REPAIR PORCH SYSTEM | REAR PORCH AT LANDING VERY WEAK AND SHAKING, SCREWS PULLING OUTWARD, STRINGER NAIL AND COLUMNS REST ON SIDE WALL.PERMIT REQUIRE FOR PORCH REPAIR. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH FRONT STAIR -CONCRETE STEPS, AT LANDING SPLIT AND WARP WOOD. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR CATCH BASIN MISSING COVER. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR WOOD STAIRS GUARD RAILING END POST TO WALL FASTENED WITH TAP-CON TYPE SCREWS ONLY.FRONT METAL STAIRS - RUSTED SECTIONS. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO ENTRY, NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION / 1ST FLOOR WINDOW/WINDOW - GLASS WINDOW PANE CRACKED IN TOP SECTION. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN ACCESS TO INTERIOR OF BUILDING TO INSPECT CONDITIONS OF APTS, STAIR SYSTEMS AND SMOKE AND CARBON MONOXIDE DETECTORS. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | 3 STORY MASONRY BUILDING NORTH ELEVATION / REAR FRAMED PORCH / GRADE TO 2ND FLOOR/6X6 COLUMNS - CRACKING, TWISTING AND INADEQUATELY SUPPORTING LANDINGS. HARDWARE UNDERSIZED AND RUSTING. FOUNDATION STATUS UNKNOWN, COLUMNS SITTING ON CONCRETE SLAB.LEDGER - INADEQUATELY ANCHORED TO EXTERIOR WALL WITH UNDERSIZED, RUSTING HARDWARE.STRINGERS - CRACKING, BROKEN / MISSING SECTION AT 1ST LANDING GOING TO 2ND FLOOR LANDING. SECTION TIED OFF WITH CAUTION TAP AT OPEN SECTION UPON ARRIVAL.TREADS - LOOSE, CUPPING AND CRACKING WITH BROKEN / MISSING SECTION. SEVERELY WEATHERED FASTENED WITH PROTRUDING, RUSTING NAILS.DECK BOARDS - LOOSE, CUPPING AND CRACKING WITH BROKEN / MISSING SECTION. SEVERELY WEATHERED FASTENED WITH PROTRUDING, RUSTING NAILS.HANDRAIL / GUARDRAILS - LOOSE, CRACKING, SEVERELY WEATHERED WITH MISSING /BROKEN PICKETS IN VARIOUS LOCATIONS. FASTENED WITH RUSTING NAILNGS THROUGHOUT.PLANS AND PERMITS REQUIRED FOR REPLACEMENTS OF EXTERIOR PORCH SYSTEM. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION / FRONT WROUGHT IRON FENCE/FENCE - LEANING INWARD OUT OF PLUMB, GATE PROPED OPEN STUCK IN DIRT.SOUTH ELEVATION / REAR CHAIN LINK FENCE /FENCE - MISSING CROSS MEMEBERS AND GATE. BROKEN / LEANING OUT OF PLUMB. | 3022 W JACKSON BLVD | COMPLAINT | FAILED | View |