The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR INSPECTION | CONTACT INSPECTOR ROBINSON AT 312-446-5589. | 5726 N NAGLE AVE | PERIODIC | PASSED | View |
ACCESS TO ROOF | 5726 N NAGLE AVE | PERIODIC | PASSED | View | |
SEND EX. METAL LETTER | 5726 N NAGLE AVE | COMPLAINT | FAILED | View | |
F.E. MIDRAIL | 5726 N NAGLE AVE | COMPLAINT | FAILED | View | |
REPAIR DOWNSPOUT | TWO OVERHEAD PUMP CANOPIES , DOWNSPOUTS SMASHED , LOOSE AND DENTED . | 5726 N NAGLE AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | BRICKS , CONCRETE BLOCKS AND TRASH PILED AT FRONT AREAWAY AT WEST BETWEEN CARWASH BUILDING AND GAS STATION . RAT HARBORAGE . | 5726 N NAGLE AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | FRONT PUMP AREA AND PARKING LOT . CONCRETE AREAS SPALLED CONCRETE , FRACTURED AND DISPLACED CONCRETE . PAVED AREAS WORN AND WEATHERED PAVEMENT COATING , MISSING ALL PARKING LOT STRIPES . | 5726 N NAGLE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | TWO OVERHEAD GAS STATION PUMP CANOPIES , SUPPORT UPRIGHTS SEVERELY RUSTED AND DETERIORATED . EAST CANOPY , EAST MOST UPRIGHT COLUMN RUSTED OFF AT BASE WITH CANOPY TWISTING AND ROTATING UNDER WIND LOAD . IN DANGER OF COLLAPSE WITH CFD ON SCENE , GAS STATION CLOSED BY CFD WITH RIGHT LANES OF TRAFFIC CLOSED ON NORTH NAGLE AND NORTH NORTHWEST HWY BY STREETS AND SANITATION . TEMPORARY STABILIZATION OF CANOPY COMPLETED BY POPULAR IRON WORKS . PROVIDE PLANS AND PERMITS FOR PERMANENT REPAIRS TO IRON UPRIGHTS AND FOUNDATION STRUCTURES. | 5726 N NAGLE AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE 100% HANDS ON INSPECTION FOR TWO OVERHEAD PUMP CANOPIES , ALL COLUMNS AND SUPPORTS , FOUNDATIONS AND ALL EXPOSED METAL AS REQUIRED PER SECTION 13-196-030 , 13-96-820 , 13-96-830 , 13-96-840 , 13-96-850 AND 13-96-870 . SUBMIT TO : DEPARTMENT OF BUILDINGS , ATTN: JOSE APARICIO , 2045 W. WASHINGTON . | 5726 N NAGLE AVE | COMPLAINT | FAILED | View |