The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION FROM PORCH TO ALLEY - MISSING SERVICEWALK. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
RAT PROOF EXTERIOR DOOR | NORTH ELEVATION - BASEMENT DOOR - 11/2 GAP AT BOTTOM. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | SOUTH ELEVATION - ABANDONED VEHICLES IN BACKYARD. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | APT. #2-MISSING CARBON MONOXIDE DETECTOR. | 3165 W MONROE ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR APARTMENT /LIVING ROOM 59F,KITCHEN 54F,BEDROOM 2 -60F AT 2:34PM . (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2) | 3165 W MONROE ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2ND FLR APT-INDIVIDUAL FORCED AIR FURNACE HAS BEEN REMOVED.AND MISSING AT TIME OF INSPECTION.PERMIT REQUIRED TO INSTALL NEW FURNACE. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL BY VENTILATION BUREAUS (14X-3-305.1, 14X-8-804.1 THRU 14X-8804.4 AND 14X-8-804.5) | 3165 W MONROE ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2ND FLOOR APT. -HOT WATER FURNISHED AT ONLY 90F( IN KITCHEN)E (14X-9-905.2, 14X-9-905.2.1 AND 14X-9-905.5) | 3165 W MONROE ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | 2ND FLOOR APARTMENT / COLD WATER SHUT OFF (14X-9-905.4) | 3165 W MONROE ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | SOUTH ELEVATION - THREE STORY OPEN WOOD PORCH. 6X6 COLUMNS ARE OVERNOTCHED,PULLING AWAY AT BEAM TO COLUMN FIRE CUTS AND HAVE LARGE SPLITS/CRACKS. RAILINGS ARE 36" HIGH,LOOSE AND TOENAILED TO COLUMNS. STRINGERS ARE FASTENED TO RIM JOISTS WITH COMMON NAILS ONLY. TREADS AND DECK BOARDS ARE BUCKLED AND WORN. PLANS AND PERMIT ARE REQUIRED FOR PORCH REPLACEMENT. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF BED BUGS AND RAT INFESTATION. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 3165 W MONROE ST | COMPLAINT | PASSED | View |
CONNECT DOWNSPOUT TO SEWER | SOUTH ELEVATION - DOWNSPOUT - DRAINING INTO ALLEY. | 3165 W MONROE ST | COMPLAINT | PASSED | View |