PIN: 16262040060000
Property Address: 3339 W CERMAK RD
City - Zip: CHICAGO - 60623
2023 Property Class: 522
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77079
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL NORTH ELEVATION WASHED OUT MORTAR ( INCLUDING BEHIND METAL PANEL AT GRADE.BRICK SOLDIER COURSE IS SHIFTING ABOVE LINTEL.UNABLE TO VERIFY LITEL ( BEAM ) CONDITION. PERMIT REQUIRED IF REPLACING LINTEL.SOUTH ELEVATION - CRACKED CONCRETE COAT. 3339 W CERMAK RD COMPLAINT FAILED View
REPAIR ROOF ROOF - TORN ROOFING MATERIAL. 3339 W CERMAK RD COMPLAINT FAILED View
WORK NOT ALLOWED ATTIC - REMOVE ALL ELECTIC FIXTURES AND ELECTRIC OUTLETS INSTALLED WITHOUT A PERMIT.REAR STORAGE AREA A FLOOR DECK BUILT (ABOVE 1ST FLOOR )WITH 2"X6" JOISTS SPANNING 17'-2" WITH NO INTERMEDIATE SUPPORT, PLANS AND PERMIT REQUIRED. 3339 W CERMAK RD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ORIGINAL ATTIC STORAGE SPACE - ALTERED INTO A LIVINGSPACE ( ATTIC HAS FURNITURE, INCLUDING A BED ) - NO PLANS AND PERMIT OBTAINED. 3339 W CERMAK RD COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION - BROKEN WINDOW PANE. 3339 W CERMAK RD COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT EAST ELEVATION - GUTTER IS SAGGING.EAST ELEVATION - MISSING DOWNSPOUT. BL00831 3339 W CERMAK RD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS ATTIC LIVING SPACE - MISSING SMOKE DETECTOR. 3339 W CERMAK RD COMPLAINT FAILED View
DEFECTIVE POWER SERVICE SE CABLE NOT PERMITTED ON COMMERCIAL BUILDING 18-27-338.2 3339 W CERMAK RD COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND NO SUPPLEMENTAL GROUND 3339 W CERMAK RD COMPLAINT FAILED View
EXPOSED WIRING REAR, D&H 3339 W CERMAK RD COMPLAINT FAILED View
PROPER SIZE OCP #10 ON 60 AMP, #14 ON 20AMP, D&H 3339 W CERMAK RD COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION NO SPLICING IN PANEL, OPEN PANEL D&H 3339 W CERMAK RD COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION,MASONRY WALL-BULGING OUTWARD. 3339 W CERMAK RD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS,UNABLE TO VERIFY COMPLAINT OF REAR EXIT-NO STAIRCASE. 3339 W CERMAK RD COMPLAINT FAILED View
REPAIR LINTELS SOUTH WOOD LINTEL - SAGGING. 3339 W CERMAK RD COMPLAINT FAILED View
DEBRIS, EXCESSIVE ATTIC STORAGE SPACE - JUNK ACCUMULATION. 3339 W CERMAK RD COMPLAINT FAILED View
INSTALL COVERS REAR, D&H 3339 W CERMAK RD COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD-OLD CAR TIRES STORED. 3339 W CERMAK RD COMPLAINT FAILED View