Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SUBMIT FOR APPROVAL PLANS | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
POST OWNER NAME OF VACNT BLDG | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
FILE BLDG REGISTRATION | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION NUMEROUS BROKEN WINDOWS. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION SILL AT 3 OVER ENTRY FRACTURED. EAST ELEVATION BASEMENT SILL FRACTURED AS WELL AS SILL AT 1. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION OFF OF LINTELS- FRACTURES AND LOOSE MORTAR - MOST SIGNIFICANT OFF OF BASEMENT LINTELS- STEP FRACTURES, LOOSE MORTAR. NORTH ELEVATION AT 3 EAST END FRACTURED LIMESTONE OVER WINDOW, SHIFTING. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | EAST ELEVATION BASEMENT LINTELS RUSTING ASND SAGGING. OTHER LINTELS CAPPED AND CONDITIONS NOT VISIBLE. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH BEAM ANGLES ONLY 3/16" THICK. BASMENT GUARDRAILS MISSING PICKETS. LANDING COLUMNS NOTCHED ON 2 SIDES, AND NO BARRIER TO PROTECT COLUMNS FROM CARS PARKING IN LOT. SIGNIFICANT LATERAL SWAY. CUPPING TREADS WITH POPPING NAILS. RISER HEIGHTS VARY FROM 6'' TO 9 1/4''. AT LANDING BEAM BEFORE 3, COLUMN NOTCHED FOR LANDING BEAM AND COLUMN SPLICE IN CLOSE PROXIMITY, RESULTING IN COLUMN FRACTURES. PICKETS ON OUTSIDE OF RAIL SYSTEM. RAILS SPLITTING WITH LOOSE MEMBERS. OBTAIN COMPLETE PLAN AND PERMIT. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - ERODING MORTAR, FRACTURES, SPALLING BRICK. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INSPECT SR#19-0903161 | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INSPECT SR#19-0095210 | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 4906 N WHIPPLE ST | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING,NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS.UNVERIFIED COMPLAINT OF A ROOF LEAK IN APARTMENT #2-AND #3. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH ELEVATION /LINTEL - WAVY WITH LARGE GAP PACKED WITH MORTAR; FRACTURE IN PACKED MORTAR SECTION. NORTH ELEVATION /LINTEL - GAP PACKED WITH MORTAR. PLANS AND PERMIT REQUIRED FOR LINTEL REPLACEMENT OVER 6FT. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION /EXTERIOR WALL - LARGE VERTICAL MASONRY FRACTURES WITH OPEN MORTAR JOINTS. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION /PARAPET - CRACKED, CRUMBLING PARGE COAT WITH EXPOSED SPALLED BRICK SECTIONS BENEATH. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF FAULTY SMOKE DETECTOR. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR ELEVATION /METAL ROLLER GATE AND STRUCTURE - ERECTED OVER 5FT WITH NO PLANS OR PERMIT ON FILE. PLANS AND PERMIT NOW REQUIRED FOR SAID CONSTRUCTION. | 4906 N WHIPPLE ST | COMPLAINT | FAILED | View |