Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
WORK NOT ALLOWED | THE BASEMENT HAS BEEN ALTERED FROM THE ORIGINAL STORAGE SPACE TO A DWELLING UNIT. THE FRONT FOUNDATION WALL OF THE BUILDING HAS BEEN BREACHED TO ADD A FRONT STAIRWAY AND DOOR OPENING. REMOVE ALL PARTITIONS AND FIXTURES INSTALLED AT THE BASEMENT WITHOUT A PERMIT OR OBTAIN PERMIT FOR SAME. | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BUILDING OR RESTORE IT TO ITS ORIGINAL STATE. | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
CONTRARY TO ORIGINAL PLAN | ORIGINAL 2 DWELLING UNIT BUILDING CURRENTLY 3 DWELLING UNITS WITH THE USE OF THE BASEMENT AS AN APARTMENT. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT ORIGINALLY STORAGE CURRENTLY USED AS AN APARTMENT. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
STAIRWELL ENCLOSURE - BASEMENT | INSUFFICIENT STAIRWELL ENCLOSURE AT REAR EGRESS | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
WARNING IF WORK PERMITTED | ADVISORY ONLY | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
PRV CLEANOUT AT BASE OF STACK | BASEMENT - INSTALL A PROPER CLEAN-OUT AT THE BASE OF SOIL STACK | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | WATER HEATER, REPLACE THE PRE-RELIEF VALVE PIPING WITH APPROVED MATERIAL | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR CONDUIT RUNS APART AT FITTINGS THROUGHOUT BASEMENT AREAS | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS THROUGHOUT BASEMENT AREAS | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE ALL DEFECTIVE AND EXCESSIVE USE OF ARMORED CABLE THROUGHOUT BASEMENT AREAS. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
ALL BOXES SHALL BE ACCESSIBLE, COVERED, AND COMPLY WITH THE DIMENSION REQUIREMENTS OF ARTICLE 370. - THROUGHOUT BASEMENT AREA THERE ARE BURIED JUNCTION BOXES - 18-27-370 | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AREAS. 13-12-380 | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREA, AND GARAGE. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT AREAS WITHOUT PLANS OR PERMITS | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5'. REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER POSTING. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View | |
PRV BALLCOCK,VB,OR AIR GAP | SILCOCK EAST ELEVATION. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTER TOP AREAS, BATHROOMS, LAUNDRY AREAS. 18-27-210.8, 18-27-570.8 | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | STOP LEAKING WATER AT WATER HEATER | 906 N LECLAIRE AVE | COMPLAINT | PASSED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTERIOR CORD USE THROUGHOUT KITCHEN, LIVING ROOMS, BEDROOMS IN 2ND FLOOR UNIT AND THROUGHOUT BASEMENT | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING. | 906 N LECLAIRE AVE | COMPLAINT | FAILED | View |