The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY | CHIMNEY HAS WASHED OUT MORTAR AND OPEN JOINTS. | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION MORTAR IS WASHED OUT AT VARIOUS LOCATIONS. | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION BROKEN WINDOW AT RESIDENTIAL DOOR. SOUTH ELEVATION BROKEN WINDOW. | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
PARAPET | PARAPET AT WEST ELEVATION HAS WASHED OUT MORTAR. | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
REPAIR ROOF | ROOF AT SOUTH ELAVTION HAS ROTTED PLYWOOD. | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH 2ND BROKEN PANE | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST DOOR BROKEN PANE | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | EAST AT 2ND WORN SASHES | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATION EXTERIOR WOOD PEELING PAINT | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | SOUTH ALLEY GUTTER RUSTED AND DAMAGE,MISSING DOWNSPOUT | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | ERECTING NEW 40FT X 80FT 1.5 STORY MASONRY VENEER CLASS "C" SMALL ASSEMBLY CHURCH. | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP WORK ON PREMISES UNTIL A BUILDING PERMIT IS OBTAINED (13-12-080) (13-32-035) | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PERMIT HAS BEEN OBTAINED 14A-3-306 | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | ERECTED A NEW 80FT X 80FT 1 STORY FRAME ASSEMBLY BUILDING GROUP A-3 INTENDED FOR PLACE OF RELIGIOUS WORSHIP | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | EXCEEDS ALLOWABE BUILDING AREA FOR OCCUPANCY CLASSIFICATION A-3 USING FRAME CONSTRUCTION (VA) IN A NON SPRINKLERED BUILDING 14B-506-2 | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH ELEVATION GUTTERS ARE DAMAGED, BENT AND NOT SECURE. WEST ELEVATION DOWNSPOUT HAS IMPROPER CONNECTION (BUILDING WALL SHOWS SIGNS OF ERROSION FROM WATER). | 4901 W FERDINAND ST | COMPLAINT | CLOSED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH GUTTER DAMAGE,MISSING DOWNSPOUT | 4901 W FERDINAND ST | COMPLAINT | FAILED | View |