Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTORS THROUGHOUT INOPERABLE AND MISSING | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
CARPETING | FRONT STAIRS TORN CARPET | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | PERMIT REQUIRED FOR PERIMETER FENCE | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ENTRY CLAY ROOF TILES BROKEN, REAR PORCH EVIDENCE OF ROOF LEAKS | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | REAR PORCH EGRESS OBSTRUCED WITH ITEMS AND GARBAGE BAGS | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR ALL BASEMENT ALTERATIONS FROM ORIGINAL USE AS STORAGE TO CURRENTLY DWELLING UNIT, OR, FOR THE DECONVERSION OF THE BASEMENT TO ITS ORIGINAL USE AND PLANS | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | BASEMENT CONVERTED FROM STORAGE TO DWELLING UNIT | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | SEPARATION FROM BASEMENT TO 1ST FLOOR NOT 1 HOUR | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
PARTITIONS, N/L/B - BASEMENT | PARTITIONS IN BASEMENT ARE NOT 1 HOUR FIRE RATED | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
WINDOW AREA ABOVE GROUND | BASEMENT HAS INSUFFICIENT NATURAL LIGHT AND VENTILATION | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - JOISTS ARE OVERSPANNED, WATER DAMAGED AND ROTTING, TREADS ARE WORN AND LOOSE WITH INCONSISTENT RISER HEIGHTS, DECK WOOD IS ROTTING, BEAM TO COLLUMN CONNECTIONS IMPROPER, PLANS AND PERMIT REQUIRED FOR REPAIR OR REPLACEMENT OF ENTIRE PORCH STRUCTURE | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | REAR ENCLOSED PORCH - EXPOSED BEADED PINE | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPER MATERL | LAVATORY - TOILET - KITCHEN SINK - REMOVE PVC WATER LINES, REPIPE WITH APPROVED MATERIALS - 2ND FLOOR | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE PLBG FIXTURE | REPAIR TUB ENAMEL FINISH DAMAGED - 2ND FLOOR | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
VENT 5' WITHIN TRAP | VENT WASTE PIPE FOR LAUNDRY TUB - BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WATER PIPING | INSTALL AIR CHAMBERS FOR LAUNDRY TUB - BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
REMV SADDLE HUB CONNECTIONS | REMOVE SADDLE CONNECTION ON UNDERGROUND SOIL LINE BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING FIXTURES IN BASEMENT INSTALLED WITHOUT A PERMIT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
INDIRECT CONN.FOR WATER SUPPLY | INSTALL RPZ ON WATER SUPPLY BOILER - BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | PIPE RELIEF VALVE DISCHARGE PIPE TO 6" ABOVE FINISH FLOOR - WATER HEATER - BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL PERMIT FOR PLUMBING | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
DEFECTIVE LIGHTING SERVICE | REPLACE DEFECTIVE SERVICE RISER | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHTS THROUHGOUT SECOND FLOOR UNIT, AND BASEMENT AREAS - AND OTHER TYPICAL UNITS THROUGH OUT BUILDING | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THROUGH OUT PORCH AREA AND BASEMENT AREAS | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT SERVICE RISER - HANGING WITHOUT SUPPORTS IS DANGEROUS AND HAZARDOUS CONDITION | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
GROUNDING RECEPTACLES | PROVIDE GROUNDING TYPE RECEPTACLES THROUGHOUT 2ND FLOOR AREA AND OTHER TYPICAL UNIT THROUGH OUT BUILDING | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS, AND GARAGE ACCORDING TO ARTICLE 18-27-210.25 | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View | |
REPAIR**************** | REMOVE ALL DETERIOATED WIRING THROUGHOUT PORCH AREA AND BASEMENT AREA ACCORDING TO ARTICLE 18-27-110.7 | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
REMOVE************** | PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGH OUT BASEMENT AREA ACCORDING TO ARTICLE 13-12-380 | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AND WITHOUT PLANS & PERMITS | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALLOW FOR A FULL INTERIOR INSPECTION OF THE ENTIRE PROPERTY INCLUDING ALL ENCLOSED SPACES, BASEMENT, PORCHES. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | MISSING CHIMNEY CAP LOCATED AT THE NORTHEAST LOCATION. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER/MANAGEMENT SIGN REQUIRED FIXED TO PROPERTY WITH NAME, NUMBER, ADDRESS/CONTACT INFO IN CASE OF EMERGENCY. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT OF PROPERTY WEST ELEVATION GATE MISSING HARDWARE NO KNOB AT TIME OF INSPECTION. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | ON THE NORTH ELEVATION OF THE BUILDING THE GROUNDING CONDUIT COMING FROM THE METER BANK IS DISCONNECTED. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |
PRV FLUE FOR HOT WATER HEATER | REPIPE FLUE PIPE TO WATER HEATER - BASEMENT | 109 S PARKSIDE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | FRONT OF PROPERTY IRON PICKET FENCE OVER 5'. REDUCE HEIGHT, REMOVE, OR OBTAIN PERMIT TO STAND AS IS. | 109 S PARKSIDE AVE | COMPLAINT | FAILED | View |