FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 2015 THRU 2017. | 3251 E 91ST ST | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | 3251 E./ -GARDEN APARTMENT - MISSING FRONT SMOKE DETECTOR. | 3251 E 91ST ST | COMPLAINT | FAILED | View |
EXIT THROUGH BEDROOM/BATHROOM | APARTMENTS 3251 E./ -GARDEN APT; 1ST FLOOR;2ND FLOOR, 3RD FLOOR.APARTMENTS 3253 E./ 1ST FLOOR, 2ND AND 3RD FLOOR. - REAR EXIT IS THRU REAR BEDROOM; PLANS AND PERMIT REQUIRED TO PROVIDE PROPER REAR MEANS OF EGRESSS. | 3251 E 91ST ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | FRONT INTERIOR STAIRWAY, 3RD FLOOR LANDING - BROKEN FLOOR TILE. | 3251 E 91ST ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS - RUSTED BEAMS. | 3251 E 91ST ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | BUILDING AT VARIOUS LOCATIONS / SCREENS - TORN. | 3251 E 91ST ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION 3 STORY WOOD PORCH / COLUMN HALF LAP JOINTS - MEASURE 12 INCHES AND ARE FASTENED WITH ONLY 2 BOLTS. HALF LAP JOINTS ARE LOCATED AT TOP OF GUARDRAILS. SOME STRINGERS - SHOW SIGNS OF ROT AND DECAY. SOME STRINGERS - DOUBLED UP WITH 2X4'S. 2ND FLOOR HANDRAIL - LOOSE AND DETACTED. STAIR STRINGERS FROM TREADS TO BOTTOM OF HANDRAILS - GAPS UP TO 10 INCHES WIDE. STAIR TREADS - LOOSE. TOP RAILS - ROTTING AND DETERIORATED. GUARDRAILS - MISSING PICKETS. ROOF HATCH - MISSING. STEEL HARDWARE - RUSTED. PERMIT REQUIRED FOR PORCH REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. NORTH ELEVATION / 1 STORY STEEL AND WOOD PORCH / STEEL STRUCTURE ESPECIALLY AT UNDERSIDE OF BEAMS - RUSTED AND DETERIORATED WITH LOOSE AND BUBBLING STEEL. STAIR TREADS - LOOSE. PLANS AND PERMIT REQUIRED FOR STEEL AND WOOD PORCH REPAIRS. SUBJECT TO INSPECTION AND APPROVAL BY IRON BEREAU. | 3251 E 91ST ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT AT APT G FOR THE BACK DOOR BEING BROKEN. | 3251 E 91ST ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH - STORING BBQ GRILLS AND GARBAGE. | 3251 E 91ST ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH, SOUTH AND WEST ELEVATIONS / EXTERIOR WALLS - WASHED OUT MORTAR. | 3251 E 91ST ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS - RUSTED BEAMS | 3251 E 91ST ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH; TREADS SPLIT, SWAY BRACE BROKEN, STRINGERS SPLIT, DECK BOARDS SPLIT AND BUCKLING UP AND SPLIT. | 3251 E 91ST ST | PERIODIC | FAILED | View |