The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL COVERS | 2ND FLOOR APARTMENT | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | 2ND FLOOR RECEPTACLES THROUGHOUT | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SMOKE & CARBON DETECTORS | 2ND FLOOR | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | FRONT STAIRWELL, 2ND FLOOR APARTMENT(DANGEROUS AND HAZARDOUS) | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | 2ND FLOOR | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 2ND FLOOR THROUGHOUT (DANGEROUS AND HAZARDOUS) | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 2ND FLOOR THROUGHOUT (DANGEROUS AND HAZARDOUD) | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | APT. #2- HOT WATER SUPPLIED AT ONLY 52F. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | APT. #2- MISSING CARBON MONOXIDE DETECTOR. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APARTMENT #2 &-FRONT AND REAR STAIRWAYS-MISSING SMOKE DETECTORS. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APT. #2-ROOM TEMPERATURE-LIVING ROOM-64F., BEDROOM 62F., KITCHEN 62F., AT 12:54PM.INDIVIDUAL FORCED AIR FURNACE IS OFF AT TIME OF INSPECTION,NO HEAT PROVIDED. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | APT. #2-FURNACE-OUT OF SERVICE AT TIME OF INSPECTION. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2261 S KILDARE 2ND FLOOR APARTMENT FORCED AIR FURNACE OUT OF SERVICE AT TIME OF INSPECTION.(8:40AM). | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | 2261 S KILDARE 2ND FLOOR APARTMENT - NO RUNNING WATYER OUT OF KITCHEN AND VANITY FAUCETS.(8:40AM).(14X-9-905.4) | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2261 2ND FLOOR APARTMENT - NO RUNNING WATER OUT OF KITCHEN AND VANITY FAUCETS. (8:40AM).(14X-9-905.2, 14X-9-905.2.1 AND 14X-9-905.5). | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2261 S KILDARE 2ND FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING(14X-5-504.9, 14B-9915.1.1, 14B-9-915.2, AND 14R-11-1105) . . | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2261 S KILDARE 2ND FLOOR APARTMENT. KITCHEN IS 48 DEGREES. (8:40AM). FAMILY ROOM IS (44 DEGREES. (8:40AM). (14X-8-802.2, 14X-8-802.2.1 AND 14X-8-802.2.2). | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY WOOD PORCH.: COLUMNS ERECTED ON TOP OF STONES; FOUNDATION STATUS UNKNOWN.; UNDERSIZED 6"X6" BEAMS SPAN 6'-5" AND ARE TOENAILED TO COLUMNS.; UNSERSIZED 2"X8" DECK JOISTS SPAN 9'-8".; LANDING JOISTS ARE ONLY FACE-NAILED.; GUARDRAILS ARE ONLY 35" HIGH, LOOSE AND PULLING; END POSTS TO WALL ARE FASTENED WITH NAILS ONLY.: STRINGERS ARE FASTENED WITH NAILS ONLY.; TREADS ARE ONLY 9-3/8" WIDE.; DECK BOARDS ARE BUCKING.PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | 3RD FLOOR REAR APT. - BEDROOM WINDOW MISSING SASH. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | FRONT INTERIOR STAIRWAY, 1ST FLOOR AND 3RD FLOOR REAR APT. - WALLS AND CEILINGS THRU OUT PEELING PAINT. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING CHIP PLASTER | FRONT INTERIOR STAIRWAY 3RD FLOOR CEILING AND 3RD FLOOR REAR APT., KITCHEN CEILING - EXPOSED WOOD LATH. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - WASHED OUT MORTAR.NORTHEAST CORNER 3RD FLOOR - FACE STONES ARE SHIFTING OUT. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
PARAPET | SOUTH PARAPET - SPALLING BRICKS. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
CUT OR REMOVE HIGH WEEDS | REAR YARD - HIGH WEEDS. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - ROOF CAVED IN, WALLS HAVE STEP CRACKS ARE LEANING OUT AND HAVE LOOSE CINDER BLOCK.PERMIT REQUIRED TO WRECK GARAGE. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
PROVIDE COLD WATER TO FICTURES | BUILDING - NO COLD WATER PROVIDED.PIPES BUSTED IN THE BASEMENT PER OWNER (NO ENTRY).BUILDING HAS 5 D.U ONLY TWO ARE OCCUPIED 1ST FLOOR AND 3RD REAR. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | BUILDING - NO HOT WATER PROVIDED, INCLUDING 1ST FLOOR AND 3RD REAR. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | 1ST FLOOR AND 3RD FLOOR REAR APT. - USING GAS STOVE TO KEEP APT. WARM.BOILER IS BROKEN. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APT., SMOKE DETECTOR - MISSING BATTERY. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMOKE DETECTOR. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |
NO POSTED ADDRESS | BUILDING MISSING ADDRESS. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST ROOF EAVES - PEELING PAINT. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH, SOUTH AND FRONT PORCH GUTTERS AND DOWNSPOUTS - RUSTED WITH HOLES AND MISSING SECTIONS. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS TORN, DETERIORATED AND MISSING SHINGLES. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 1ST FLOOR - BROKEN WINDOW PANE. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS AND LEVELS WINDOWS - PEELING PAINT. NORTH ELEVATION 2ND FLOOR - ROTTED WINDOW MOULDING. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT MAIN AND SOUTH EXTERIOR DOORS - BROKEN WITH PEELING PAINT. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY WOOD PORCH: LEDGER BOARD FASTENED TO EXTERIOR WALL WITH NAILS ONLY.; UNDERSIZED 2"X6" DECK JOISTS SPAN UP TO 11'-0" AND ARE ONLY FACE NAILED.; COLUMNS ERECTED ON SOIL.; STRINGERS ARE FASTENED WITH NAILS ONLY.; HANDRAILS HAVE HORIZONTAL RAILS 7-1/2" APART AND ARE LOOSE.; GUARDRAILS ARE ONLY 33-1/2" HIGH.; PORCH HAS PEELING PAINT. PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH SERVICE WALK - CONCRETE HAS HOLES AND SECTIONS ARE SHIFTING. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK UNDER FRONT PORCH. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST FENCE MISSING TOP POLES. | 2261 S KILDARE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - REFUSE ACCUMULATION. | 2261 S KILDARE AVE | COMPLAINT | CLOSED | View |