Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 911 W UPRIGHTS SOME MISSING FOOTINGS ,ROTTED AND SCABBED AT FIRE CUTS AND BASE, STRINGERS ROTTED ,SCABBED RAILINGS TO LOW ,ROTTED AND LOOSE ,STRINGERS MISSING BOLTS,3358 N. UPRIGHTS IMPROPER SIZE AND CONNECTION/BUTT JOINTS /FLOOR UNDERSIZE.SUBMIT PLANS & PERMITS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PARAPET | WASHED OUT MORTAR PARAPET WALL REAR ELEVATION . | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CHIMNEY | SPALLING BRICK REAR PARAPET WALL. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2 SOUTH PORCHES UNDERSIZED GUARD RAILS, INSUFFICIENT RAILING ARCHORS. INSUFFICIENT BEAM TO COLUMN CONNECTIONS. ROTTING DECKING WARPED & BUCKLED. STRINGERS NOT BOLTED TO MASONRY STRINGERS NOT BOLTED TO OTHER WOOD MEMBERS. SOUTH WEST PORCH WITH ROTTING RIM JOISTS AT 3 LEDGER BOARDS WITH OUT BOLTS & JOISTS WITHOUT JOIST HANGERS. SOUTH EAST PORCH WITH SEPARATING BEAM & JOIST AT 3 & ALSO MISSING JOIST HANGERS & LEDGER BOLTS. ROTTING STRINGER. BOTH PORCHES WITH ROTTING WOOD VARIOUS LOCATIONS. NO OTHER PORCHES ACCESSED OR VISIBLE. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
COMPLETE WORK | PERMIT FOR PORCHES OBTAINED BUT PORCHES HAVE NOT BEEN COMPLETED. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | SR#801262994 REAR SERVICE AREA CLOGGED FLOOR DRAIN. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | LAUNDRY ROOM CEILING HOLE | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING YEARS 2004 THROUGHOUT 2008 | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSPECT CONSTRUCTION WORK | ARRANGE FOR INSPECTION OF ALL 5 REAR PORCHES WHEN WORK IS COMPLETED ACCORDING TO PLANS & PERMIT (PERMIT FOR 5 PORCHES TO BE REPLACED) 100182174 | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PARAPET | SOTH ELEVATION REAR PORCH COURTYARD ELEVATIONS: PARAPET WALL SEVERELY SPALLED BRICK & ERODED MORTAR, SHIFTING BRICKS | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION & REAR PORCH COURTYARD ELEVATIONS: ERODED MORTAR & FRACTURES, SPALLED BRICK VARIOUS LOCATIONS, EAST ELEVATION TOWARDS NORTH END OPEN MORTAR JOINTS & FRACTURES RESULTING FROM RUSTING LINTEL, NORTH ELEVATION FRACTURES, OPEN MORTAR JOINTS & LOOSE MORTAR AT 1, 2, & 3 RESULTING FROM RUSTING & SAGGING LINTELS | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH & EAST ELEVATIONS RUSTING LINTELS, NORTH ELEVATION LINTELS ALSO SAGGING, BUCKLING OVER WINDOWS AT 1 | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY RESIDENTIAL PORTION OF BUILDING UNITS | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | GAS FURNANCE IN BEDROOM NEED TO ENCLOSE WITH PARTITION AND DOOR AND CEILING WITH AT LEAST 1 HOUR FIRE RATING IN APARTMENT 3 AT 911 W IRVING PARK ADDRESS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 911 W IRVING PARK APARTMENTS 3 HAS MOLD ON TILE IN BATHROOM-MAKE SANITARY CONDITION. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | 1ST FLOOR 903 ADDRESS IN BASEMENT CRAWL SPACE OPEN ELECTRICAL BOXES. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR 903 ADDRESS BASEMENT FURNANCE MISSING CARBON MONOXIDE DETECTOR. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 1ST FLOOR 903, ADDRESS BASEMENT GRADE TO BASEMENT MISSING HANDRAIL AT STAIRS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | 901 ADDRESS AT 1ST FRONT MISSING EXIST SIGN. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | INNER COURT YARD 3944-3958 N FREEMONT ADDRESSES BRICKS ON WINDOW SILLS PAPERS STREWN ABOUT IN COURTYARD AT GRADE. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR LINTELS | NORTH & EAST ELEVATIONS RUSTING LINTELS, NORTH ELEVATION LINTELS ALSO SAGGING, BUCKLING OVER WINDOWS AT 1 | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | GAS FURNANCE IN BEDROOM NEED TO ENCLOSE WITH PARTITION AND DOOR AND CEILING WITH AT LEAST 1 HOUR FIRE RATING IN APARTMENT 3 AT 911 W IRVING PARK ADDRESS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | INTERIOR 911 3RD FLOOR PROVIDE WORKING CARBON MONOXIDE DETECTOR. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | INTERIOR 911 3RD FL APARTMENT FURNACE ROOM MISSING "B" CLASS DOOR. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSECTS | INTERIOR BASEMENT 901-903 BUGS FROM EXCESSIVE DEBRIS PILE UP IN BASEMENT. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR 911 3RD FL PROVIDE WORKING SMOKE DETECTOR. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | INTERIOR BASEMENT 911 SEWER ODER. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT 901-903 EXCESSIVE GABAGE AND DEBRIS | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
EXPOSED WIRING | 909-11 W IRVING PARK BASEMENT | 901 W IRVING PARK RD | COMPLAINT | PASSED | View |
INSTALL COVERS | 909-11 W IRVING PARK BASEMENT | 901 W IRVING PARK RD | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCHES. UNVERIFIED DETECTORS AND CONDITIONS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | EAST - DOWNSPOUT - PAINT PEELING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR FENCE | FRONT GATE - OUT OF PLUMB AND LEANING AT SE CORNER | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPUTTY WINDOW PANES | EAST/1ST FLOOR - WINDOW TRIM - ROTTING NEAR NE CORNER | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PARAPET | SOUTH - PARAPET WALL - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CHIMNEY | WEST - CHIMNEY - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NORTH - #901 STOREFRONT - ADDRESS NOT POSTED | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | #901,#903, & #905 STOREFRONTS - FIRE EXTINGUISHERS - MISSING;#909 STOREFRONT - SERVICE TAG - MISSING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
WORK NOT ALLOWED | #901 & #903 STOREFRONTS - FIRE WALL BREACHED; NO PLANS SUBMITTED; NO PERMIT OBTAINED | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | #901 & #903 STOREFRONTS - SUBMIT PLANS AND OBTAIN PERMIT FOR ALL WORK RELATED TO AUTHORIZE BREACH OF FIRE WALL TO ANNEX TO COMMERCIAL UNITS INTO ONE OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | #903, #911, #905 STOREFRONTS/FRONT ENTRANCES - EXIT SIGNS - MISSING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH - KNEE WALL - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH - BRICK LEDGE (NEAR #905 STOREFRONT) - CRACKED | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - ADDRESS MISSING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR DOWNSPOUT | EAST - DOWNSPOUT - PAINT PEELING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR FENCE | FRONT GATE - OUT OF PLUMB AND LEANING AT SE CORNER | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPUTTY WINDOW PANES | EAST/1ST FLOOR - WINDOW TRIM - ROTTING NEAR NE CORNER | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PARAPET | SOUTH - PARAPET WALL - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH/BASEMENT - GLASS BLOCK WINDOWS - CRACKED PANES | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
WINDOW AREA ABOVE GROUND | SOUTH/BASEMENT - GLASS BLOCK WINDOWS - SOME FLUSH WITH GRADE | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CHIMNEY | WEST - CHIMNEY - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | NORTH - #901 STOREFRONT - ADDRESS NOT POSTED | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | #903, #911, #905 STOREFRONTS/FRONT ENTRANCES - EXIT SIGNS - MISSING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH - KNEE WALL - WASHED OUT MORTAR | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH - BRICK LEDGE (NEAR #905 STOREFRONT) - CRACKED | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CLASS B DOOR IN STAIRWELL | BUILDING / 901 THROUGH 911- 1ST FLOOR NON-RESIDENTIAL UNITS-REAR EXIT DOOR TO BASEMENT INTERIOR STAIRWAYS-MISSING CLASS B STAIRWELL DOORS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 911 REAR EXTERIOR PORCH / 3RD FLOOR RAILING PULLING AWAY FROM 6X6 COLUMN.STAIR TREAD FROM 2ND TO 3RD FLOOR-CRACKED. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR EXTERIOR PORCHES-FLOWER POTS SET ON GUARD RAILS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXTERIOR PORCHES-PERSONAL ITEMS STORED ON LANDINGS,(TABLE AND CHAIRS,COOLERS,COOKING GRILLS. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT BOILER ROOM-SMOKE DETECTOR,OUT OF SERVICE WITH LOW BATTERY. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM / CARBON MONOXIDE DETECTOR,OUT OF SERVICE WITH LOW BATTERY. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
CEMENT BASEMENT FLOOR | BASEMENT BOILER ROOM FLOOR-MISSING CONCRETE. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT LAUNDRY ROOM-MISSING SMOKE DETECTOR. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BUILDING THROUGHT-BASEMENT CEILINGS-MISSING 5/8 INCH DRYWALL.PERMIT REQUIRED. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | BUILDING / COURTYARD-JULIET RAILINGS-ONLY 30 INCHES IN HEIGHT,RUSTED.PERMIT REQUIRED. | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - ADDRESS MISSING | 901 W IRVING PARK RD | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | #901 STOREFRONT/FRONT ENTRY DOOR - EXIT SIGN - NOT WORKING AT TIME OF INSPECTION | 901 W IRVING PARK RD | PERIODIC | FAILED | View |