Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR DOOR FRAME FRONT BUILDING WEST AT 2ND - EXTERIOR DOOR FRAME -BRICKMOLD - MISSING. 8257 S BRANDON AVE COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE FRONT BUILDING - 2ND FLOOR WEST DOOR LOCKS - BROKEN. 8257 S BRANDON AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM FRONT BUILDING - WEST PORCH -COLUMNS ERECTED ON CONCRETE BASES - FOUNDATIONS UNKNOWN. UNDERSIZED 2 X 8 DECK JOISTS SPAN 11' 6'' WITH SINGLE 2 X 8 BEAM SUPPORTING SPAN. DECK JOISTS SPACED 22'' ON CENTERS. BEAMS ONLY NAILED TO COLUMNS . STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. ROTTED DECKING. RISERS AND TREADS SPLIT AND ROTTED. HANDRAIL 1ST TO 2ND - SPLIT AND BROKEN TOP RAIL - VERY LOOSE - HAZARDOUS.GUARDRAILS ONLY 36'' HIGH. PLANS AND PERMIT FOR FRONT BUILDING WEST PORCH REPAIRS. 8257 S BRANDON AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS REAR BUILDING - WEST STAIRWAY AT 2ND - SMOKE DETECTOR - MISSING. 8257 S BRANDON AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID REAR BUILDING - 2ND FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING 8257 S BRANDON AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR REAR BUILDING - EAST STAIRWAY - GRADE TO 2ND - ROTTED COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. DECK AT 2ND LEANING SEVERELY. GUARDRAIL AT 2ND - LOOSE AND ONLY 37'' HIGH. PERMIT REQUIRED FOR REAR STAIRWAY REPAIRS. 8257 S BRANDON AVE COMPLAINT PASSED View
INSECTS REAR BUILDING THROUGHOUT - BED BUG INFESTSATION THROUGHOUT . PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT , BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. 2ND FLOOR - FLY INFESTATION. 8257 S BRANDON AVE COMPLAINT PASSED View
USE SANITARY REFUSE CONTAINERS REAR BUILDING AT EAST - GRADE - GARBAGE OVERFLOWING ONTO GROUND - UNSANITARY CONDITIONS. 8257 S BRANDON AVE COMPLAINT PASSED View
REPAIR GUTTER REAR BUILDING - SOUTH GUTTER TIPPED WITH HOLES. 8257 S BRANDON AVE COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED REAR SHED - EAVES - ROTTED . SIDING - ROTTED. 8257 S BRANDON AVE COMPLAINT PASSED View
INSTALL COVERS NEAR FRONT DOOR 2ND FLOOR, AND EXIT 1ST FLOOR 8257 S BRANDON AVE COMPLAINT FAILED View
SUPPORT FIXTURES NEAR FRONT DOOR 2ND FLOOR PAYERS 8257 S BRANDON AVE COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION OPEN PANELS, D&H 8257 S BRANDON AVE COMPLAINT FAILED View
REMOVE AND REPLACE***** DETERIORATED CLOTH WIRING, D&H 8257 S BRANDON AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS REMOVE UNAPPROVED WIRING, USING YELLOW AS NEUTRAL 8257 S BRANDON AVE COMPLAINT FAILED View
PROPER SIZE OCP #14 ON 20 AMP BREAKER D&H 8257 S BRANDON AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG REAR BUILDING - 2ND FLOOR APARTMENT - HOT WATER ONLY 63F. INSUFFICIENT HOT WATER TEMPERATURE. 8257 S BRANDON AVE COMPLAINT PASSED View
COVER OUTLETS AND JBS REAR BUILDING - 2ND FLOOR APARTMENT - UTILITY ROOM WITH HOT WATER HEATER - WALL - OPEN ELECTRICAL JUNCTION BOX. 8257 S BRANDON AVE COMPLAINT PASSED View
EXPOSED WIRING 1ST BEDROOM 8257 S BRANDON AVE COMPLAINT FAILED View