The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNAPPROVED CORDS | REMOVE CORDS THROUGHOUT OFFICE AND GARAGE LOCATION FEEDING PERMANENT EQUIPMENT AND SIGNAGE | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
CORD WIRED EQUIPMENT | REMOVE CORD FROM HOT WATER HEATER IN GARAGE DANGEROUS HAZARDOUS. | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | MISSING FIRE EXTINGUISHERS 14X-5-0504.5 DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FENCE | IRON FENCE AND MAKESHIFT FENCE AT SOUTH ELEVATION BY ALLEY OVER 5' REMOVE, REDUCE HEIGHT OR OBTAIN PERMIT TO KEEP AS IS 14A-4-404.7 | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | INSTALL MISSING MAT ON SERVICE PANEL IN GARAGE AREA (EXPOSED LIVE PARTS) DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | PEX TUBING USED FOR WATER PIPPING THROUGHOUT PREMISE MUST BE REMOVED AND CORRECTLY PIPED TO CITY OF CHICAGO PLUMBING CODE DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD ADDITIONAL RECEPTACLES IN ORDER TO ELIMINATE OVER USE OF CORDS THROUGHOUT GARAGE AND OFFICE AREAS DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | EMPLOY LICENSED AND BONDED PLUMBING CONTRACTOR FOR PLUMBING WORK TO BE PERFORMED TO ADDRESS PLUMBING VIOLATIONS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SEPARATE CIRCUIT FOR APPLIANCE | ADD CIRCUIT IN ORDER TO SERVE ELECTRIC HOT WATER HEATER IN GARAGE AREA WHICH HAS A TEMPORARY CORD DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS 14X-5-504.8 DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | NO COLD WATER FROM POTABLE WATER SOURCE TO ALL FIXTURES DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT FOR PLUMBING WORK TO BE PERFORMED | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SYSTEM III | INSTALL SYSTEM III EMERGENCY LIGHTING AND EXIT SIGNS THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | VERIFY GROUNDING ELECTRODE CONDUCTORS FOR BOTH SERVICES TO BUILDING NO COLD WATER THROUGHOUT GARAGE AND NO ACCESS TO REMAINING PART OF BUILDING | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI PROTECTION TO ALL RECEPTACLES IN COMMERCIAL GARAGE LOCATION DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS 14X-5-504.9 DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | SUBMIT REVISED PLANS FOR ALTERATION OF POTABLE WATER SUPPLY SYSTEM FOR ENTIRE LOCATION | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | NO HOT WATER TO HAND SINK IN BATHROOM | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
OUTDOOR ARMORED CABLE | REMOVE BX WIRING SERVING OUTDOOR SIGN ON SW CORNER ON DIVISION ST DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | NO CAST IRON COVER FOR THREE COMPARTMENT CATCH BASIN LOCATED IN AUTO REPAIR SHOP | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL MISSING COVERS THROUGHOUT GARAGE AREA SPECIFICALLY AT SERVICE PANEL LIFTS AND OIL HEATER CONTROL PANEL DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND FLOOR OR REAR GARAGE SOUTH ELEVATION 14A-1-104.7 | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | SECURE AND PROPERLY STRAP ALL CONDUITS THROUGHOUT GARAGE AREA WALLS AND CEILING DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ELECTRICAL PERMIT IN ORDER TO CORRECT ALL ELECTRICAL VIOLATIONS (14A-4-404.6) | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | HEATING UNIT IN FRONT OFFICE NOT PROPERLY VENTED TO EXTERIOR 14X-3-305.1 DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | FLOOR DRAIN IN BATHROOM IS DEFECTIVE AND NOT INSTALLED CORRECTLY | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
NO USE SECNDY WTR FOR COOLING | STOP USING SECONDARY WATER SUPPLY SYSTEM THAT IS NOT INSTALLED CORRECTLY TO CITY OF CHICAGO PLUMBING CODE DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THERE IS AN ADDITION BEING BUILT ON 2ND FLOOR,STOP WORK UNTIL PLANS AND PERMITS ARE PROVIDED 14A-4-401.1 | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TOILET SEAT | NO OPEN FRON-NON ABSORBENT TOILET SEAT USED FOR PUBLIC OR EMPLOYEE BATHROOM AT LOCATION | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
APPLIANCE INSIGHT DISCONNECT | INSTALL DISCONNECT SWITCHES TO SERVICE AUTOMOBILE LIFTS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHTING FIXTURES IN OFFICE AREA WHERE LENSES ARE MISSING AND LAMPS FALLING OUT OF FIXTURE DANGEROUS AND HAZARDOUS | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR MASONRY THERE ARE STRESS FRACTURE AT NORTHWEST ELEVATION (CMU BLOCK) OF FRONT BUILDING AND WEST ELEVATION OF THE REAR BUILDING 14X-3-303.1.1 | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | ARRANGE FOR INSPECTION 18-28-106.1 SR # 18-03034252 | 4857 W DIVISION ST | COMPLAINT | PASSED | View |
MAINTAIN MECH. VENT SYSTEM | MAINTIN MECH EQUIPMENT IN GOOD REPAIR 18-28-102 "WOOD BURNING FIREPLACE TO BE REMOVED" | 4857 W DIVISION ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | EXTERIOR ALTERATIONS TO A 2 STORY NON RESIDENTIAL MASONRY BUILDING INCLUDING BUT NOT LIMITED TO ERECTING A WOOD STRUCTURE WITH ROOF AT SECOND FLOOR AT SOUTH ELEVATION OF BUILDING WITHOUT PLANS SUBMITTED OR A PERMIT OBTAINED | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL A BUILDING PERMIT IS OBTAINED 14A-3-306-1 14A-4-411-1 14A-4-401-1 | 4857 W DIVISION ST | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE ADEQUATE HEAT IN WORK SPACE 68 DEGREE'S MIN 13-196-750 | 4857 W DIVISION ST | COMPLAINT | PASSED | View |