The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | (FRONT BUILDING) SOUTH AND NORTH ELEVATION MASONRY WALLS HAVE SPALLING BRICKS AND DEEP WASHED OUT MORTAR JOINTS. | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | (FRONT BUILDING) NO OWNER I.D SIGN POSTED. | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT AND BACK GATES DOUBLE KEY LOCKS. | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | (REAR BUILDING) 2ND FLOOR APT VERY DIRTY AND UNSANITARY CONDITIONS. | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | (REAR BUILDING)2ND FLOOR APT KITCHEN FLOOR TILES MISSING. | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
BOND AROUND FITTINGS | MISSING COLD WATER GROUND TO THE PANELS OF THE COACH HOUSE. (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | SECURE ALL RACYWAYS THAT ARE HANGING WITHOUT THE PROPER SUPPORT INSIDE AND OUTSIDE BUILDING (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | NEEDS TO INSTALL ADDITIONAL RECEPTACLES THROUGHOUT COACH HOUSE TO EASE THE USE OF EXTENSION CORDS (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | REAR HOUSE 2ND FLOOR NO LIGHTS | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | ARMORED CABLE IN BOXES THROUGHOUT FIRST FLOOR OF THE COACH HOUSE ARE MISSING CONNECTORS.(DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | WIRING DEVICES THROUGHOUT HOUSE HAS PAINTERS TAPE ON THEM. 14E-1-110 (3)B (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | EXCESSIVE USE OF EXTENSION CORDS THROUGHTOUT THE ENTRIE COACH HOUSE. (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
BOX FOR BX | LIGHT FIXTURE ARE MISSING BOXES THROUGHOUT THE ENTIRE COACH HOUSE OPEN SPLICES BEHIND WALLS IN THE ATTIC (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | CLOSE ALL OPENINGS IN BOXES THROUGHOUT THE ENTIRE COACH HOUSE (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
SMOKE & CARBON DETECTORS | MISSING SMOKE DETECTORS THOUGHOUT THE ENTRIE HOUSE(DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | DISCONNECTS FOR SERVICE IS LOCATED IN COACH HOUSE GROUND FLOOR APARTMENT (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
BOX FOR BX | LIGHT FIXTURES ARE MISSING BOXES THROUGHOUT THE ENTRIE COACH HOUSE (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | ARMORED CABLE THROUGHOUT COACH HOUSE IS RUSTED AND DETERIORATED (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOESD WIRING THROUGHOUT THE ENTIRE COACH HOUSE (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | MISSING CONDUIT,WIRES ARE FREE AIR IN THE ATTIC CEILING OF THE COACH HOUSE (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | RECEPTACLES AND SWITCHES ARE MISSING COVER THROUGHOUT COACH HOUSE (DANGEROUS AND HAZARDOUS) | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 2051) 13-32-010 PERMIT REQUIRED WORK CANNOT PROCEED WITHOUT OBTAINING A PERMIT NEED MECHANICAL PLAN AND PERMIT FOR ALL NEW EQUIPMENT | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | 18-28-603.3 METALLIC DUCTS #2- DUCTS SHALL BE CONSTRUCTED AS SPECIFIED IN THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS-ALL NEW DUCT SYSTEMS NEED TO BE SIZED ACCORDING TO THE OF THE NEW FURNACES | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7011) 18-28-711 CARBON MONOXIDE DETECTORS NEED TO PROVIDE UPDATE SMOKE/CARBON MONOXIDE DETECTORS FOR BOTH UNITS | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED ARRANGE FOR COMPLETE PERMIT INSPECTION AND OBTAIN PERMITS FOR WARM AIR HEATING SYSTEMS WHEN WORK IS COMPLETE | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | (VT 7025) 18-13-503.3.1 18-13-503.2 HEATING AND COOLING CRITERIA HEATING AND COOLING SYSTEM DESIGN LOADS FOR THE PURPOSE OF SIZING SYSTEM DESIGN LOADS FOR THE PURPOSE OF SIZING SYSTEMS AND EQUIPMENT SHALL BE DETERMINED IN ACCORDANCE WITH THE PROCEDURE, DESCRIBED IN THE ASHRAE HANDBOOK OF FUNDAMENTALS ALL HEATING EQUIPMENT MUST BE SIZED PROPERLY IN ORDER TO PROVIDE ADEQUATE HEAT TO ALL UNITS-CURRENT SPACE HEATERS ARE NOT INSTALLED TO CODE AND PROVIDE INADEQUQTE HEAT TO ALL UNITS | 2828 S SAWYER AVE | COMPLAINT | FAILED | View |