Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SAFE WORKING CONDITIONS | APT. 3B: HEATING SYSTEM IS OUT OF SERVICE DURING TIME OF INSPECTION | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTHWEST DOOR AT PUBLIC WALK - WARPED AND BROKEN | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WEST AND COURTYARD ELEVATIONS - OPEN SILL JOINTS | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
PRV CAST IRON COVER FOR BASIN | CATCH BASIN (NORTH), MISSING COVER. | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | UNDER PORCHES, EXCESSIVE TRASH. | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST AND COURTYARD ELEVATIONS - FRACTURES, LOOSE AND OPEN JOINTS, LOOSE STONES WITH OPEN JOINTS ABOVE 3RD FLOOR WINDNOWS. | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | NORTH ELEVATION, EAST AND WEST PORCH SYSTEMS - LOOSE TREADS AND RISERS AT VARIOUS LOCATIONS, MISSING FOOTINGS/COLUMNS ON SLAB ONLY, OVERNOTCHED COLUMNS, NORTHEAST PORCH HAS A CRACKED AND SISTERED CORNER COLUMN, MISSING JOIST HANGARS AT VARIOUS LOCATIONS, NORTHWEST PORCH COLUMN AT CORNER ARE STACKED ON ALL FLOORS .PLANS AND PERMITS ARE REQUIRED FOR REPAIRS. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPAIR COPING | ALL ELEVATIONS -LOOSE AND MISSING COPINGS WITH OPEN JOINTS AT VARIOUS LOCATIONS | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2002-2006 | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION STEP FRACTURES | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION-ABOVE 3RD FLOOR-SOLDIER COURSE AND CORNICE SHIFTED | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES-JOIST ARE OVER SPANNED,LOOKOUTS PULLING FROM UPRIGHTS-NO VISIBLE FOOTINGS-WINDER TREADS ARE CUT TO ACCOMEDATE DOOR SWEEP-PLANS AND PERMIT-REQUIRED FOR REPAIRS OR REPLACEMENT | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | SERVICE WALK-RODENT HOLES | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
SEAL CONDUIT OPENING | PATCH HOLE AROUND CONDUIT-NORTH EXTERIOR AND AROUND SERVICE CONDUITS,IN THE BASEMENT | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | MISSING LB COVER D&H | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | UNDER EXTERIOR PORCHES DEMOLITION DEBRIS | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR-BROKEN PANE | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | MISSING JUNCTION BOX COVER-IN THE BASEMENT | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PARAPET | ALL ELEVATIONS -FRACTURES, LOOSE AND ERODED MORTAR. | 1511 S SPRINGFIELD AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR UNITS | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5' REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING HAS NEVER BEEN REGISTERED | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | COMMON STAIRWAY MISSING SMOKE DETECTOR | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | TWO NORTH WOOD FRAMED PORCHES HAVE 6X6 SUPPORT COLUMNS ON SLAB, UNEVEN RISER HEIGHTS, INCORRECT 6X6 BUILT SPLICES, 3X6 SUPPORT COLUMNS ON SLAB. NORTH EAST, WOOD, PORCH WILL REQUIRE 2 LOOKOUTS FROM BRICK POCKET TO 6X6 WOOD SUPPORT | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS/PERMITS ARE REQUIRED FOR REPAIR OR REPLACEMENT ON NORTH 3 STORY WOOD PORCHES | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | MAINTAIN SYSTEM III IN OPERABLE CONDITION | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS | 1511 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |