The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR TWO STORY PORCH - PLANS AND PERMITS REQUIRED.FOOTINGS UNKNOWN.COLUMNS 6X6 RESTING ON SERVICE WALK, OVERNOTCHED, AND TWISTED. SOUTH EAST COLUMN SAGGING EXCESSIVELY CAUSING THE LANDINGS TO SLOPE OUT OF LEVEL.LOOKOUT AND BEAM CONNECTION NAILED.JOIST OVER SPAN 2X8X12 FEET, AND FACE NAILED.LEDGER FACE NAILED.DECKING WORN AND BUCKLED VARIOUS LOCATIONS. TREADS WORN.STRINGERS NAIL TO SUPPORTS.GUARDRAILS 30 INCHES IN HEIGHT, OVER SPAN AND NAIL TO COLUMNS. LOOKOUT AT 1ST. LEVEL SECTION CUT OFF AND SCABED WITH SUBSTANDARD FRAMING. | 4735 N MONTICELLO AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS INFO POSTED. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INSPECTION REQUIRED TO VERIFY DETECTORS AND OCCUPANCY. SEC. 13-12-100. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN GLASS BLOCK FRONT BASEMENT WINDOW. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
PARAPET | LOOSE MORTAR, AND OPEN JOINTS. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR STAIR BROKEN PLASTER. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | 1ST FLOOR APARTMENT NO PEEP HOLE. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | BROKEN SERVICE WALK. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | CAR TIRES AND EXCESSIVE STORAGE. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR TWO STORY PORCH - PLANS AND PERMITS REQUIRED.FOOTINGS UNKNOWN.COLUMNS 6X6 RESTING ON SERVICE WALK, OVERNOTCHED, AND TWISTED. SOUTH EAST COLUMN SAGGING EXCESSIVELY CAUSING THE LANDINGS TO SLOPE OUT OF LEVEL.LOOKOUT AND BEAM CONNECTION NAILED.JOIST OVER SPAN 2X8X12 FEET, AND FACE NAILED.LEDGER FACE NAILED.DECKING WORN AND BUCKLED VARIOUS LOCATIONS. TREADS WORN.STRINGERS NAIL TO SUPPORTS.GUARDRAILS 30 INCHES IN HEIGHT, OVER SPAN AND NAIL TO COLUMNS. LOOKOUT AT 1ST. LEVEL SECTION CUT OFF AND SCABED WITH SUBSTANDARD FRAMING. | 4735 N MONTICELLO AVE | COMPLAINT | PASSED | View |