The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN IS NOT POSTED. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | GATES- CHAINED AND PADLOCKED. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS- TORN; MISSING. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES- BROKEN. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES- WORN. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES- WORN. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL- LOOSE; TORN; MISSING SECTION OF SIDING; SHARP EDGES. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE,UNABLE TO GAIN ENTRY TO 2ND FLOOR APARTMENT TO VERIFY COMPLAINT OF MICE AND CAVED IN CEILING.UNVERIFIED DETECTORS AND CONDITIONS. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
REMOVE | (7 - 28 - 060)WEST ELEVATION - 6FTX20FT CYCLONE GATE BUILT 3FT OFF OF OVERHEAD DOOR. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1ST FLOOR APARTMENT/ EXPOSED WIRING AT CEILING FROM HALLWAY TO KITCHEN. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
MAINTAIN PROJECTIONS | AWNING- BROKEN. | 2432 S DRAKE AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS/ PARAPET WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR 2-STORY ENCLOSED PORCH - UNDERSIZED 2X8 JOISTS SPAN 12'. EXTERIOR WALLS, DECK BOARDS AND STAIRS ROTTED; DANGER OF COLLAPSE. UNDERSIZED 2X8 ROOF JOISTS SPAN 10' STRINGERS UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY. ENTIRE PORCH ONLY NAILED AND SCREWED. PORCH STICKERED DANGEROUS AND HAZARDOUS.PLANS AND PERMIT REQUIRED TO REPLACE REAR ENCLOSED PORCH.FRONT 1-STORY WOOD PORCH - 4X4 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN. RAILINGS ONLY 34" HIGH. JOIST HANGERS FASTENED TO LEDGER BOARD WITH INTERIOR DRYWALL SCREWS. STRINGERS CUT WRONG; TREADS SHIMMED AT TREAD CUT, LOOSE AND UNSTABLE. STRINGERS UPPER ENDS INADEQUATELY SUPPORTED WITH JOIST HANGERS ONLY. ONLY ONE BOLT AT RIM JOIST TO COLUMN CONNECTIONS. NO STEEL ANGLE SUPPORT BRACKETS AT COLUMNS.PORCH PAINTED WITH HIGH GLOSS PAINT: SLIP HAZARD.PLANS AND PERMIT REQUIRED TO REPAIR FRONT PORCH. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | REAR ELEVATION/ ENCLOSED PORCH WINDOWS - ROTTED AND CRACKED. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR ENCLOSED PORCH/ 1ST AND 2ND FLOORS - BEING USED AT STORAGE. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APARTMENT - MISSING CARBON MONOXIDE DETECTOR. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APARTMENT AND REAR ENCLOSED PORCH - SMOKE DETECTOR MISSING. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
STOP SMOKE, NOXIOUS ODORS | REAR ENCLOSED PORCH - NOXIOUS ODORS AT 1ST FLOOR. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | GARAGE/ WINDOWS - BROKEN | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION BASEMENT TO GRADE/ GUARD RAIL - MISSING. | 2432 S DRAKE AVE | COMPLAINT | PASSED | View |