The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR DOWNSPOUT | SOUTH ELEVATION/DOWNSPOUT - LOOSE AND PULLING AWAY FROM EXTERIOR WALL.EAST ELEVATION - SECTION MISSING. | 1849 S AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION/EXTERIOR WALL - SPALLING BRICKS WITH CRACKED MASONRY. | 1849 S AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST ELEVATION/EAVES - FASCIA BOARD LOOSE AND PULLING FROM EXTERIOR WALL. | 1849 S AVERS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1 STORY WOOD FRONT PORCH - 6X6 COLUMNS, ROTTING WOOD. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT COLUMNS WITH NAILS ONLY. TREADS AND RISERS - WORN OUT, CRACKED AND WEAK.1 STORY WOOD REAR PORCH - 6X6 COLUMNS ERECTED ON TOP OF CONCRETE RETAINING WALL, NOT ANCHORED AND TWISTED. UNDERSIZED 4X4 BEAMS SPAN 7 FEET AND TOE NAILED TO COLUMNS. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT COLUMNS WITH NAILS ONLY. FLIGHT OF STAIRS FROM GRADE TO 1ST FLR - WEAK AND UNSTABLE. RAILING SECTIONS - FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS AND SCREWS ONLY; PICKETS MISSING. PERMIT ONLY REQUIRED TO REPAIR FRONT AND REAR PORCHES. | 1849 S AVERS AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | BASEMENT ENTRANCE DOOR - MISSING DOOR KNOB. | 1849 S AVERS AVE | COMPLAINT | FAILED | View |
ARRANGE FOR RE-INSPECTION | NO SHOW FOR A SCHEDULED APPOINTMENT | 1849 S AVERS AVE | PERMIT | FAILED | View |
OPEN | 1849 S AVERS AVE | PERMIT | PASSED | View |