Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 6:30 AM
PIN: 16262240090000
Property Address: 2525 S CENTRAL PARK AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 29 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# POST OWNERS I.D. 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
PARAPET & COPING OPEN MORTAR JOINTS WEST PARAPET LOOSE COPING STONES 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
REPAIR BALCONY OPEN MORTAR JOINTS WEST BALCONY 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
CHIMNEY OPEN MORTAR JOINTS SOUTH CHIMNEY 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
REPUTTY WINDOW PANES LOOSE AND MISSING WINDOW PUTTY ATTIC WEST 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
MAINTAIN WINDOW SASH ROTTED WINDOW SASHES ATTIC WEST 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL OPEN MORTAR JOINTS SPALLING BRICKS SOUTH AND WEST 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED ROOTED EAVES AT GARAGE 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
NO POSTED ADDRESS FRONT ADDRESS IS NOT POSTED, AT REAR GARAGE WRONG ADDRESS IS POSTED. 2525 S CENTRAL PARK AVE COMPLAINT PASSED View
PROVIDE A DRIP PAN UNDER WATER HEATER(ATTIC), (18-29-504.8)AS PER CODE 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN 1ST FLOOR-FAMILY UNITS HAVE BEEN CONVERTED TO 2 UNITS 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR 1ST FLOOR-SUBMIT PLANS AND PERMITS FOR DECONVERSION 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
WORK NOT ALLOWED 1ST FLOOR-RESTORE SPACE TO ITS ORIGINAL CONFIGURATION 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE ATTIC-REMOVE ALL JUNK ACCUMULATION 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS STAIRWELL- NO SMOKE DETECTOR 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY REAR PORCH-REMOVE BOXES, OLD REFRIGERATOR 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
INTERIOR FINISH FIRERESISTANCE 1ST & 2ND FLOOR-REMOVE OR TREAT WOOD PANEL 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING WITH DEPARTMENT OF BUILDINGS FOR 1990-2006 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
PROV HOT WTR TO ALL FIXTURES NO HOT WATER AT 1ST FLOOR, REAR NORTH UNIT 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
INSTALL INDIRECT CLEAR WASTE PROVIDE AN OPEN SITE WASTE OR FLOOR DRAIN PROPERLY TRAPPED & VENTED TO CONVEY WATER FROM WATER HEATER 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS PROVIDE A DIAELECTRIC UNION ON ALL DOMESTIC WATER LINES WHEN METALS OF DISSIMILAR MATERIAL COLLIDE AT ATTIC WATER HEATER 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
PROV 1"AIR GAP ABV OVRFLW RIM TUB SPOUT MUST BE AT LEAST 1" ABOVE SPILL LINE OF FIXTURE AT 1ST FLOOR REAR BATHTUB; REMOVE HOSE BIBB AT ATTIC TO PREVENT ANY BACK SYPHONAGE INTO CHICAGO'S WATER SYSTEM 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
SEAL DRAIN OPENING UNUSD FIXTR REMOVE ALL DEAD PIPE AT 1ST FLOOR, FRONT, WATER HEATER LOCATION 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT TO CORRECT ALL PLUMBING VIOLATIONS; (2) ILLEGAL CONVERSIONS 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT REMOVE ALL PLUMBING ILLEGALLY , IMPROPERLY INSTALLED WITHOUT PERMITS; (2) ILLEGAL CONVERSIONS AT 1ST FLOOR REAR UNITS 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC A LICENSED & BONDED PLUMBING CONTRACTORIS REQUIRED 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES PULL CHAIN LIGHT IN ATTIC 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
PRV DISCHARGE PIPE FROM PRV PROPERLY SIZE RELIEF VALVE DISCHARGE PIPES AT 1ST FLOOR REAR & AT ATTIC WATER HEATER 2525 S CENTRAL PARK AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE 2525 S CENTRAL PARK AVE COMPLAINT PASSED View