Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ ENTRY REFUSED. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAY. UNABLE TO INSPECT REAR ENCLOSED PORCH. NOTE: DURING INSPECTION - OBSERVED 3 ADULT MALES AND 3 ADULT FEMALES GOING IN AND OUT OF BUILDING. 1 MALE STATED THAT HIS SISTER OWNS THE BUILDING AND REFUSED ENTRY. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND SOUTH ELEVATIONS /ROOF GUTTERS - EXCESSIVE JUNK AND DEBRIS.EAST ELEVATION /PORCH ROOF GUTTERS AND DOWNSPOUT - MISSING.SOUTH ELEVATION /ROOF GUTTERS - LOOSE AND HANGING. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION /1ST. AND 2ND. FL. WINDOWS - BOARDED UP. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
CHIMNEY HEIGHT | EAST CHIMNEY /TOO LOW - ONLY 2 BRICKS HIGH ABOVE ROOF.MASONRY PERMIT REQUIRED. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | EAST CHIMNEY CAPPING - MISSING. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION /1 STORY WOOD PORCH WITH ROOF.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE AND SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN. COLUMNS /SOUTHEAST COLUMN - MISSING, SCABBED WITH 2X4 ERECTED ON SOIL.LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS/SCREWS ONLY.ROOF BEAMS /STACKED ON TOP OF COLUMNS, FASTENED WITH NAILS/SCREWS ONLY. DECK JOISTS /UNDERSIZED 2X6 DECK JOISTS. FASTENED TO HEADERS, WITH NAILS ONLY. STRINGERS /UPPER ENDS OF STRINGERS, FASTENED WITH NAILS /SCREWS ONLY. RAILINGS /STAIR RAILING SECTIONS - LOOSE AND PULLING. ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY.PERMIT REQUIRED.REAR ELEVATION /1STORY OVERSIZED WOOD PORCH ATTACHED TO ENCLOSED PORCH.FOUNDATIONS /COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN.LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS/SCREWS ONLY.DECK JOISTS /UNDERSIZED DECK JOISTS. FASTENED TO HEADERS, WITH NAILS ONLY.STRINGERS /UPPER ENDS OF STRINGERS, FASTENED WITH NAILS /SCREWS ONLY. STAIRS /RISER HEIGHT NOT UNIFORMED.RAILINGS /GUARD RAILING AND STAIR RAILING SECTIONS - LOOSE AND PULLING. DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING. ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY.PLANS AND PERMIT REQUIRED.REAR 1 STORY WOOD ENCLOSED PORCH.FOUNDATIONS /COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN.PERMIT REQUIRED.NOTE: UNDERSIDE OF DECK JOISTS COVERED WITH PLYWOOD - UNABLE TO INSPECT CONDITIONS. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | GABLE ROOF [AT EAST] /NORTH AND SOUTH ELEVATIONS - LARGE HOLES.FLAT ROOF [AT WEST] /COVERED WITH RIPPED TARP. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | FRONT AND REAR ELEVATIONS /EXCESSIVE JUNK AND DEBRIS. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
STOP SMOKE, NOXIOUS ODORS | FRONT ELEVATION [AT PORCH] /NOXIOUS [CAT URINE] ODOR. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | NORTH ELEVATION /WINDOW FRAMES - ROTTED. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |
PROVID SELF CLSING SCREEN DVCE | FRONT ELEVATION /METAL SCREEN DOOR - RUSTED, OFF HINGES. | 5602 S PERRY AVE | COMPLAINT | PASSED | View |