ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS UNABLE TO INSPECT INTERIOR STAIRWAYS-REAR YARD-NO ENTRY: UNABLE TO INSPECT REAR PORCHES. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | 6336-TOP AT STAIRWELL UNDER SKYLIGHT | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 6336-TOP OF STAIRWELL AT CEILING HAS WATER DAMAGE NORTH PORCHES-HAND AND GUARDRAILS ARE WEAK AND THE LOW-42" MINIMUM HEIGHT STRINGERS AND LEDGERS-MISSING BOLTS REPAIR PERMIT REQUIRED | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | 6338 REAR PORCH LANDINGS USED AS STORAGE | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
INT WALL/CEILING CHIP PLASTER | 6336 APARTMENT 1B/BEDROOM CEILING-LOOSE | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | 6336 BASEMENT CEILING LARGE SECTION OF MISSING PLASTER AND EXPOSED LATHE | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
PROV HOT WTR TO ALL FIXTURES | 6336 APARTMENT 1B-KITCHEN AND BATHROOM-LOW PRESSURE ON HOT WATER | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING-MANAGEMENT/OWNER'S ID SIGN-INCOMPLETE | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
MICE/RODENTS | MICE INFESTED | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCK | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING-NOT REGISTERED FROM 1990 THRU 2009 | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION , AT THIRD FLOOR , ABOVE 6338 FRONT ENTRY DOORWAY , LIMESTONE WINDOW HEAD STONES DISPLACED , MOVED OUT , WITH OPEN MORTAR JOINTS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THREE NORTH THREE STORY WOOD PORCHES ALL HAVE SIMILAR DEFECTS AND REQUIRE PLANS AND PERMITS TO REPAIR . UNKNOWN FOUNDATIONS STATUS . FLOOR JOIST SCABBED AND DOUBLED .STAIR TREADS ONLY NINE INCHES WIDE , ALL TREADS WORN AND WEATHERED . DECKING BOARDS WORN AND UNDERSIZED ..NORTH CENTER STAIRWAY FROM GRADE TO FIRST FLOOR , LEANING SEVERELY . WINDER STAIRS HAVE NO TREAD SUPPORT AND RISER BOARDS ARE UNDERSIZED AND ONLY NAILED TO COLUMN . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
ROACHES | ROACHES THRUOUGHOUT BUILDING. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT OPERATING 6334 UNIT 3B. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS EXPIRED IN STAIRWELL. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION CORRIGATED FIBER GLASS PORCH SIDING WITH LOOSE AND MISSING SECTIONS. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH EAST PORCH 2X8 JOISTS SPAN 15' AT 1 AND 2. BUCKLED DECKING VARIOUS LOCATIONS. SINGLE 2X8 BEAMS AT WEST END IN MASONRY POCKETS AT CORNER WITH NO VISIBLE MASONRY ANCHORS EXCEPT AT 3 WHERE TAP CONS AND A 5"X5"X1" 3/16" CORNER ANGLE USED TO ANCHOR BEAM TO MASONRY. WORN TREADS ONLY 9 1/4" DEEP. ROTTING POST AND STRINGER COLUMN AT 2, AT SAME LOCATION STRINGER IS ROTTED. BEAM AND JOIST SEPARATING AT 2. CONNECTION MADE WITH NAILS ONLY. ROTTING BEAM AT SAME LOCATION. BEAM AT 2 AT WEST END SPLIT AT MASONRY CONNECTION. OUTSIDE 2X8 BEAMS SUPPORTING DECKS AND STRINGERS AND RAILS ARE 2X8 AND SPAN 6' 6". NORTH MIDDLE PORCH WORN TREADS 9 1/4" DEEP. LOOSE RAIL AT GROUND. SINGLE 2X8 STRINGER HEADER JOISTS SPAN 6' 6". SOME BUCKLED DECKING. ROTTED AND CRACKED STRINGER HEADER JOIST AT LANDING BEFORE 3. NORTH WEST PORCH WORN TREADS 9 1/4" DEEP. 6X6 COLUMN WITH SIGNIFICANT RATT REPAIRED WITH PUTTY. BEAMS ANCHORED WITH NAILS ONLY. NO VISIBLE ANCHORING FOR BEAMS AT MASONRY CONNECTION. 2 X 10 BEAM SPANS 11' AND SUPPORTS STRINGERS, JOISTS, HEADERS, POSTS AND RAILS. COLUMN SPLICE AND BEAM NOTCH IN CLOSE PROXIMITY AT WINDER BEFORE 1, AND SPLICE AND NOTCH IN SAME LOCATION AT WINDER BEFORE 2. 4X4 CENTRAL STRINGER COLUMN WITH BUTT JOINT CONNECTIONS, AND WITHIN 6' OF ANOTHER. SAME 4X4 COLUMN EXTENDS APPROX. 24'. SINGLE 2X8 STRINGER HEADER JOISTS SPAN 7'. OBTAIN COMPLETE PLANS AND PERMITS. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
ROACHES | ROACHES THRUOUGHOUT BUILDING. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT OPERATING 6334 UNIT 3B. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . NO ENTRY ON COMPLAINT OF BEDBUG AND MICE INFESTATIONS OR 2014 ANNUAL INSPECTION . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | BUILDING - POSTED ADDRESS NOT VIEWABLE FROM STREET . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS , WINDOW SCREENS , TORN , LOOSE AND MISSING . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | BUILDING - FRONT YARDS OVERGROWN SHRUBS AND TRASH . SHRUBS OVERGROWN ONTO CITY WALK , WALKWAYS AND PATHWAYS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | THREE FRONT ENTRY DOORS AND FRAMES , ROTTED AT BASES WITH FLAKING PAINT . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | FRONT 6334 N. FRONT ENTRY , NORTH SIDELIGHT WINDOW GLASS , LOOSE AND SAGGING IN FRAME . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND WEST ELEVATIONS , GUTTERS AND DOWNSPOUTS RUSTED WITH FLAKING PAINT . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | NORTH AND WEST ELEVATIONS , DOWNSPOUTS , SMASHED , DENTED AND DISCONNECTED AT GRADE . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
EXT. WALL. FIRE RESISTANCE | NORTHWEST THREE STORY WOOD FRAME PORCH , EXTERIOR WALLS CLAD IN PLASTIC CORRUGATED PANELS OF IMPROPER FIRE RESISTANCE AND INSTALLED ON SUBSTANDARD WALL FRAMING WITHOUT OBTAINING PERMITS . FIRE AND SAFETY HAZARD TO TENANTS AND OCCUPANTS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION , AT THIRD FLOOR , ABOVE 6338 FRONT ENTRY DOORWAY , LIMESTONE WINDOW HEAD STONES DISPLACED , MOVED OUT , WITH OPEN MORTAR JOINTS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THREE NORTH THREE STORY WOOD PORCHES ALL HAVE SIMILAR DEFECTS AND REQUIRE PLANS AND PERMITS TO REPAIR . UNKNOWN FOUNDATIONS STATUS . FLOOR JOIST SCABBED AND DOUBLED .STAIR TREADS ONLY NINE INCHES WIDE , ALL TREADS WORN AND WEATHERED . DECKING BOARDS WORN AND UNDERSIZED ..NORTH CENTER STAIRWAY FROM GRADE TO FIRST FLOOR , LEANING SEVERELY . WINDER STAIRS HAVE NO TREAD SUPPORT AND RISER BOARDS ARE UNDERSIZED AND ONLY NAILED TO COLUMN . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS EXPIRED IN STAIRWELL. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | THREE NORTH THREE STORY WOOD PORCHES ALL HAVE SIMILAR DEFECTS AND REQUIRE PLANS AND PERMITS TO REPAIR . UNKNOWN FOUNDATIONS STATUS . FLOOR JOIST SCABBED AND DOUBLED .STAIR TREADS ONLY NINE INCHES WIDE , ALL TREADS WORN AND WEATHERED . DECKING BOARDS WORN AND UNDERSIZED ..NORTH CENTER STAIRWAY FROM GRADE TO FIRST FLOOR , LEANING SEVERELY . WINDER STAIRS HAVE NO TREAD SUPPORT AND RISER BOARDS ARE UNDERSIZED AND ONLY NAILED TO COLUMN . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT OPERATING 6334 UNIT 3B. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND WEST ELEVATIONS , GUTTERS AND DOWNSPOUTS RUSTED WITH FLAKING PAINT . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | NORTH AND WEST ELEVATIONS , DOWNSPOUTS , SMASHED , DENTED AND DISCONNECTED AT GRADE . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
EXT. WALL. FIRE RESISTANCE | NORTHWEST THREE STORY WOOD FRAME PORCH , EXTERIOR WALLS CLAD IN PLASTIC CORRUGATED PANELS OF IMPROPER FIRE RESISTANCE AND INSTALLED ON SUBSTANDARD WALL FRAMING WITHOUT OBTAINING PERMITS . FIRE AND SAFETY HAZARD TO TENANTS AND OCCUPANTS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION/WINDOW SILLS-WASHED OUT MORTAR. | 6334 N ARTESIAN AVE | PERIODIC | PASSED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED 2011 THROUGH 2014 YEARS . | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |
ROACHES | ROACHES THRUOUGHOUT BUILDING. | 6334 N ARTESIAN AVE | PERIODIC | FAILED | View |