Last Modification Date: 2024-08-30 @ 3:57 PM
PIN: 16093000030000
Property Address: 331 N CENTRAL AVE
City - Zip: CHICAGO - 60644
2023 Property Class: 318
2023 Township: 77 - West Chicago
2023 Neighborhood: 77013
2023 Tax District: 77029
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 158 Violations
Violation Inspector Comments Address Category Status View
OBTN PERMIT FOR PLUMBING WORK (18-29-106.1) PULL PERMIT. 331 N CENTRAL AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR 1(4-332-010-100). HIRE LICENSED AND BONDED PLUMBING CONTRACTOR. 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING (18-29-102.3) REPLACE DEFECTIVE PIPING ON WATER HEATERS (THIS INCLUDES VALVE ON THE HOT WATER SIDE ON THE WATER HEATER, PROPERLY INSTALLING RETURN LINES TO WATER HEATERS AND INSTALLING A PUMP ON RETURN LINES 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING (18-29-712.3.2) THE SUMP PIT SHALL BE FITTED WITH A GAS TIGHT REMOVABLE COVER AND VENTED PROPERLY. (THIS PIT IS OPEN AND THE DISCHARGE PIPING IS HOSE NOT PIPE) 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING (18-29-712.2) A CHECK VALVE IS REQUIRED ON THE WAST DISCHARGE - THERE IS NONE ON THIS PIPE. 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING (18-29-712.4.1) PUMP IS UNDERESIZED FOR THE PIT AND THE AMOUNT OF LIFT REQUIRED. 331 N CENTRAL AVE COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY (18-29-602), (18-29-608) PROVIDE REDUCED PRESSURE ZONE (R.P.Z) ON COLD WATER MAKE UP TO BOILER. 331 N CENTRAL AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR STAIRS(INTERIOR)-GARBAGE CANS BLOCKING EGRESS, MANY DWELLING UNITS - BURGULAR BARS OUTSIDE PADLOCK HASPS 331 N CENTRAL AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG RECHARGE AND TAG ALL FIRE EXTINGUISHERS 331 N CENTRAL AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BUILDING THROUGHOUT-REPAIR EXIT SIGNS 331 N CENTRAL AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 337 STORE. MAINTAIN 3' AISLE-STOCK HAMPERS EGRESS 331 N CENTRAL AVE COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED BUILDING THRUOUT-REPAIR EXIT SIGNS 331 N CENTRAL AVE COMPLAINT FAILED View
HEATING PLANT/BOILER ROOM DOOR 337 STORE-FURNACE ACCESS DOOR CLASS B WITH CLUSTER 331 N CENTRAL AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK (18-29-106.1)PULL PERMIT 331 N CENTRAL AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR HIRE LICENSED & BONDED PLUMBING CONTRACTOR 331 N CENTRAL AVE COMPLAINT FAILED View
RESTORE EXIT AND EM THRUOUT 331 N CENTRAL AVE COMPLAINT FAILED View
INSTALL TRAP,WASTE,VENT PIPES (18-29-966-1.3), (18-29-1001.1) INSTALL WASTE, VENT, TRAP & WATER FOR MOP SINK OR SERVICE SINK IN COMMERCIAL SPACES 335 & 337 N. CENTRAL AVE, ALSO PROVIDE SAME FOR CONDENSATION LINES FROM UNIT IN BOTH COMMERCIAL SPACES. 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING (18-29-102.3) INSTALL DIE - ELET. UNIONS WERE NEEDED 331 N CENTRAL AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING (18-29-102.3) REPLACE ILLEGAL MATERIAL IN CAST IRON STACK. (LOOKS LIKE FLUE PIPE) 331 N CENTRAL AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS (18-29-102.3) REMOVE ALL PVC PIPING, TRAPS AND FITTING THROUGHOUT THE BUILDING 331 N CENTRAL AVE COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT (18-29-420.3) PROVIDE OPEN FRONT TOILET SEAT IN UNITS AT 335 & 337 N. CENTRAL. (COMMERCIAL) 331 N CENTRAL AVE COMPLAINT FAILED View
REPL DEFECTIVE BATHROOM FLOOR (13-196-540F), (18-29-405.2.1) REPLACE DEFECTIVE BATH ROOM FLOOR WITH NONABSORBENT, WATER IMPERVIOUS EASILY CLEANABLE MATERIALS (IN COMMERCIAL UNIT 335 & 337 N. CENTRAL AVE.) 331 N CENTRAL AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2004 THROUGH 2006 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRONT ENTRY DOOR: BROKEN PANE 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL FRONT ENTRY BY DOOR: WASHED OUT MORTAR 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR FLOOR VESTIBULE: LOOSE,BROKEN GRANITE BASEBOARDS 331 N CENTRAL AVE PERIODIC FAILED View
CARPETING HALLWAY CARPET: LOOSE & FRAYED; FILTHY UNSANITARY 331 N CENTRAL AVE PERIODIC FAILED View
PROVIDE BASEMENT: PIPES LOOSE, FRAYED ASBESTOS WRAP-REMOVE SEAL 331 N CENTRAL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE BASEMENT WALLS: GRAFFITI 331 N CENTRAL AVE PERIODIC FAILED View
RATS BASEMENT: RATS 331 N CENTRAL AVE PERIODIC FAILED View
RAT STOP AROUND EXTERIOR RAT PROOF BUILDING 331 N CENTRAL AVE PERIODIC FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT: HOLES IN FIREWALL 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR REAR BOILER ROOM: DOOR RUSTED THRU-REPLACE 331 N CENTRAL AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY STAIRWELLS BLOCKED BY GARBAGE CONTAINERS 331 N CENTRAL AVE PERIODIC FAILED View
UNINTERRUPTED EXIT AT GRADE SOME APT. UNIT WITH BURGLAR BARS 331 N CENTRAL AVE PERIODIC FAILED View
HOLDOPEN DEVICE, STAIR 3+ FLRS FRONT STAIRWELL DOORS: BLOCKED OPEN 331 N CENTRAL AVE PERIODIC FAILED View
REPL DEFECTIVE BATHROOM FLOOR MOST KITCHENS: TORN, MISSING TILES 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS MOST UNITS: NO SMOKE DETECTORS 331 N CENTRAL AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID BOILER ROOM: NO CO2 DETECTOR 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM STAIRWELL: RAILS MISSING PICKETS 331 N CENTRAL AVE PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL STAIRWELL DOORS NOT RATED 331 N CENTRAL AVE PERIODIC FAILED View
OPEN BOILER ROOM: INSTALL TEMPERATURE GAUGES ON ALL WATER HEATERS (18-29-102.3) 331 N CENTRAL AVE PERIODIC FAILED View
RMV DFT PIPE,FITTING,FIXTURE REMOVE VALVES ON HOT SIDE OF WATER HEATER IN BOILER ROOM (18-29-102.3) 331 N CENTRAL AVE PERIODIC FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMITS (18-29-106.1) 331 N CENTRAL AVE PERIODIC FAILED View
PRV WATER AT PLUMBING FIXTURE LOW WATER PRESSURE THRU-OUT ENITRE BUILDING (7-28-060) 331 N CENTRAL AVE PERIODIC FAILED View
SYSTEM III INSTALL EMERGENCY SYSTEM III, EXISTING SYSTEM NOT COMPLETE, ADDITIONAL BATTERY PACKS AND EXIT SIGNS NEEDED THRU-OUT BUILDING AND BASEMENT 331 N CENTRAL AVE PERIODIC FAILED View
18-27-215.5, PROVIDE LOAD CALCULATIONS FOR SERVICE FEEDERS 331 N CENTRAL AVE PERIODIC FAILED View
UNAPPROVED EM REMOVE UNAPPROVED WIRING TO BATTERY PACK, 1ST FL & 3RD FL AND MIDDLE STAIRWELL 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL COVERS INSTALL COVERS ON OPEN JUNCTION BOXES IN BOILER ROOM & BASEMENT 331 N CENTRAL AVE PERIODIC FAILED View
SEE INSPECTOR COMMENTS 18-27-210-8, INSTALL GFCI IN WET LOCATIONS THRU-OUT BUILDING 331 N CENTRAL AVE PERIODIC FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING ON EXTERIOR, WEST ELEVATION 331 N CENTRAL AVE PERIODIC FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURES ON CORRIDORS, BASEMENT, 1ST & 2ND & 3RD FLOORS 331 N CENTRAL AVE PERIODIC FAILED View
LIVE FRONT SWITCHBOARD REMOVE LIVE FRONT SERVICE DISTRIBUTION 331 N CENTRAL AVE PERIODIC FAILED View
SEE INSPECTOR COMMENTS ILLUMINATE BASEMENT THRU-OUT BUILDING 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED 4TH FLOOR NW STAIRWAY - EXIT SIGN FACING WRONG WAY 331 N CENTRAL AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS - TORN OR MISSING SCREENS 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED #335 STOREFRONT - FRONT EXIT - EXIT SIGN NOT WORKING AT TIME OF INSPECTION 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR LINTELS WEST - LINTEL - RUSTING ABOVE RESIDENTIAL DOORWAY AT NW ENTRANCE 331 N CENTRAL AVE PERIODIC FAILED View
CUT OR REMOVE HIGH WEEDS EAST - WEEDS THRU-OUT REAR 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - WINDOW SCREENS - TORN OR MISSING THRU-OUT 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR EAST - REAR ENTRY DOOR - RUSTING 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST - REAR ENTRY DOOR - DOOR KNOB MISSING 331 N CENTRAL AVE PERIODIC FAILED View
ILLUMINATE EXIT AREAS EAST - REAR EXIT - EXTERIOR ILLUMINATION MISSING 331 N CENTRAL AVE PERIODIC FAILED View
FIRE EXTNGSHR REQ, NONRESDNTL #331 1/2 STOREFRONT - FIRE EXTINGUISHER - EXPIRED 331 N CENTRAL AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE EAST - TRASH, DEBRIS, GARBAGE, JUNK, STOVE AT REAR 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN WINDOW EAST/1ST, 2ND FLOOR - WINDOW FRAMES, TRIM - ROTTING; PAINT PEELING 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL EXIT SIGN #331 1/2 STOREFRONT - EXIT SIGNS MISSING AT FRONT AND REAR EXITS;#335 STOREFRONT - EXIT SIGN MISSING AT REAR EXIT. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL/#337 - DECORATIVE STONE MISSING AT STOREFRONT ENTRANCE; SHEET METAL USED TO COVER AREA 331 N CENTRAL AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND #331, #335 1/2, AND #337 STOREFRONTS - VACANT 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN WINDOW EAST ELEVATION - ROTTED WINDOW FRAMES WITH PEELING PAINT 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRONT ENTRANCE AND COURTYARD DOORS - RUSTED AND WARPED . 331 N CENTRAL AVE PERIODIC FAILED View
DOOR SWING IN DIR. OF TRAVEL BASEMENT - REAR NORTH CORRIOR DOORS SWING AGAINST DIRECTION OF TRAVEL . EXIT SIGN DIRECTS EGRESS IN THAT PATHWAY 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR COMPLAINANT NO LONGER A RESIDENT AT THIS ADDRESS. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND ALL STOREFRONTS. UNVERIFIED DETECTORS AND CONDITIONS. 331 N CENTRAL AVE PERIODIC FAILED View
NO POSTED ADDRESS #331 1/2 STOREFRONT - ADDRESS NOT POSTED 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL ALL ELEVATIONS - FRACTURES AND ERODED MORTAR AT VARIOUS LOCATIONS'WEST ELEVATION - FRACTURES, LOOSE AND SPALLED STONES AT VARIOUS LOCATIONS. LOOSE ROUNDED STONE COLUMN NEEDS TO BE ABATED ASAP,PERMIT FOR REPAIRS REQUIRED. 331 N CENTRAL AVE PERIODIC FAILED View
OBTAIN PERMIT BEFORE SIGN WORK ONE PROJECTING PUBLIC 4 X 4' SIGN READS "QUICK CHECK TAX SERVICE 773-378-2901, 13-20-520 AND 13-20-550 331 N CENTRAL AVE COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA OBTAIN DECOMISION PERMITT TAKE CAR OUT OF SERVICE . 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA IF ELEVATOR WAS DECOMMISSIONED ACCORDING TO CODE PROVIDE DECOMISSION PERMIT. 331 N CENTRAL AVE PERIODIC FAILED View
BLOCKED FIRE DOOR 331,335,337 -NON RESIDENT UNITS,REAR EXITS BLOCKED WITH STOCK. 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO BASEMENT 2ND,3RD FLOOR TO CHECK OCCUPANCY DETECTORS AND COMPLAINT OF UNIT 307-BATHROOM CEILING FELL DOWN . 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED. 331 N CENTRAL AVE PERIODIC FAILED View
BLOCKED FIRE DOOR 331,335,337 -NON RESIDENT UNITS,REAR EXITS BLOCKED WITH STOCK. 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY TO BASEMENT 2ND,3RD FLOOR TO CHECK OCCUPANCY DETECTORS AND COMPLAINT OF UNIT 307-BATHROOM CEILING FELL DOWN . 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED.FOR 1990 THRU 2011 331 N CENTRAL AVE PERIODIC FAILED View
MAINT VERTICAL WHEELCHAIR LIFT REPAIR NON FUNCTIONING LIFT OR HIRE LICENSED ELEVATOR CONTRACTOR TO PULL PERMIT TO DECOMMISSION UNIT. 331 N CENTRAL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST AT 2 AND 3 - PANES BROKEN AND BOARDED. 331 N CENTRAL AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE NORTH EAST - JUNK/GARBAGE 331 N CENTRAL AVE PERIODIC FAILED View
RATS SOUTH BASEMENT - EVIDENCE OF RATS 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION TO VERIFY OCCUPANCY AND DETECTORS OF RESIDENTIAL UNITS. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH- WEST WALL;FRACTURE 331 N CENTRAL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 331 WEST ELEVATION 2ND FLR. AND EAST ELEVATION 1ST TO 3RD FLR.WINDOW PANES;BROKEN 331 N CENTRAL AVE PERIODIC FAILED View
BLOCKED FIRE DOOR 331,335,337 -NON RESIDENT UNITS,REAR EXITS BLOCKED WITH STOCK. 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN WINDOW EAST ELEVATION 1ST AND 2ND FLR.WINDOW FRAMES;ROTTED 331 N CENTRAL AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D SIGN POSTED. 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENTS IN ORDER TO VERIFY DETECTORS. 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NO BUILDING REGISTRATION FROM 1990 THROUGH 2012. 331 N CENTRAL AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D SIGN POSTED. 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT REAR PORCHES, APARTMENTS, INTERIOR STAIRWAYS AND COMPLAINTS OF BED BUGS IN APARTMENT 103 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NO BUILDING REGISTRATION FROM 1990 THROUGH 2013. 331 N CENTRAL AVE PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH WEST ELEVATION - MARBLE STONE GUARDRAIL - OPEN JOINTS AND WASHED OUT MORTAR. 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL EXIT SIGN 337 N. / 1ST FLOOR STORE - FRONT EXIT SIGN - MISSING. 331 N CENTRAL AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY 335 N. / 1ST FLOOR STORE - REAR EXIT DOOR - BLOCKED WITH SHOE BOXES. 337 N. / 1ST FLOOR STORE - REAR EXIT DOOR PERMANENTLY CLOSED - UNVERIFIED LAYOUT AND OCCUPANCY. 331 N CENTRAL AVE PERIODIC FAILED View
FLAKY INTERIOR PAINT 337 N. / 1ST FLOOR STORE - REAR STORAGE ROOM CEILING - FLAKING PAINT. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION - ABOVE WINDOW LINTEL - BRICKS BULGING OUT. 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NO BUILDING REGISTRATION FROM 1990 THROUGH 2014. 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN WINDOW ALL ELEVATIONS - BOARDED WINDOWS AND ROTTED WINDOW FRAMES WITH PEELING PAINT AT VARIUOS LOCATIONS. 331 N CENTRAL AVE PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS EAST ELEVATION - MISSING WINDOW SCREENS. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION WINDOW SILLS - WASHED OUT MORTAR. 331 N CENTRAL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EASTR ELEVATION 2ND FLOOR WINDOW BOARDED UP. 331 N CENTRAL AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NO BUILDING REGISTRATION FROM 1990 THROUGH 2014. 331 N CENTRAL AVE PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH WEST ELEVATION - MARBLE STONE GUARDRAIL - OPEN JOINTS AND WASHED OUT MORTAR. 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL COVERS ABOVE RETAIL SPACE AT FRONT OPEN ELECTRICAL BOXES LIGHTED SIGN REMOVE 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION WINDOW SILLS - WASHED OUT MORTAR. 331 N CENTRAL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EASTR ELEVATION 2ND FLOOR WINDOW BOARDED UP. 331 N CENTRAL AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND #331, 333 1/2 STOREFRONTS - VACANT 331 N CENTRAL AVE PERIODIC FAILED View
NO POSTED ADDRESS #331 STOREFRONT - ADDRESS NOT POSTED 331 N CENTRAL AVE PERIODIC FAILED View
FIRE EXTNGSHR REQ, NONRESDNTL #331 1/2, #337 STOREFRONTS - FIRE EXTINGUISHERS - EXPIRED 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EAVES WEST - #333 1/2 STOREFRONT - FRONT ENTRANCE - LOOSE PLASTER AT CEILING SOFFIT 331 N CENTRAL AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE EAST - TRASH, DEBRIS, GARBAGE, JUNK. MATTRESSES AT REAR 331 N CENTRAL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE EAST - COUCH, MATTRESS STORED IN REAR 331 N CENTRAL AVE PERIODIC FAILED View
DEMO DEBRIS EAST - PILE OF BRICKS AT REAR 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN WINDOW EAST - WINDOW FRAMES, TRIM - ROTTING; PAINT PEELING 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR OR REPLACE WEST - #337 EXTERIOR SIGN - PAINT PEELING; FLAKING (SEC.7-28-060) 331 N CENTRAL AVE PERIODIC FAILED View
ILLUMINATE EXIT AREAS EAST - REAR EXIT - EXTERIOR ILLUMINATION MISSING 331 N CENTRAL AVE PERIODIC FAILED View
NOTIFY DOB, USE OF VACANT LND #331, #335 1/2, AND #337 STOREFRONTS - VACANT 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - WINDOW SCREENS - TORN OR MISSING THRU-OUT 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR EAST - REAR ENTRY DOOR - RUSTING 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST - REAR ENTRY DOOR - DOOR KNOB MISSING 331 N CENTRAL AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE EAST - STOVE STORED IN REAR 331 N CENTRAL AVE PERIODIC FAILED View
NO POSTED ADDRESS #331 1/2 STOREFRONT - ADDRESS NOT POSTED 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR OR REPLACE WEST - #337 EXTERIOR SIGN - PAINT PEELING; FLAKING (SEC.7-28-060) 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR LINTELS WEST - LINTEL - RUSTING ABOVE RESIDENTIAL DOORWAY AT NW ENTRANCE 331 N CENTRAL AVE PERIODIC FAILED View
CUT OR REMOVE HIGH WEEDS EAST - WEEDS THRU-OUT REAR 331 N CENTRAL AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR COMPLAINANT NO LONGER A RESIDENT AT THIS ADDRESS. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND ALL STOREFRONTS. UNVERIFIED DETECTORS AND CONDITIONS. 331 N CENTRAL AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST - 1ST-3RD FLOORS - WINDOWS - BROKEN, BOARDED, AND MISSING PANES 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR FENCE 06-00554674 NORTH EAST CORNER OF PROPERTY - BROKEN FENCING 331 N CENTRAL AVE PERIODIC FAILED View
LICENSED BONDED PLMBG CONTRCTR EMPLOY LICNESED PLUMBER (18-29-106.1 THRU 106.2) 331 N CENTRAL AVE PERIODIC FAILED View
STOP LEAKING WATER STOP LEAKING WATER IN BASEMENT BOILER ROOM (18-29-102.3) 331 N CENTRAL AVE PERIODIC FAILED View
REPLACE DEFECTIVE VALVE,PIPING INSTALL RETURN LINE PUMP (18-29-102.3) 331 N CENTRAL AVE PERIODIC FAILED View
CUT OR REMOVE HIGH WEEDS EAST BUILDING AREA;HIGH WEEDS 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION - MARBLE STONE CORNICE - WASHED OUT MORTAR JOINTS. 331 N CENTRAL AVE PERIODIC FAILED View
DEMO DEBRIS EAST - PILE OF BRICKS AT REAR 331 N CENTRAL AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY #35 STOREFRONT - REAR EXIT OBSTRUCTED BY BOXES, MERCHANDISE. 331 N CENTRAL AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY NORTHEAST STAIRWAY 1-3 FLOORS - GARBAGE CANS OBSTRUCTING EGRESS. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRONT ENTRANCE DOOR -MISSING KNOB 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR WINDOW SILLS ALL ELEVATIONS - OPEN SILL JOINTS. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING GRADE, 1ST,2ND AND 3RD FLOOR CORRIDORS AND STAIRWAYS - DAMAGED WALLS AND CEILINGS AT VARIOUS LOCATIONS . 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL ALL ELEVATIONS - FRACTURES AND ERODED MORTAR AT VARIOUS LOCATIONS'WEST ELEVATION - FRACTURES, LOOSE AND SPALLED STONES AT VARIOUS LOCATIONS. LOOSE ROUNDED STONE COLUMN NEEDS TO BE ABATED ASAP,PERMIT FOR REPAIRS REQUIRED. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRONT ENAND 331 N CENTRAL AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE 1ST,2ND AND 3RD FLOORS - MISSING PEEP HOLES AT VARIOUS LOCATIONS THRU-OUT. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 1ST,2ND AND 3RD FLOOR CORRIDOR AND STAIRWAYS -BEEPING SMOKE ALARM, PROVIDE 10YR BATTERY ALARMS. 331 N CENTRAL AVE PERIODIC FAILED View
CHIMNEY CHIMNEY - FRACTURES AND ERODED MORTAR . 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE REAR ALLEY EXIT DOOR - MISSING DOOR KNOB 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR LINTELS ALL ELEVATIONS GRADE,1ST 2ND AND 3RD FLOORS INCLUDING COURTYARD - RUSTED AND BOWED LINTELS. MOST FACE BRICK ELEVATIONS LINTELS ARE COVERED WITH ALUMINUM PANELS. EXAMINATION REQUIRED , CONDITIONS UNKNOWN . THERE ARE LINTEL VOLUMETRIC EXPANSION MASONRY FRACTURES WITH BULGING BRICKS AT LOAD AND BEARING SECTIONS. PERMIT REQUIRED FOR ANY LINTEL REPLACEMENTS. (SEC 14X-3-303.1.1) 331 N CENTRAL AVE PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED 3TH FLOOR NW STAIRWAY - EXIT SIGN FACING WRONG WAY 331 N CENTRAL AVE PERIODIC FAILED View
PARAPET & COPING FRONT AND COURTYARD FACE BRICK ELEVATIONS INCLUDING FRONT DECORATIVE RAILS - FRACTURES,LOOSE ERODED WITH SHIFTED MASONRY INCLUDING COPINGS. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - BROKEN, MISSING OR TORN SCREENS THRU-OUT. 331 N CENTRAL AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH AND EAST COMMON BRICK ELEVATIONS -FRACTURES AND ERODED MORTAR AT VARIOUS LOCATIONS.WEST FACE BRICK ELEVATIONS INCLUDING COURTYARD - FRACTURES , LOOSE AND ERODED MORTAR/BRICKS.SHIFTED AND LOOSE TERRA COTTA COLUMNS AND CORNICES . CONDITIONS OF TIES UNKNOWN THRU-OUT . PROVIDE CONDITIONS ASSESMENT REPORT OF ALL FACE BRICK ELEVATIONS PER SECTIONS (14X-1-1-4.1, 14X-1-104.2, 14X.1.104.3, 14X-1-104.4, 14A-4-411.1, 14A-4-412.1.1, 14A-6-603.5) PLANS AND PERMITS ARE REQUIRED PER REPORT FOR REPAIRS/REBUILD . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL (SEC 14A-4-401.1) 331 N CENTRAL AVE PERIODIC FAILED View