Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-21 @ 11:16 PM
PIN: 16104160030000
Property Address: 4053 W MAYPOLE AVE
City - Zip: CHICAGO - 60624
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77100
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM FRONT PORCH, NO FOUNDATION-COLUMNS RESTING ON WOOD BLOCKS. LIGHT GAGE METAL STRAP SHEATHS USED TO CONNECT LOOK OUT BEAMS AND COLUMNS. COLUMNS BOWING OUTWARD AND RAILING/GUARDRAIL HEIGHT BELOW 42" HIGH. FULL PLANS AND PERMIT IS REQUIRED FOR REPAIRS. 4053 W MAYPOLE AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY BROKEN CONCRETE WALKWAY. 4053 W MAYPOLE AVE COMPLAINT FAILED View
RATS RATS-4053/APT3. 4053 W MAYPOLE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT AND REAR GATES PADLOCKED WITH KEY CHAINS. 4053 W MAYPOLE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNERSHIP I.D. SING NOT POSTED. 4053 W MAYPOLE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION BSMT TO GRADE STAIRWAY AT GANGWAY MISSING HANDRAILS. ALSO, BROKEN CONCRETE STEPS AT FRONT AND WEST STAIRWAYS. 4053 W MAYPOLE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS SOUTH ELEVATION BSMT TO GRADE STAIRWAY AT GANGWAY MISSING HANDRAILS, ALSO BROKEN CONCRETE STEPS AT FRONT AND WEST STAIRWAYS. 4053 W MAYPOLE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT PORCH: SEVERELY ROTTED DECKBOARD, RAILS, RISERS AND TREADS. NO FOUNDATION-ALL COLUMN RESTING O WOOD BLOCK AND SERVICE WALKWAY. NO JOIST HANGERS; NO BOLTS ON LEDGER BOARD. THE ENTIRE PORCH SYSTEM SHAKING. RAILING/GUARDRAILS BELOW 42" HIGH, REQUIRES PLANS AND PERMITS FOR REPAIRS. WEST COLUMN ROTTED AND BOWING! NO BEAM TO COLUMN CONNECTIONS. 4053 W MAYPOLE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING- NO OWNER'S ID SIGN POSTED. 4053 W MAYPOLE AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR EXTERIOR PORCH- 4X4 COLUMNS/HALF- LAP JOINTS WITH OVERLAP OF ONLY 8INCHES AND NAILS ONLY. UNDERSIZED 2X8 DECK JOINTS SPAN 13 FEET 2 INCHES. STRINGERS AT CORNER SOUTHWEST COLUMN INADEQUATELY SUPPORTED. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED THROUGHOUT RAILING SECTION WEAK AND PULLING, WITH LOOSE BOTTOM RAILS. DECK WEAK, WITH PULLING BOARDS. TREADS ONLY 9 1/2 INCHES WIDE. PLANS AND PERMIT REQUIRED FOR COMPLETE PORCH REPLACEMENT. 4053 W MAYPOLE AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWAY- MISSING HANDRAIL SECTIONS. 4053 W MAYPOLE AVE COMPLAINT PASSED View
INSTALL DOOR VIEWING DEVICE ALL APARTMENTS/FRONT ENTRANCE DOORS- MISSING VIEWING DEVICE. 4053 W MAYPOLE AVE COMPLAINT PASSED View
INSTALL DEAD BOLT LOCK ALL APARTMENTS/FRONT ENTRANCE DOORS- MISSING DEADBOLTS LOCKS. 4053 W MAYPOLE AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRWAY- MISSING SMOKE DETECTOR. 4053 W MAYPOLE AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING APT. 2- NO ENTRY, UNABLE TO VERIFY COMPLAINT OF MOLD UNDER SINK, FIXTURE HANGING AND MAGGOTS AT BEDROOM. 4053 W MAYPOLE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID SIGN POSTED. 4053 W MAYPOLE AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS BUILDING FRONT MISSING MORTAR ON WINDOWS SILLS. 4053 W MAYPOLE AVE COMPLAINT FAILED View