Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 12:07 PM
PIN: 26062090330000
Property Address: 8832 S COMMERCIAL AVE
City - Zip: CHICAGO - 60617
2023 Property Class: 212
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70100
2023 Tax District: 70039
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 26 Violations
Violation Inspector Comments Address Category Status View
DEFECTIVE POWER SERVICE REPAIR DEFECTIVE POWER SERVICE TO 2ND FLOOR APARTMENT, A PERMIT IS REQUIRED TO CORRECT VIOLATION 8832 S COMMERCIAL AVE COMPLAINT PASSED View
ADDITIONAL EXIT THE PLANS TO BE SUBMITTED ARE TO DETAIL A NEW, CLEARLY MARKED DEDICATED REAR EXIT CORRIDOR/PATHWAY IF THE CONSTRUCTION OF A VIABLE CLEARLY MARKED REAR EXIT PATHWAY DOES NOT OCCUR THIS 1ST FLOOR COMMERCIAL SPACE CANNOT BE OPENED (THIS SPACE CURRENTLY CLOSED BY COMMISSIONER ORDER) 8832 S COMMERCIAL AVE COMPLAINT FAILED View
WORK NOT ALLOWED IF ARCHITECTURAL PLANS ARE NOT SUBMITTED AND A RENO PERMIT IS NOT ISSUED ALL OF THE WORKED PERFORMED IN THE 1ST FLOOR SPACE IS TO BE REMOVED 8832 S COMMERCIAL AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS THERE ARE NO SMOKE DETECTORS IN THIS SPACE DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
BUILDING IN DISREPAIR THIS 1ST FLOOR SPACE A FORMER FUNERAL PARLOR IS BEING OPERATED AS AN UNLICENSED PPA A FULL CALENDAR OF PARTIES BOTH PAST AND FUTURE WAS ON DISPLAY A CROWD IN EXCESS OF 50 PERSONS WAS PRESENT AT THIS "FOR RENT" PARTY VENUE THERE ARE NO SMOKE DETECTORS EXPOSED WIRING WAS OBSERVED THE REAR EGRESS SITUATION IS SO DANGEROUS THAT IT HAS TO BE CONSIDERED AN IMPOSSIBILITY TO SAFELY TRAVERSE THE EXIT CORRIDORS AND SAFELY EXIT THIS BUILDING IN AN EMERGENCY THE DOB AND BACP HAVE BOTH ISSUED CLOSURES DUE TO -IMPROPER LICENSING AND DANGEROUS AND HAZARDOUS CODE VIOLATIONS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID THERE ARE NO CARBON MONOXIDE DETECTORS IN THIS SPACE DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
PROVIDE IN ADDITION TO MISSING/OR DAMAGED EXIT SIGNAGE THE SIGNS ARE NOT PROPERLY PLACED AT THE APPROPRIATE EXIT LOCATIONS ALSO THE 2 REAR EXIT CORRIDORS CAN AND DO LEAD TO DEAD END AREAS WHERE EGRESS IS NEARLY IMPOSSIBLE THERE IS ABSOLUTELY NO DIRECTIONAL SIGNAGE TO MITIGATE THE LADYRINTH THAT IS THE REAR EGRESS CONDITION OF THIS UNLICENSED PPA DANGEROUS AND HAZARDOUS THE FOLLOWING SECTION CODE MUST BE ADHERED TO WHEN PREPARING DRAWINGS TO BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS SECTION 10(13-160-700) THROUGH TO SECTION 10(13-160-770) PLANS AND PERMITS REQUIRED 8832 S COMMERCIAL AVE COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE MIXED USE BUILDING NO ENCLOSURE FOR THE 1ST FLOOR FURNACE PROVIDE AN ENCLOSURE WITH AT LEAST 1 HOUR FIRE RESISTANCE 8832 S COMMERCIAL AVE COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED THE EXIT SIGN AT THE REAR (ALLEY) DOOR IS INOPERABLE 8832 S COMMERCIAL AVE COMPLAINT FAILED View
HEATING PLANT/BOILER ROOM DOOR PROVIDE A CLASS B FIRE DOOR FOR THE 1ST FLOOR FURNACE ENCLOSURE TO BE CONSTRUCTED 8832 S COMMERCIAL AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL THERE ARE NO CERTIFIED/TAGGED FIRE EXTINGUISHERS ON SITE DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
POST APPROVED OCCUPANCY CARD THIS SPACE IS BEING OPERATED AS AN (UNLICENSED) PPA AND HAS NO CERTIFIED OCCUPANCY PLACARD ISSUED BY THIS DEPARTMENT 8832 S COMMERCIAL AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM THE REAR EXIT STAIRWELL (INTERIOR) HAS NO HAND RAILS DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE THE EXIT SIGNS AT 2 REAR EXIT CORRIDORS THAT LEAD TO DEAD ENDS EACH EGRESS ARE NOT CLEARLY MARKED WITH ANY DIRECTIONAL SIGNAGE THE RESULT OF NO SUCH DIRECTIONAL SIGNAGE IS A LABYRINTH OF DEAD ENDS AND UNMARKED EXIT PATHS IT WOULD BE IMPOSSIBLE TO EXIT THIS SPACE AT THE REAR IN THE EVENT OF AN EMERGENCY DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR THIS FORMER FUNERAL HOME HAS BEEN ALTERED INTO A NOW EXISTING, UNLICENSED EVENT SPACE, A GENERAL MERCHANTILE LICENSE EXISTS IT IS NOT SUFFICIENT, THIS 1ST FLOOR SPACE IS BEING OPERATED AS A PPA PARTY VENUE WITH GUESTS IN EXCESS OF 50 ALCOHOL IS BEING SOLD TICKETS TO ATTEND ARE BEING SOLD FOOD IS BEING SERVED/SOLD MUSIC ENTERTAINMENT IS BEING PROVIDED ALSO THE INTERIOR HAS BEEN RECENTLY REHABBED WITH NEW ELECTRICAL WIRING AND FIXTURES AS WELL AS NEW PLUMBING PIPING/FIXTURES ARCHITECTURAL PLANS ARE REQUIRED TO OBTAIN A RENOVATION PERMIT FOR THE WORK PERFORMED PREVIOUSLY AND THE WORK TO BE PERFORMED TO CORRECT THE EXISTING VIOLATIONS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR THERE IS A KEY LOCK ON THE EXIT DOOR AT THE REAR (ALLEY) DANGEROUS AND HAZARDOUS 8832 S COMMERCIAL AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
PARAPET PARAPET WALL MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLR.WINDOW PANE;V BROKEN. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
PARAPET NORTH AND SOUTH ELEVATION PARAPET WALLS; MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AND WEST EXTERIOR WALLS; MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
MAINTAIN WINDOW WEST WINDOW FRAME; ROTTED. 8832 S COMMERCIAL AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLR.WINDOW PANE;V BROKEN. 8832 S COMMERCIAL AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL NORTH AND WEST EXTERIOR WALLS; MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT PASSED View
MAINTAIN WINDOW WEST WINDOW FRAME; ROTTED. 8832 S COMMERCIAL AVE COMPLAINT PASSED View
PARAPET NORTH AND SOUTH ELEVATION PARAPET WALLS; MORTAR MISSING. 8832 S COMMERCIAL AVE COMPLAINT PASSED View