The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 1 STORY FRONT PORCH, GUARDRAILS LESS THAN 42" HANDRAILS LESS THAN 36" & LOOSE STAIRS LEANING STRINGERS CRACKED & SPLITING, PICKETS SPACED MOREVTHAN 4 1/2 " APART FOOTING CRACKED & BROKEN, UPRIGHTS ROTTED DECKING ROTTED & LOOSE | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1 STORY REAR PICKETS SPACED MORE THAN 4 1/2" HANDRAILS LESS THAN 36" TREADS UNDERSIZED SHOULD BE 2"X12"'S STRINGER OVERCUT NO FOOTING FOR UPRIGHTS, ANCHOR BOLTS MISSING ON LEDGER BOARDS | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ONTAIN PERMITS BEFORE PERFORMING WORK, NO PLANS REQUIRED | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View | |
REPAIR ROOF | SOUTH & WEST ELEVATIONS | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | DRAFTY WINDOWS THROUGHOUT | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION- RAILING SYSTEM MISSING PICKETS | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | REAR- ILLUMINATION MISSING. | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE , UNVERIFIED DETECTORS AND OCCUPANCY.UNABLE TO VERIFY COMPLAINT OF MOLD ON BASEMENT WALLS, AND , ONE EXIT OUT OF BASEMENT. | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 1ST AND 2ND FLOOR / NO RESPONSE, UNVERIFIED DETECTORS AND OCCUPANCY . | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 6915 S WINCHESTER AVE | COMPLAINT | FAILED | View |