AT GARDEN LEVEL PORCH FLOOR DRAIN. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | SERVICE RISER COMPLETELY UNSUPPORTED AND FALLING AWAY FROM BUILDING. PARTIALLY DAMAGED METER ENCLOSURE. SERVICE DISCONNECTS NOT GROUPED. NO COMMON METER. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | UNSANITARY CONDITIONS THROUGHOUT GARDEN UNIT AT PROPERTY. CURRENTLY ANIMAL FECES ON BEDROOM FLOOR. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
REMOVE | REMOVE ALL TIRES BEING STORED AT REAR OF PROPERTY (FIRE HAZARD) CURRENTLY MOUNDS OF TIRES BEING STORED WITHIN REAR YARD WEST ELEVATION AT PROPERTY CAUSING (DANGEROUS AND HAZARDOUS CONDITIONS) (15-4-090) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | GARDEN UNIT CEILINGS COLLAPSING THROUGHOUT, WALLS WATER DAMAGED BUCKLING IN VARIOUS LOCATIONS THROUGHOUT. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL AT NORTH ELEVATION MISSING MORTAR WITH SPALLING BRICK. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | OPEN WIRING HANGING AT MISSING SMOKE DETECTOR LOCATION AT GARDEN MECHANICAL ROOM. REMOVE OPEN WIRING WHERE REQUIRED THROUGHOUT PREMISES. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | CATCH BASIN AT WEST EXTERIOR IS FULL TO THE BRIM AND HAS CREATED DANGEROUS AND HAZARDOUS FLOODING TO THE GARDEN UNIT. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS, TO REPAIR WATER DAMAGED ELECTRICAL EQUIPMENT AT REAR GARDEN MECHANICAL ROOM AND PORCH AREA AND WHERE REQUIRED IN TYPICAL AREAS THROUGHOUT BUILDING, AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES AND EQUIPMENT AT GARDEN AND WHERE REQUIRED IN TYPICAL AREAS THROUGHOUT PREMISES. WATER DAMAGE VISIBLE VARIOUS AREAS GARDEN. NEW SERVICE AND MISCELLANEOUS ELECTRICAL WORK GARDEN. PREVIOUS PERMITS NOT INSPECTED. (13-12-360) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT AT 1ST FLOOR. (13-12-380) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
RATS | RAT INFESTATION THROUGHOUT PROPERTY. CURRENTLY GARDEN UNIT SEVERE INFESTATION OF RATS AND RODENTS. (HAZARDOUS CONDITIONS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | SPACE HEATERS USED AS MEANS OF HEATING GARDEN UNIT CAUSING (DANGEROUS AND HAZARDOUS CONDITIONS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED FLEXIBLE WATER SUPPLY PIPING AND PLASTIC PEX PIPING THROUGHOUT PREMISES. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
ROACHES | ROACH INFESTATION THROUGHOUT GARDEN UNIT. (EXTERMINATOR REQUIRED). | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | CATCH BASIN AT WEST EXTERIOR IS MISSING A COVER EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS FALL CONDITION. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALLOW FOR A FULL INTERIOR INSPECTION OF THE ENTIRE PROPERTY. NO ENTRY TO 1ST FLOOR, GARDEN UNIT ENTRY ONLY AT TIME OF INSPECTION. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT SEPARATION | HEAT PLANT ENCLOSURE WITHIN GARDEN UNIT MISSING SECTIONS OF FIRE SEPARATION THROUGHOUT. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | GARDEN UNIT CEILINGS MISSING SECTIONS OF FIRE RATED MATERIAL, CURRENTLY CEILING MISSING SECTIONS OF DRYWALL, 1-HOUR FIRE RATED MATERIAL REQUIRED THROUGHOUT. (DANGEROUS AND HAZARDOUS CONDITIONS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS THROUGHOUT GARDEN UNIT. INSTALL WORKING CARBON MONOXIDE DETECTORS THROUGHOUT PROPERTY. (DANGEROUS AND HAZARDOUS) | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | INSUFFICIENT PANEL SCHEDULE GARDEN REAR. PROVIDE ACCURATE PANEL SCHEDULES WHERE REQUIRED THROUGHOUT PREMISES. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
WORKING SPACE | DEBRIS AND STORAGE IN FRONT OF ELECTRICAL PANEL AT GARDEN REAR. PROVIDE WORKING SPACE AT ELECTRICAL EQUIPMENT WHERE REQUIRED THROUGHOUT PREMISES. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | IRON PICKET FENCE AT PROPERTY OVER 5 FT. REMOVE, REDUCE, HEIGHT, OR OBTAIN PERMIT TO STAND AS IS. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM. | 2242 S SAWYER AVE | COMPLAINT | FAILED | View |