Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRS 3RD FLOOR NO SMKE DETECTOR. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS FRONT INTERIOR STAIRS SMOKE DETECTOR BEEPING. 2917 W 25TH ST COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT IRON GATE DOUBLE CYLINDER LOCKS. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR COACH HOUSE STAIRS GRADE TO 2ND FLOOR .4X4 COLUMNS ERECTED ON SERVICE WALK LEDGER BOARD NAILED. STRINGER AND HAND RAILS NAILED TO COLUMNS,HEADERS AND WALL .GUARD RAILS 30" HIGH. COACH HOUSE 2ND FLOOR ENCLOSED PORCH JOIST NAILED TO HEADERSPERMIT REQUIRED FOR REPAIRS TO REAR STAIRS AND ENCLOSED PORCH. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT 1ST AND 2ND FLOOR STEP CRACKS.NORTH AND SOUTH ELEVATION - 1ST,2ND 3RD FLOOR LOOSE MORTAR 2917 W 25TH ST COMPLAINT CLOSED View
NO KEY TO USE EXIT DOOR FRONT IRON GATE DOUBLE CYLINDER LOCKS. 2917 W 25TH ST COMPLAINT CLOSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE STEP CRACKS NEXT TO COACH HOUSE. 2917 W 25TH ST COMPLAINT CLOSED View
REPAIR/REPLACE SMOKE DETECTORS FRONT INTERIOR STAIRS SMOKE DETECTOR BEEPING. 2917 W 25TH ST COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY FRONT BASEMENT EXTERIOR DOOR HAS PLASTIC COVERING THE DOOR. 2917 W 25TH ST COMPLAINT CLOSED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRS 3RD FLOOR NO SMKE DETECTOR. 2917 W 25TH ST COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR FRONT STAIRS GRADE TO BASEMENT NO HAND RAIL.REAR HOUSE STAIRS NO HAND RAIL. 2917 W 25TH ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR COACH HOUSE STAIRS GRADE TO 2ND FLOOR .4X4 COLUMNS ERECTED ON SERVICE WALK LEDGER BOARD NAILED. STRINGER AND HAND RAILS NAILED TO COLUMNS,HEADERS AND WALL .GUARD RAILS 30" HIGH. COACH HOUSE 2ND FLOOR ENCLOSED PORCH JOIST NAILED TO HEADERSPERMIT REQUIRED FOR REPAIRS TO REAR STAIRS AND ENCLOSED PORCH. 2917 W 25TH ST COMPLAINT CLOSED View
REPAIR WINDOW SILLS REAR 1ST 2ND AND 3RD FLOOR WINDOW SILLS OPEN MORTAR JOINTSMASON PERMIT REQUIRED FOR ALL MASONARY WORK TO BE DONE. 2917 W 25TH ST COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY FRONT BASEMENT EXTERIOR DOOR HAS PLASTIC COVERING THE DOOR. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT STAIRS GRADE TO BASEMENT NO HAND RAIL.REAR HOUSE STAIRS NO HAND RAIL. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT 1ST AND 2ND FLOOR STEP CRACKS.NORTH AND SOUTH ELEVATION - 1ST,2ND 3RD FLOOR LOOSE MORTAR 2917 W 25TH ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE STEP CRACKS NEXT TO COACH HOUSE. 2917 W 25TH ST COMPLAINT FAILED View
REPAIR WINDOW SILLS REAR 1ST 2ND AND 3RD FLOOR WINDOW SILLS OPEN MORTAR JOINTSMASON PERMIT REQUIRED FOR ALL MASONARY WORK TO BE DONE. 2917 W 25TH ST COMPLAINT FAILED View