Last Modification Date: 2024-10-22 @ 5:12 PM
PIN: 16241000370000
Property Address: 1238 S TROY ST
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 42 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# NO OWNER I.D SIGN POSTED. 1238 S TROY ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION 2 STORY WOOD PORCH HAS 2X8 JOIST SPANNING OVER (14FT),6X6 COLUMNS ARE OVERNOTCHED AND CENTER CONNECTION AT BEAM TO COLUMN IS PULLING AWAY,GUARDRAILS ARE UNDER 42" HIGH;TOENAILED TO COLUMNS AND MISSING INTERMEDIATE POSTS,FOUNDATIONS UNKNOWN SUBMIT PLANS AND OBTAIN PERMIT BEFORE REPAIRING OR REPLACING PORCH. 1238 S TROY ST COMPLAINT FAILED View
CHIMNEY SOUTH ELEVATION CHIMNEY HAS LOOSE AND MISSING BRICKS AT TOP.BL00831 1238 S TROY ST COMPLAINT FAILED View
CHIMNEY CAPPING SOUTH ELEVATION CHIMNEY CAP MISSING.BL00831 1238 S TROY ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE EXCESSIVE STORAGE OF PERSONAL ITEMS ON BACK PORCH. BL00831 1238 S TROY ST COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY NORTH ELEVATION GANGWAY HAS SPALLING AND BROKEN CONCRETE. 1238 S TROY ST COMPLAINT FAILED View
REPAIR CORNICE EAST ELEVATION STONE CORNICE HAS WASHED OUT MORTER JOINTS. BL00831 1238 S TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE EAST ELEVATION FRONT COMMON DOOR MISSING DOOR CLOSER. 1238 S TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR EAST ELEVATION FRONT COMMON ENTRY DOOR IS DELAMINATED. 1238 S TROY ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2ND FLOOR FRONT HALLWAY AT CEILING MISSIN SMOKE DETECTOR. 1238 S TROY ST COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 2ND FLOOR ENTRY DOOR MISSING PEEP HOLE. 1238 S TROY ST COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR WEST ELEVATION BACK GATE DOUBLE CYLINDER LOCK. 1238 S TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH AND NORTH ELEVATION OF BACK PORCH HAS BUCKLED AND WARPED VERTICAL SIDING. BL00831 1238 S TROY ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL ALL ELEVATIONS - FRACTURES, LOOSE AND ERODED MORTAR AT VARIOUS LOCATIONS. EAST LIMESTONE FACADE ELEVATION - FRACTURES, LOOSE AND SHIFTED LIMESTONES THRU-OUT.PLANS AND PERMITS ARE REQUIRED FOR LIMESTONE FACADE AND BALCONY REPAIRS/REBUILDS . ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. 1238 S TROY ST COMPLAINT CLOSED View
SAFE WORKING CONDITIONS 2ND FL. APT/ FURNACE - OUT OF SERVICE AT TIME OF INSPECTION. 1238 S TROY ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE 2ND FL. APT - USING PORTABLE ELECTRIC STOVE AND HEATING EQUIPMENT AS COOKING AND HEATING DEVICE. BOILING POTS OF HOT WATER ON A HOTPLATE. 1238 S TROY ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 2ND FL./APT - MISSING CARBON MONOXIDE DETECTOR. 1238 S TROY ST COMPLAINT FAILED View
REPAIR COPING ALL ELEVATIONS - OPEN COPING JOINTS 1238 S TROY ST COMPLAINT CLOSED View
SERVICE DROP OUT OF REACH SERVICE DROP WITHIN REACH OF PORCH REAR EXTERIOR DANGEROUS AND HAZARDOUS 1238 S TROY ST COMPLAINT PASSED View
STRAP SERVICE CONDUIT SUPPORT SERVICE RISER DANGEROUS AND HAZARDOUS REAR EXTERIOR 1238 S TROY ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR NORTH ELEVATION BACK STAIRS MISSING HANDRAIL. 1238 S TROY ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 2ND FL.APT/ GAS SERVICE - SHUT OFF, NO HEAT PROVIDED. 1238 S TROY ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 2ND FL. APT/ HOT WATER SUPPLIED AT ONLY 45 DEGREES. 1238 S TROY ST COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS ALL ELEVATIONS -MISSING OR TORN SCREENS 1238 S TROY ST COMPLAINT CLOSED View
MAINTAIN WINDOW ALL ELEVATIONS -ROTTED WINDOW FRAMES 1238 S TROY ST COMPLAINT CLOSED View
RATS REAR AND SIDE YARDS - VERY HIGH WEEDS , EXCESSIVE CARS,JUNK ,TIRES AND DEBRIS. RAT INFESTATION/HABORAGE. 1238 S TROY ST COMPLAINT CLOSED View
STOP/REMOVE NUISANCE REAR AND SIDE YARDS - VERY HIGH WEEDS , EXCESSIVE CARS,JUNK ,TIRES AND DEBRIS THRU-OUT.RAT HARBORAGE. 1238 S TROY ST COMPLAINT CLOSED View
PROTECT SIDEWALK DURING CONST EAST PUBLIC WALK - IMMEDIATELY PROVIDE EMERGENCY SCAFFOLDING OR PROTECTIVE CANOPY OVER THE PUBLIC WAY FOR THE PROTECTION OF PEDESTRIANS FROM UNSAFE BUILDING CONDITIONS AND PREVENT IMMINENT HARM TO PEOPLE OR PROPERTY. A BUILDING PERMIT APPLICATION COVERING THE SCOPE OF THE EMERGENCY REPAIR MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS ON THE NEXT BUSINESS DAY. A PERMIT APPLICATION FOR THE SCAFFOLDING/CANOPY MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS WITHIN 3 BUSINESS DAYS OF ERECTION. THE DEPARTMENT OF TRANSPORTATION MAY NOT ISSUE A PERMIT FOR USE OF THE PUBLIC WAY TO INSTALL SCAFFOLDING/CANOPY UNLESS A PERMIT FOR THE SCAFFOLDING/CANOPY HAS BEEN OBTAINED FROM THE BUILDING DEPARTMENT. (14A-4-401.1.1, 14A- 1238 S TROY ST COMPLAINT CLOSED View
STOP/REMOVE NUISANCE ABANDON CARS AT SIDE LOTS. 1238 S TROY ST COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS AT LOT VERY HIGH WEEDS. 1238 S TROY ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE ABANDON CARS AT SIDE LOTS. 1238 S TROY ST COMPLAINT CLOSED View
CUT OR REMOVE HIGH WEEDS AT LOT VERY HIGH WEEDS. 1238 S TROY ST COMPLAINT CLOSED View
REPAIR BALCONY EAST ELEVATION BALCONY - FRACTURES,LOOSE AND SHIFTED LIMESTONES AN COLUMNS. 1238 S TROY ST COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR EAST ELEVATION - SINKING TREAD AND RISER,UNEVEN RISER HEIGHTS. ONLY 3" BOTTOM STEP 1238 S TROY ST COMPLAINT CLOSED View
REPAIR FENCE SOUTH ELEVATION - BROKEN 6' WOOD FENCE, PERMIT REQUIRED FOR ALL 6' FENCES AND GATES. 1238 S TROY ST COMPLAINT CLOSED View
REPAIR EXTERIOR WALL NORTH AND SOUTH ELEVATION / EXTERIOR WALL - SPALLING BRICK WITH WASHED OUT MORTAR IN VARIOUS LOCATIONS. WEST ELEVATION / EXTERIOR WALL - LARGE GAPS AND HOLES WITH MISSING BRICKS AT WOOD PORCH ROOF POCKET BEAMS. 1238 S TROY ST COMPLAINT FAILED View
MAINTAIN WINDOW EAST ELEVATION / WINDOW - BOARDED UP AT BASEMENT.SOUTH ELEVATION / WINDOW - WOOD ROTTED WITH MISSING CAPPING AT 2ND FLOOR. 1238 S TROY ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED WEST ELEVATION / GARAGE - EAVES ROTTING THROUGHOUT. STEP CRACKS IN MASONRY THROUGHOUT. OVERHEAD DOOR HEADER - SAGGING. DOWNSPOUTS AND GUTTER MISSING. 1238 S TROY ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE SOUTH ELEVATION / APROX. 10 ABANDONED VEHICLES STORED ON SIDE OF BUILDING, WITH MANY TIRES SCATTERED THROUGHOUT. OVERGROWN VEGETATION THROUGHOUT.NORTH ELEVATION / MANY TIRES AND GARBAGE STOCKPILED ALONG SIDE OF BUILDING. 1238 S TROY ST COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS / SCREENS - MISSING AND TORN. 1238 S TROY ST COMPLAINT FAILED View
CHIMNEY NORTH ELEVATION / CHIMNEY - SPALLED MASONRY WITH WASHED OUT MORTAR. 1238 S TROY ST COMPLAINT FAILED View
REPAIR FENCE SOUTH AND WEST ELEVATIONS / FENCE - MISSING SECTIONS, LOOSE AND LEANING OUT OF PLUMB. 1238 S TROY ST COMPLAINT FAILED View