Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CIRCUIT ONE UNIT ONLY | MIXED CIRCUITS BETWEEN UNITS ANDPROVIDE PUBLIC PANEL AND METERING FOR BUILDING COMMON AREA LOADS 18-27-210.25 | 5430 W SCHOOL ST | COMPLAINT | PASSED | View |
SUPPLEMENTAL GROUND | INSTALL SUPLEMENTAL GROUND FOR BUILDING SERVICE 18-27-250.64(B) | 5430 W SCHOOL ST | COMPLAINT | PASSED | View |
REPLACE************** | BOND COLD WATER GROUNDING ELECTRODE CONDUCTOR TO NEUTRAL AT ALL SERVICE DISCONNECTS. 18-27-250.24 | 5430 W SCHOOL ST | COMPLAINT | PASSED | View |
STRAP SERVICE CONDUIT | SRAP SERVICE RISER TO STRUCTURE 18-27-110.12 | 5430 W SCHOOL ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING/ OWNERS ID SIGN- MISSING. | 5430 W SCHOOL ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 5430 W SCHOOL ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PUBLIC ON COMMON AREA LIGHTING SHALL NOT BE SUPPLIED FROM EQUIPMENT THAT SUPPLIES AND INDIVIDUAL SWELLING UNIT 1827-210.25 | 5430 W SCHOOL ST | COMPLAINT | PASSED | View |