Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO HOUSE TO VERIFY COMPLAINTS ON SR#167845347. | 1250 S KOMENSKY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION 1 STORY WOOD PORCH HAS 2X8 JOIST SPANNING (10FT).RAILINGS ARE UNSTABLE AND TOENAILED TO COLUMNS.4X4'S ERECTED ON BLOCKS.DECK IS SAGGING IN CENTER.PERMIT REQUIRED FOR REPAIRS. | 1250 S KOMENSKY AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | NO COLD WATER GROUND. TENANT HEARS ARCINGAT COLD WATER SERVICE. | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
ADD BRANCH CIRCUITS | AT KITCHEN. TENANT RUNNING EXTENSION CORDS SO CIRCUIT DOESN'T BLOW. | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | OUTLETS WITH REVERSE POLARITY, NO GROUND, OR INOPERABLE THROUGHOUT. | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | REPLACE COVERS 2ND FLOOR FRONT BEDROOM. | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
EXPOSED WIRING | REMOVE EXPOSED WIRING AT BASEMENT | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
CORD WIRED EQUIPMENT | USE PROPER WIRING METHODS FOR KITCHEN. | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
CLOSE BOX OPENINGS | CLOSE OPENINGS AT BASEMENT BOXES AND PANELS | 1250 S KOMENSKY AVE | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | SOUTH ELEVATION CHIMNEY FLU PIPE CAP MISSING. | 1250 S KOMENSKY AVE | COMPLAINT | FAILED | View |