The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEBRIS, EXCESSIVE | JUNK REAR YARD AND REAR BASEMENT STAIRWELL | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SIDE PORCH SOUTH GRADE TO FIRST NO FOUNDATION NO RAILS, TREADS AND DECK 20 INCHES WIDE REAR PORCH LOOSE BEAM 2ND FLR INADEQUATE BRACKET SUPPORT OF BEAM LOOSE STINGER AND SCAB STRINGER G-2 PLANS AND PERMIT NEEDED TO REAPAIR 1ST FLR. | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
INTERIOR FINISH FIRERESISTANCE | WOOD PANELED WALLS FRONT STAIRWAY INAQUATE FIRE SEPERATION | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY 2ND FLR. TO INSPECT COMPLAINCE OR OVER KROWDING NO RESPONSE ALSO ENTRY REFUSED TO OPEN DOOR. | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO POSTING OF OWNERSHIP | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR YARD DEMO DEBRIS | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR NO SMOKE DETECTORS | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH: VERTICAL COLUMNS UNDERSIZE: 2) NO FOOTING: 3) HAND AND GUARD UNDER 42 INCHES AND LOOSE. | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMIT FOR PORCH REPLACEMENT | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
CEMENT BASEMENT FLOOR | BASEMENT NO CONCRETE FLOOR | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE PVC UNDERGROUND IN BASEMENT CRAWL SPACE | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | FLEXIBLE CONNECTIONS AT WATER HEATER 1ST FLOOR FRONT | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | PROVIDE PLANS & PERMITS FOR ENTIRE BUILDING | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | FLEXIBLE CONNECTIONS AT WATER HEATER | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
INSTALL INDIRECT SANT. WASTE | PROVIDE A OPEN SITE WASTE OR FLOOR DRAIN TO CONVEY THE DISCHARGE OF RELIEF VALVE. AT 1ST FLOOR FRONT WATER HEATER AS PER CODE (18-29-504.7) | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
EXPOSE FOR INSPECT APPROVAL | PROVIDE AN INSPECTION OF PIPING BEHIND PLUMBING WALLS | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | SERVICE ON OUTSIDE OF BUILDING REAR | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN JUNCTION BOX 1ST FLOOR FRONT UNIT FRONT ROOM | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSE WIRE | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | PULL CHAIN PORCELAIN FIXTURE BATHROOM | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
PROVIDE | PROVIDE DRIP PANS UNDER WATER HEATER 1ST FLOOR FRONT AS PER CODE (18-29-504.8) | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | PEELING PAINT KITCHEN CEILING 1ST FRONT APT. | 4511 S LAFLIN ST | COMPLAINT | FAILED | View |