OBSTRUCTIONS IN EXIT WAY | FRONT AREAWAY BLOCKED BY DEBRIS AND CONSTRUCTION MATERIAL | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRWAY UNDERSIZED HAND AND GUARDRAILS HORIZONTAL PICKETS | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR PORCH - COLUMNS ARE ERECTED ON PAVEMENT,COLUMNS ARE OVER NOTCHED, 2 X 8 BEAMS ARE INSUFFICIENT , LEDGER BOLTS ARE MISSING. 2 X 8 DECK JOIST ARE SPACED 24 INCHES APART AND ARE OVERSPANNED AT 12' FEET. RAILS ARE ONLY 36' INCHES HIGH OUT FASTENED USING ONLY NAILS . PLANS AND A PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS AND BATHROOM IN BASEMENT,1,2ND FLOORS UNITS 18-27-210.8 | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE COMMON AREA'S , BASEMENT AREA'S AND GARAGES - 18-27-210. 25 | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT WIRING, BOXES , FITTING, DEVICES AND ELECTRICAL EQUIPMENT INTALLED THRU OUT BASEMENT , 1,2 FLOOR AND COMMON AREA 13- 12- 380 | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View | |
NO PERMIT WIRING | OBTAIN PLANS AND PERMITS FOR INSTALLATION OF ELECTRICAL CONDUIT , BOXES , WIRING, FITTINGS DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THRU OUT BASEMENT , 1,2 FLOOR UNITS AND COMMON AREAS - | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR 2ND FLOOR PORCH DECK - ACCUMULATION OF STORAGE, TABLES, CHAIRS, LADDERS, ETC. - REMOVE | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIR SYSTEM - TREADS WEAK. BASEMENT STAIR SYSTEM - HANDRAIL LOOSE. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
KEEP FIXTUR CLEAN AND SANITARY | 1ST FLOOR APARTMENT - BATHROOM TUB PAINTED SURFACE PEELING AND RUSTED. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
INT WALL/CEILING PEELING PAINT | 1ST FLOOR APARTMENT - TUB ARE MILDEW BUILD-UP. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT (NEAR REAR DOOR) - IMPROPER PALLET TYPE WOOD USED AS STAIR SYSTEM. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL ALTERATIONS TO AUTHORIZE INTERIOR ALTERATION 1ST FLOOR AND BASEMENT, DUPLEXED 2ND FLOOR AND 1ST FLOOR COMPLETELY REHABBED. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | BASEMENT - WATER HEATER (2) RELIEF VALVE PIPES ARE PVC. THEY MUST BE METALLIC. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
OPEN | INSTALL SAFE PANS UNDER WATER HEATERS AND PIPE TO AN OPEN SITE WASTE. (18-29-504.8) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WASTE PIPING | LAVATORY WASTE HAS AN ACCORDION STYLE PIPE TO TRAP, REMOVE AND USE STRAIGHT TUBE PIPING. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
INSTALL TRAP,WASTE,VENT PIPES | LAUNDRY TUB - INSTALL A TRAP ON FIXTURE WASTE. DANGEROUS AND HAZARDOUS. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
INSTALL TRAP,WASTE,VENT PIPES | LAUNDRY TUB - REMOVE WASHER DISCHARGE PIPE FROM THE SAME HORIZONTAL WASTE LINE FOR LAUNDRY TUB AND PROPERLY TRAP AND VENT FOR THAT APPLIANCE. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PRV FLOOR DRAIN WITH METAL STR | INSTALL AN APPROVED FLOOR DRAIN COVER FOR DRAIN IN FRONT OF LAUNDRY TUB. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR DEFECTIVE FITTINGS | FIRST FLOOR BATHROOM, TUB SPOUT TOO FAR FROM WALL. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PROVIDE TRAP FOR FIXTURE | FIRST FLOOR KITCHEN SINK WASTE IS DOUBLE TRAPPED. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE PLBG FIXTURE | SECOND FLOOR - TUB VALVE ESCUTCHEON PLATE IS AWAY FROM THE WALL. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TRAP | KITCHEN SINK (SECOND FLOOR) REMOVE ACCORDION TRAP AND INSTALL A STRAIGHT TUB TRAP. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PROVIDE TRAP FOR FIXTURE | KITCHEN SINK (SECOND FLOOR) REMOVE WASHER PIPING FROM THE HORIZONTAL WASTE PIPE FOR THE KITCHEN SINK AND SEPARATELY TRAP AND VENT FOR WASHER. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE WATER PIPING | INSTALL AIR CHAMBERS FOR WASHER WATER SUPPLIES. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT ALL PLUMBING VIOLATIONS. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL IN BASEMENT REAR AREA. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE ARC FAULT BREAKERS FOR ALL BEDROOMS RECEPTACLES. (18-27-560.5(E) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
PROVIDE A MINIMUM OF 2 - 20 AMP SMALL APPLIANCE BRANCH CIRCUITS IN DWELLING UNITS TO SERVE REQUIRED RECEPTACLES. (18-27-560.6-(3B)-(1) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT, 1ST, 2ND FLOOR AREAS. (13-12-380) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View | |
SEE INSPECTOR COMMENTS | PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE. (18-27-210.25) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS OR PERMIT THROUGHOUT BASEMENT, 1ST, 2ND FLOOR AREAS. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR WOODEN FENCE- DAMAGED SECTIONS | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | NORTH ELEVATION/ ACCUMULATION OF TRASH AND DEBRIS | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR STOOP | FRONT STAIRS- CONCRETE STOOP BROKEN | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EXTERIOR WALLS- WASHED OUT MORTAR AND VERTICAL FRACTURES | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS- WASHED OUT MORTAR AND VERTICAL FRACTURES | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH/ COLUMN ERECTED ON SERVICE WALK, NO VISIBLE FOOTINGS. PICKETS SPACING MORE THAN 4" OC | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 1ST FLOOR TENANT- REFUSED ENTRY, UNVERIFIED DETECTORS AND OCCUPANCY | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING MAILING ADDRESS ON MANAGEMENT SIGN | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
REPAIR STOOP | FRONT STAIRS - CONCRETE STOOP BROKEN | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION SERVICE WALK - BROKEN AND UNEVEN CONCRETE. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS - WASHED OUT MORTAR AND VERTICAL FRACTURES. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR WOODEN FENCE - DAMAGED SECTIONS. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH - COLUMN ERECTED ON SERVICE WALK, NO VISIBLE FOOTINGS. PICKETS SPACING MORE THAN 4" MAXIMUM SPACING. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | MISSING MAILING ADDRESS ON MANAGEMENT SIGN. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR DOWNSPOUT | REAR DOWNSPOUT IS DISCONNECTED | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
PRV FLUE FOR HOT WATER HEATER | REPAIR BACK PITCHED FLUE PIPING ON WATER HEATER | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNERS ID. SIGN - MISSING ADDRESS INFORMATION | 2711 W LEXINGTON ST | COMPLAINT | CLOSED | View |
REPAIR LINTELS | NORTH ELEVATION - LINTELS RUSTED. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FLUSH DEVICE | FIRST FLOOR BATHROOM, TOILET IS RUNNING, DOESN'T SHUT OFF. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | LINTELS- RUSTED/ NORTH ELEVATION | 2711 W LEXINGTON ST | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | LAUNDRY TUB MISSING A SUPPORT LEG. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT FOR ALL PLUMBING VIOLATIONS. | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |
OPEN | INSTALL A FLOOR DRAIN IN THE SAME ROOM AS THE WATER HEATERS. (18-29-412.4) | 2711 W LEXINGTON ST | COMPLAINT | PASSED | View |