The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALL - WASHED OUT MORTAR. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL -BRICKS BULGING ABOVE 2ND FLOOR WINDOW. PERMIT REQUIRED TO REPAIR EXTERIOR WALL. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR AREAWAY WALL | AREAWAY WALL - SPALLING, CRACKED MORTAR. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS - CONCRETE STAIRS SPALLING, CRUMBLING. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS - WASHED OUT MORTAR, GAPS BETWEEN CONCRETE TREADS AND RISERS; OPEN JOINTS AT WING WALLS. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | HANDRAIL MISSING FROM GRADE TO BASEMENT. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN. 2X8 JOISTS SPAN 11'-2"; BEAMS TOENAILED TO COLUMNS; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; RAIL HEIGHT ISONLY 35"; HANDRAIL MISSING FROM GRADE TO BASEMENT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT ENTRY DOOR - PEELING PAINT ON JAMB. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
CONNECT DOWNSPOUT TO SEWER | DOWNSPOUT - NOT CONNECTED TO SEWER SYSTEM. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - SIDING ROTTING AT BASE, PAINT PEELING; GUTTER AND DOWNSPOUTS MISSING; HOLE ON SOFFIT (EAST SIDE) - ROTTING. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOWS - BOARDED. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | TRASH, DEBRIS AT BASEMENT AREAWAY. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE. UNABLE TO INSPECT INTERIOR. UNVERIFIED DETECTORS AND OCCUPANCY. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REMOVE | REAR PORCH - DANGEROUS AND HAZARDOUS. ELECTRICAL CABLES ARE TANGIBLE FROM 2ND FLOOR. SERVICE POLE IS STRAPPED TO 6X6 COLUMN AT SOUTHEAST CORNER WITH ROPE. (SEC. 7-28-060) | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN NOT POSTED. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT ENTRY DOOR - PEELING PAINT ON JAMB. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | TRASH, DEBRIS AT BASEMENT AREAWAY. | 3517 W VAN BUREN ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | SOUTH EXTERIOR STAIRS GRADE TO BASEMENT - MISSING EAST GUARDRAIL. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS ERECTED ON TOP OF CONCRETE BLOCKS; FOUNDATION STATUS UNKNOWN.UNDERSIZED 6"X6" BEAMS SPAN 7'-2", AND ARE FASTENED TO COLUMNS WITH LIGHT GAGE METAL STRAP ONLY.UNDERSIZED 2"X8" JOISTS SPAN 10'-10".STRINGERS ARE FASTENED TO 4"X4" RAILNG POSTS AND COLUMNS WITH NAILS ONLY.TREADS ARE CRACKED AND ONLY 9-1/4" WIDE.GUARD RAILING SECTIONS ARE ONLY 36" HIGH; SECTIONS OVER 4'-0" LONG ARE LOOSE AND PULLING.GUARD AND STAIR RAILING SECTIONS ARE ONLY TOE NAILED TO COLUMNS AND 4"X4" RAILING POSTS.PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - LEANING; SECTIONS MISSING SIDING. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT YARD AND UNDER REAR PORCH - JUNK AND REFUSE ACCUMULATION. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT INTERIOR STAIRWAY AND 2ND FLOOR APT. - NO RESPONSE, UNVERIFIED DETECTORS. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THERE IS A FENCE GATE THAT IS CHANGE AND PADLOCKED PREVENTING EGRESS TO THE PUBLIC WAY. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NO PERMIT ON FILE FOR SIDE LOT FENCE IN EXCESS OF 5'. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST AND EAST BRICK WALLS ... THIS WALL AHS BEEN COMPLETELY SKIM COATED WITH MORTAR (PARGE COATED) WITHOUT ANY MESH SUBSTRATE TO BOND WITH THE MORTAR. THERE ARE NUMEROUS AREAS WHERE THE PARGE COAT HAS FALLEN AWAY WITH LOOSE PARGE COAT IN OTHER AREAS ... DANGEROUS AND HAZARDOUS. PERMIT REQUIRED FOR REPAIRS. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | THE EAST GANGWAY ... THERE IS A LARGE BAY WALL / WINDOW PORTION OF THIS WALL THAT IS SUPPORTED BY A BRICK COLUMN. THIS COLUMN IS IN A SEVERE STATE OF DISREPAIR. THE BRICKS ARE SEVERELY SPALLED AND WATER / WEATHER ERODED. UNSAFE CONDITION ... PERMIT REQUIRED FOR REPAIRS. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | THE REAR SERVISE WAL;K HAS CRACKED / BUCKLED CONCRETE. | 3517 W VAN BUREN ST | COMPLAINT | FAILED | View |