The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST, FRONT PORCH: ROOF INADEQUATELY SUPPORTED AT COLUMNS, IMPROPER CONNECTIONS, COLUMNS ARE TWISTED, BEAMS ARE SCABBED AND ROTTING, FRONT STEP IS CRACKED; SUBMIT PLANS AND PERMITS FOR REPAIRS OR REPLACEMENT | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | EAST: FASCIA AND FRIEZE BOARDS ARE ROTTING, REPLACE | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST, WEST; GATES ARE PADLOCKED, ITEMS ON REAR PORCH, 1ST AND 2ND FLOOR | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | WEST, 2ND FLOOR APARTMENT, REAR DOOR: DEAD BOLT LOCKS ARE MISSING LOCKS THAT ARE INSTALLED ARE LOOSE AND INEFFECTIVE | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST: STRINGER IS PULLING AWAY FROM LANDING, LEANING; HANDRAILS ARE LEANING; EXCESSIVE SPACING BETWEEN TOP OF TREAD AND BOTTOM RAIL, UNABLE TO INSPECT THOROUGHLY BEACUSE OF PADLOCK ON GATES; PERMIT NEEDED | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | WEST: DISCARDED ITEMS STORED UNDER STAIRWELL | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND FLOOR, KITCHEN: LOOSE FLOOR TILES | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | (SEC. 7-28-060) 2ND FLOOR, BOTTOM OF KITCHEN SINK: BASE CABINET HAS ROTTED | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ROACHES | 2ND FLOOR APARTMENT: EVIDENCE (DEAD ROACHES) IN KITCHEN AND HALLWAY | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 1ST FLOOR: CEILING IN KITCHEN IS STILL SAGGING AFTER REPAIR JOB | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT REAR PORCHES ON BOTH LEVELS BECAUSE OF THE ITEMS STORED ON PORCHES. NO ACCESS TO REAR YARD-PADLOCKED ON BOTH GATES. NO RESPONSE-BASEMENT UNVERIFIED DETECTORS AND OCCUPANCY | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING DWELLING UNITS NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND COMPLAINT OF FLOODED BASEMENT ALSO REAR PORCH. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,MISSING SMOKE DETECTOR. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FURNACE IS NOT WORKING AT TIME OF INSPECTION. THERMOSTAT IS LOCATED ON 2ND FLOOR WITH IS VACANT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST FLOOR USING OVEN FOR HEAT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR IS 58 DEGREES THROUGHOUT UNIT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING DETECTOR AT 1ST AND BASEMENT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR DETECTOR IS BEEPING, REPLACE BATTERY. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING DETECTOR AT BASEMENT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | WEEDS IN REAR | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR - WINDOW - CRACKED PANE | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURE (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 1628 S RIDGEWAY AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1628 S RIDGEWAY AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | FRONT SECOND FLOOR ENTRANCE DOOR-BROKEN PANE. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APARTMENT #1- MISSING CARBON MONOXIDE DETECTOR. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-APT. #2- NO RESPONSE,UNVERIFIED DETECTORS. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | FRONT ELEVATION-FIRST AND SECOND FLOORS TORN / MISSING SCREENS. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED TWO STORY PORCH-MISSING SMOKE DETECTOR. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CHIMNEY | TWO CHIMNEYS- SPALLED BRICKS,WASHED OUT MORTAR. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | TWO CHIMNEY CAPPINGS- BROKEN CAPPINGS,WASHED OUT MORTAR. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION - BASEMENT STAIRS - MISSING HANDRAIL. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF RATS,CEILING CAVING IN AND WINDOWS FALLING OUT ON 2ND FLOOR. UNVERIFIED OCCUPANCY AND DETECTORS. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 2ND FLOOR APARTMENT - FRONT BEDROOM - MICE DROPPINGS. | 1628 S RIDGEWAY AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR FRONT HALLWAY - SMOKE DETECTOR - MISSING. | 1628 S RIDGEWAY AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND FLOOR APARTMENT - FRONT ROOM SMOKE DETECTOR - BEEPING. | 1628 S RIDGEWAY AVE | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE PARTITIONS AND EXTERIOR DOORS INSTALLED ON ENCLOSED BACK PORCH WITHOUT A PERMIT. | 1628 S RIDGEWAY AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION - 1 STORY OPEN WOOD PORCH.2X6 JOISTS SPANNING 12FT AND DECK IS SAGGING TO THE SOUTH.RAILINGS ARE 36" HIGH.STRINGERS ARE NAILED TO RIM JOISTS WITH COMMON NAILS ONLY.PERMIT REQUIRED FOR PORCH REPAIRS. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF MISSING DETECTORS,NOT HEATED PROPERLY AND DRYWALL HAS LEAD BASE PAINT. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION - WROUGHT IRON GATE - UNABLE TO OPEN/STUCK ON METAL STRIKE PLATE. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST ELEVATION - GUARDRAILS - 2FT HIGH. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION - BASEMENT STAIRS - MISSING HANDRAILS. | 1628 S RIDGEWAY AVE | COMPLAINT | FAILED | View |