The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | 7839 S INGLESIDE AVE | COMPLAINT | CLOSED | View | |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTH ELEVATION / GUARDRAIL MEASURES ONLY 32 INCHES HIGH WITH GAPS UP TO 14 INCHES APART. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION / 1ST FLOOR WINDOW - BULLET HOLE. EAST ELEVATION / ATTIC WINDOW BOARDED WITH PLYWOOD. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 4X5 FOOT WOOD PORCH / COLUMNS ERECTED ON CONCRETE SLAB. FOUNDATION STATUS - UNKNOWN. COLUMNS - LEANING OUT OF PLUMB. COLUMNS - NOTCHED OUT END JOIST CONNECTION.ENTIRE STRUCTURE IS UNSTABLE AND MOVES WHEN WALKED UPON. JOISTS AND UPPER STRINGER CONNECTIONS - FASTENED WITH NAILS ONLY. PORCH NEEDS TO BE REPLACED. NO PERMIT REQUIRED FOR SMALL PORCH.WEST ELEVATION / 1 STORY WOOD PORCH WITH ROOF / DECK STRUCTURE IS SAGGING IN CENTER. CENTER MASNORY COLUMN - SHIFTED AND LEANING OUT OF PLUMB. CENTER BEAM CONSISTS OF SINGLE 2X8 THAT SPANS 67 INCHES LONG. STRINGERS SPACED UP TO 53 INCHES APART. GUARD RAILS - SPACED UP TO 88 INCHES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPLACE FRONT WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH ELEVATION / BASEMENT DOOR - ROTTING AND DELAMINATED WOOD. DOOR IS HELD SHUT WITH 2X4 WEDGED BETWEEN BACK OF DOOR AND FOUNDATION WALL. FRONT ENTRY DOOR WEATHER STRIP - LOOSE ( AIR SEEPAGE ). | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | BUILDING / ROOF - ROTTING AND DETERIORATED SHINGLES. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR AND BASEMENT / SMOKE DETECTORS - MISSING. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT / CARBON MONOXIDE DETECTOR - MISSING. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | 1ST FLOOR DECK SYSTEM IS SAGGING NEAR BEARING WALL UP TO 2 INCHES. FLOOR APPEARS TO BE WEAK. SOME 1ST FLOOR JOISTS ARE CRACKED AND WOOD POST SHOW SIGNS OF TERMITE DAMAGE. SUBMIT ENGINEERING REPORT ON THE STABILITY OF ENTIRE DECK STRUCTURE. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 1ST FLOOR AND BASEMENT / WALLS AND CEILINGS - DAMAGED, SAGGING WITH POORLY INSTALLED DRYWALL. BASEMENT WALLS HAVE BLACK SUBSTANCE ON SURFACES. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BUILDING THROUGHOUT - MICE. MICE -OBSERVED AT BASEMENT. MOUSE DROPPINGS AND MOUSE HOLES OBSERVED UNDER STOVE. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
INSECTS | BASEMENT JOISTS AND WOOD POST SHOW SIGNS OF SEVER TERMITE DAMAGE. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT STAIRS - CRACKED RISERS. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | BASEMENT - FOUL DAMP MUSTY SMELL THROUGHOUT. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | BUILDING / EXTERIOR WALLS - LOOSE AND BULGING VINYL SIDING WITH HOLES AT GRADE. NORTH EXTERIOR WALL IS COVERED WITH GREEN ALGEA. | 7839 S INGLESIDE AVE | COMPLAINT | FAILED | View |