POST OWNER/MANAGERS NAME/# | OWNER/MANAGEMENT SIGN NOT POSTED | 2837 W 25TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ACCUMULATION OF JUNK, TRASH, DEBRIS-ALL COMMON AREAS OF THE PREMISES, INCLUDING THE BASEMENT AND REAR ENCLOSED PORCH SYSTEM AND ATTIC-REFRIGERATOR WITH DOORS ATTACHED IN BACKYARD | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION STAIR SYSTEM: 6X6 COLUMNS RESTED ON CONCRETE BLOCK, FOUNDATION STATUS UNKNOWN, 2X6 LEDGER BEAMS NAILED TO THE BUILDING, SINGLE 2X10 BEAMS, 2X6 JOISTS-10 FEET SPAN, STRINGERS NAILED TO BEAMS, GUARD RAILS 37 INCHES, HAND RAILS 30 INCHES, 13 INCH RISE BETWEEN DECKING AND APT. 2 DOORWAY, MISSING ANGLE IRON, STRONG TIES, JOIST HANGERS, TREAD HANGERS, COLUMN ANCHORS, BOLTS AND LAG SCREWS; SOUTH ELEVATION, ENCLOSED PORCH: LOOSE TREADS, DECKING AT LANDING IS WARPED AND LOOSE, GUARD RAILS 32 INCHES , GUARD RAIL AT ATTIC-23 INCHES, NO BALUSTERS; NORTH AND SOUTH ELEVATION, EXTERIOR CONCRETE STAIRS: FRACTURED AND SPALLING; PLANS AND PERMITS NEEDED FOR ALL WORK ON STAIRS | 2837 W 25TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS AND PERMITS FOR REPAIR OR REPLACEMENT OF STAIR SYSTEMS AND PORCH ENCLOSURE | 2837 W 25TH ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS, WINDOWS: PEELING PAINT | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EAST ELEVATION: BROKEN DOOR FRAME | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION: MISSING SILL-1ST FLOOR | 2837 W 25TH ST | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | REAR, ENCLOSED PORCH: NO (1) HOUR FIRE RESISTANCE | 2837 W 25TH ST | COMPLAINT | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | REAR, ENCLOSED PORCH, UNDERSIDE OF STAIRS: NO (1) HOUR FIRE RESISTANCE | 2837 W 25TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APTS. 1 & 2, AND ENCLOSED PORCH: NO SMOKE DETECTORS | 2837 W 25TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APTS. 1 & 2, AND BASEMENT: NO CARBON MONOXIDE DETECTORS | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | APT. 2: LOOSE FLOOR TILES, KITCHEN | 2837 W 25TH ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REAR ENCLOSED PORCH AT APT. 2: FACE PLATE MISSING | 2837 W 25TH ST | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | APT. 2, SPACE HEATER: TAPED FLUE PIPE | 2837 W 25TH ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTH AND SOUTH ELEVATION, EXTERIOR CONCRETE STAIRS: NO GUARD RAILS | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH ELEVATION , DOOR OFF HINGES , METAL VENEER IS PEELING -SHARP EDGES. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION -ATTIC AND WEST ELEVATION -2ND FLOOR ,BROKEN PANE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS, WINDOWS PEELING OR NO PAINT. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS ,WINDOW FRAMES -LARGE GAPS , INSUFFIECIENT SIZE , LOOSE ALUNINUM TRIM- SHARP EDGES. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION , ROTTEN SILLS AT 2ND FLOOR. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY -SPALLING MORTAR ,LOOSE AND SHIFTING BRICKS , NO CAP. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT -ACCUMULATION OF JUNK. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | BASEMENT -FRACTURED FOUNDATION WALLS ,SPALLING ,CONCRETE, LARGE HOLES. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | PLOANS AND PERMITS FOR STRUCTURAL MEMBERS. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | ENCLOSED PORCH -OPEN SOCKET. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | APT.2 , NO PEEP HOVE.. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | ENCLOSED PORCH ,UNDERSIDE OF STAIRS -NO (1) HOUR FIRE RESTANCE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | APT#2 FLOOR IS NOT LEVEL ,WEAK SPOTS. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APT#2 AND ENCLOSED PORCH , NO SMOKE DETECTOR. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APT@ ,NO CARBON MONOXIDE DETECTOR.. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | APT#1 AND APT#2 , ONLY ONE MEANS OF EGRESS (FRONT). | 2837 W 25TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS, ADDITIONAL MEANS OF EGRESS AND PORCH ENCLOSE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSED PORCH -LOOSE TREADS ,DECKING AT LANDING IS WARPED AND LOOSE,LOOSE ,NO GUARD RAILS AT 1ST FLOOR ,32INCH GUARDRAIL AT 2 ND FLOOR -LOOSE,NO BALUSTERS , PERMIT NEEDED FOR REPAIRS. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING/NORTH ELEVATION,ATTIC WINDOW-BROKEN PANE. REAR BUILDING/SOUTH ELEVATION,ATTIC WINDOW-BROKEN PANE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | FRONT BUILDING/THRU-OUT,WINDOW FRAMES,ROTTED WITH PEELING PAINT. REAR BUILDING/THRU-OUT,WINDOW FRAMES ROTTED WITH PEELING PAINT. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
CHIMNEY | FRONT BUILDING/CHIMNEY-WASHED OUT MORTAR. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT BUILDING/SOUTH ELEVATION-ROTTED EAVES. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT BUILDING/NORTH ELEVATION,ATTIC WINDOW-BROKEN PANE. REAR BUILDING/SOUTH ELEVATION,ATTIC WINDOW-BROKEN PANE. | 2837 W 25TH ST | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | FRONT BUILDING/THRU-OUT,WINDOW FRAMES,ROTTED WITH PEELING PAINT. REAR BUILDING/THRU-OUT,WINDOW FRAMES ROTTED WITH PEELING PAINT. | 2837 W 25TH ST | COMPLAINT | CLOSED | View |
CHIMNEY | FRONT BUILDING/CHIMNEY-WASHED OUT MORTAR. | 2837 W 25TH ST | COMPLAINT | CLOSED | View |
REPAIR EAVES | FRONT BUILDING/SOUTH ELEVATION-ROTTED EAVES. | 2837 W 25TH ST | COMPLAINT | CLOSED | View |
EXPOSED WIRING | BASEMENT -RECEPTICAL WIRES EXPOSED. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | SOUTH ELEVATION: BROKEN SASH-1ST FLOOR | 2837 W 25TH ST | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | ENCLOSED PORCH , NO (1 HOUR) FIRE RESISTANCE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
RATS | BASEMENT ,RAT DROPPINGS . | 2837 W 25TH ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | ALL ELEVATIONS , NO GUTTERS. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | APT. 2: CEILING LIGHT-LOOSE AND EXPOSED WIRES | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | BASEMENT -BROKEN DOOR. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION: BROKEN PANES-WINDOWS; APT. 2: BROKEN PANE-REAR DOOR | 2837 W 25TH ST | COMPLAINT | FAILED | View |
RATS | BASEMENT: RAT DROPPINGS | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH GRADE TO 2ND FLOOR 6X6 AND 4X4 COLUMNS ERECTED ON SERVICE WALK.LEDGER BOARD NAILED TO WALL.1ST FLOOR JOIST NAILED TO HEADER AND 2ND FLOOR JOIST HANGERS RUSTED.GUARD RAILS AND STRINGERS NAILED TO COLUMNS ,HEADERS AND WALL.GUARD RAIL SECTION 6' LONG.PLANS AND PERMIT REQURIED FOR FRONT PORCH .. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT STAIRS GRADE TO BASEMENT NO GUARD RAIL. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR COACH HOUSE NEWER IRON STAIR GRADE TO 2ND FL . PLANS OR PERMIT FOR STAIRS TO FRONT OF COACH HOUSE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | REAR HOUSE ELECT CORD GOING TO REAR COACH HOUSE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | FRONT INTERIOR STAIRS 2ND FLOOR APT NO VIEWING DEVICE .COACH HOUSE FRONT INTERIOR DOOR NO VIEWING DEVICE. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD TIRES AND PILE OF PLYWOOD. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH ELEVATION - 1ST FLOOR EXTERIOR DOOR ROTTED AT BOTTOM OF DOOR. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS TORN AND MISSING THROUGHOUT. | 2837 W 25TH ST | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REAR YARD ABANDONED REFRIGERATOR | 2837 W 25TH ST | COMPLAINT | FAILED | View |