Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 10:44 PM
PIN: 16134080240000
Property Address: 2711 W LEXINGTON ST
City - Zip: CHICAGO - 60612
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77103
2023 Tax District: 77104
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 55 Violations
Violation Inspector Comments Address Category Status View
OBSTRUCTIONS IN EXIT WAY FRONT AREAWAY BLOCKED BY DEBRIS AND CONSTRUCTION MATERIAL 2711 W LEXINGTON ST COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR FRONT EXTERIOR STAIRWAY UNDERSIZED HAND AND GUARDRAILS HORIZONTAL PICKETS 2711 W LEXINGTON ST COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR PORCH - COLUMNS ARE ERECTED ON PAVEMENT,COLUMNS ARE OVER NOTCHED, 2 X 8 BEAMS ARE INSUFFICIENT , LEDGER BOLTS ARE MISSING. 2 X 8 DECK JOIST ARE SPACED 24 INCHES APART AND ARE OVERSPANNED AT 12' FEET. RAILS ARE ONLY 36' INCHES HIGH OUT FASTENED USING ONLY NAILS . PLANS AND A PERMIT ARE REQUIRED FOR PORCH REPAIRS. 2711 W LEXINGTON ST COMPLAINT CLOSED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS AND BATHROOM IN BASEMENT,1,2ND FLOORS UNITS 18-27-210.8 2711 W LEXINGTON ST COMPLAINT CLOSED View
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE COMMON AREA'S , BASEMENT AREA'S AND GARAGES - 18-27-210. 25 2711 W LEXINGTON ST COMPLAINT CLOSED View
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT WIRING, BOXES , FITTING, DEVICES AND ELECTRICAL EQUIPMENT INTALLED THRU OUT BASEMENT , 1,2 FLOOR AND COMMON AREA 13- 12- 380 2711 W LEXINGTON ST COMPLAINT CLOSED View
NO PERMIT WIRING OBTAIN PLANS AND PERMITS FOR INSTALLATION OF ELECTRICAL CONDUIT , BOXES , WIRING, FITTINGS DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THRU OUT BASEMENT , 1,2 FLOOR UNITS AND COMMON AREAS - 2711 W LEXINGTON ST COMPLAINT CLOSED View
OBSTRUCTIONS IN EXIT WAY REAR 2ND FLOOR PORCH DECK - ACCUMULATION OF STORAGE, TABLES, CHAIRS, LADDERS, ETC. - REMOVE 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIR SYSTEM - TREADS WEAK. BASEMENT STAIR SYSTEM - HANDRAIL LOOSE. 2711 W LEXINGTON ST COMPLAINT PASSED View
KEEP FIXTUR CLEAN AND SANITARY 1ST FLOOR APARTMENT - BATHROOM TUB PAINTED SURFACE PEELING AND RUSTED. 2711 W LEXINGTON ST COMPLAINT PASSED View
INT WALL/CEILING PEELING PAINT 1ST FLOOR APARTMENT - TUB ARE MILDEW BUILD-UP. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM BASEMENT (NEAR REAR DOOR) - IMPROPER PALLET TYPE WOOD USED AS STAIR SYSTEM. 2711 W LEXINGTON ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL ALTERATIONS TO AUTHORIZE INTERIOR ALTERATION 1ST FLOOR AND BASEMENT, DUPLEXED 2ND FLOOR AND 1ST FLOOR COMPLETELY REHABBED. 2711 W LEXINGTON ST COMPLAINT PASSED View
PRV DISCHARGE PIPE FROM PRV BASEMENT - WATER HEATER (2) RELIEF VALVE PIPES ARE PVC. THEY MUST BE METALLIC. 2711 W LEXINGTON ST COMPLAINT PASSED View
OPEN INSTALL SAFE PANS UNDER WATER HEATERS AND PIPE TO AN OPEN SITE WASTE. (18-29-504.8) 2711 W LEXINGTON ST COMPLAINT PASSED View
REPLACE DEFECTIVE WASTE PIPING LAVATORY WASTE HAS AN ACCORDION STYLE PIPE TO TRAP, REMOVE AND USE STRAIGHT TUBE PIPING. 2711 W LEXINGTON ST COMPLAINT PASSED View
INSTALL TRAP,WASTE,VENT PIPES LAUNDRY TUB - INSTALL A TRAP ON FIXTURE WASTE. DANGEROUS AND HAZARDOUS. 2711 W LEXINGTON ST COMPLAINT PASSED View
INSTALL TRAP,WASTE,VENT PIPES LAUNDRY TUB - REMOVE WASHER DISCHARGE PIPE FROM THE SAME HORIZONTAL WASTE LINE FOR LAUNDRY TUB AND PROPERLY TRAP AND VENT FOR THAT APPLIANCE. 2711 W LEXINGTON ST COMPLAINT PASSED View
PRV FLOOR DRAIN WITH METAL STR INSTALL AN APPROVED FLOOR DRAIN COVER FOR DRAIN IN FRONT OF LAUNDRY TUB. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR DEFECTIVE FITTINGS FIRST FLOOR BATHROOM, TUB SPOUT TOO FAR FROM WALL. 2711 W LEXINGTON ST COMPLAINT PASSED View
PROVIDE TRAP FOR FIXTURE FIRST FLOOR KITCHEN SINK WASTE IS DOUBLE TRAPPED. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPLACE DEFECTIVE PLBG FIXTURE SECOND FLOOR - TUB VALVE ESCUTCHEON PLATE IS AWAY FROM THE WALL. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPLACE DEFECTIVE TRAP KITCHEN SINK (SECOND FLOOR) REMOVE ACCORDION TRAP AND INSTALL A STRAIGHT TUB TRAP. 2711 W LEXINGTON ST COMPLAINT PASSED View
PROVIDE TRAP FOR FIXTURE KITCHEN SINK (SECOND FLOOR) REMOVE WASHER PIPING FROM THE HORIZONTAL WASTE PIPE FOR THE KITCHEN SINK AND SEPARATELY TRAP AND VENT FOR WASHER. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPLACE DEFECTIVE WATER PIPING INSTALL AIR CHAMBERS FOR WASHER WATER SUPPLIES. 2711 W LEXINGTON ST COMPLAINT PASSED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT ALL PLUMBING VIOLATIONS. 2711 W LEXINGTON ST COMPLAINT PASSED View
WORKING SPACE PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL IN BASEMENT REAR AREA. 2711 W LEXINGTON ST COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE ARC FAULT BREAKERS FOR ALL BEDROOMS RECEPTACLES. (18-27-560.5(E) 2711 W LEXINGTON ST COMPLAINT PASSED View
PROVIDE A MINIMUM OF 2 - 20 AMP SMALL APPLIANCE BRANCH CIRCUITS IN DWELLING UNITS TO SERVE REQUIRED RECEPTACLES. (18-27-560.6-(3B)-(1) 2711 W LEXINGTON ST COMPLAINT PASSED View
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT, 1ST, 2ND FLOOR AREAS. (13-12-380) 2711 W LEXINGTON ST COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE. (18-27-210.25) 2711 W LEXINGTON ST COMPLAINT PASSED View
NO PERMIT WIRING OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS OR PERMIT THROUGHOUT BASEMENT, 1ST, 2ND FLOOR AREAS. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR FENCE REAR WOODEN FENCE- DAMAGED SECTIONS 2711 W LEXINGTON ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE NORTH ELEVATION/ ACCUMULATION OF TRASH AND DEBRIS 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR STOOP FRONT STAIRS- CONCRETE STOOP BROKEN 2711 W LEXINGTON ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY EXTERIOR WALLS- WASHED OUT MORTAR AND VERTICAL FRACTURES 2711 W LEXINGTON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALLS- WASHED OUT MORTAR AND VERTICAL FRACTURES 2711 W LEXINGTON ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH/ COLUMN ERECTED ON SERVICE WALK, NO VISIBLE FOOTINGS. PICKETS SPACING MORE THAN 4" OC 2711 W LEXINGTON ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION 1ST FLOOR TENANT- REFUSED ENTRY, UNVERIFIED DETECTORS AND OCCUPANCY 2711 W LEXINGTON ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# MISSING MAILING ADDRESS ON MANAGEMENT SIGN 2711 W LEXINGTON ST COMPLAINT FAILED View
REPAIR STOOP FRONT STAIRS - CONCRETE STOOP BROKEN 2711 W LEXINGTON ST COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY EAST ELEVATION SERVICE WALK - BROKEN AND UNEVEN CONCRETE. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL EXTERIOR WALLS - WASHED OUT MORTAR AND VERTICAL FRACTURES. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR FENCE REAR WOODEN FENCE - DAMAGED SECTIONS. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH - COLUMN ERECTED ON SERVICE WALK, NO VISIBLE FOOTINGS. PICKETS SPACING MORE THAN 4" MAXIMUM SPACING. 2711 W LEXINGTON ST COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# MISSING MAILING ADDRESS ON MANAGEMENT SIGN. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR DOWNSPOUT REAR DOWNSPOUT IS DISCONNECTED 2711 W LEXINGTON ST COMPLAINT CLOSED View
PRV FLUE FOR HOT WATER HEATER REPAIR BACK PITCHED FLUE PIPING ON WATER HEATER 2711 W LEXINGTON ST COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING - OWNERS ID. SIGN - MISSING ADDRESS INFORMATION 2711 W LEXINGTON ST COMPLAINT CLOSED View
REPAIR LINTELS NORTH ELEVATION - LINTELS RUSTED. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPLACE DEFECTIVE FLUSH DEVICE FIRST FLOOR BATHROOM, TOILET IS RUNNING, DOESN'T SHUT OFF. 2711 W LEXINGTON ST COMPLAINT PASSED View
REPAIR LINTELS LINTELS- RUSTED/ NORTH ELEVATION 2711 W LEXINGTON ST COMPLAINT FAILED View
INSTALL FIXTURES PROPERLY LAUNDRY TUB MISSING A SUPPORT LEG. 2711 W LEXINGTON ST COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT FOR ALL PLUMBING VIOLATIONS. 2711 W LEXINGTON ST COMPLAINT PASSED View
OPEN INSTALL A FLOOR DRAIN IN THE SAME ROOM AS THE WATER HEATERS. (18-29-412.4) 2711 W LEXINGTON ST COMPLAINT PASSED View