Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 2:31 AM
PIN: 17162030250000
Property Address: 50 S LA SALLE ST
City - Zip: CHICAGO - 60603
2023 Property Class: 591
2023 Township: 76 - South Chicago
2023 Neighborhood: 76010
2023 Tax District: 76058
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 42 Violations
Violation Inspector Comments Address Category Status View
POST APPROVED OCCUPANCY CARD REPLACE MISSING OCCUPANCY CARDS AT OAK STREET, BRONZEVILLE, LASALLE, LOGAN SQUARE, MEETING ROOMS 121 AND 125 THROUGH 128 50 S LA SALLE ST PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE MACHINE ROOM VENTILATION 50 S LA SALLE ST PERMIT PASSED View
INSTALL ROPE DATA TAG PASS IN REGARDS TO #5 AND #9. EV003690 50 S LA SALLE ST PERIODIC CLOSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CAB FLOORING 50 S LA SALLE ST PERMIT PASSED View
REPL/DEF COMP ROPES PASS IN REGARDS TO #1, AND #3. 50 S LA SALLE ST PERMIT FAILED View
OPEN TYPE VIOLATION 1. INSTALL FLUORESCENT LIGHTS IN "ALL" SECONDARY'S AND PITS. 2. STENCIL "ALL" EQUIPMENT IN MACHINE ROOM SECONDARY'S AND PITS. 18-30-010,13-20-120. 100063380 50 S LA SALLE ST PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TIGHTEN AND INSTALL LOCKWASHERS ON DIVIDER BEAM 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL RAIL STIFFENER ON #8 CAR RAIL 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL GFI'S IN PIT AND MACHINE ROOM 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE SELF CLOSER ON PIT AND MACHINE ROOM DOOR 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE MACHINE ROOM DOOR SIGNAGE ALSO FOR TRIP HAZARD 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA ADD STEP INSIDE PIT AT DOOR 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA STENCIL LABEL ALL EQUIPMENT, HOISTWAY DOORS 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CROSSHEAD DATA TAG 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CODE DATA PLATE ON CONTROLLER 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CARTOP HANDRAIL 50 S LA SALLE ST PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST FIRE RECALL AND SMOKES 50 S LA SALLE ST PERMIT PASSED View
ARRANGE COMPLETED PERMIT INSP. 50 S LA SALLE ST PERMIT PASSED View
POST APPROVED OCCUPANCY CARD OBTAIN NEW OCCUPANCY SIGNS FOR 3 LARGE SPACES AT NE CORNER OF 6TH FLR. 50 S LA SALLE ST PERIODIC FAILED View
POST APPROVED OCCUPANCY CARD 50 S LA SALLE ST PERIODIC FAILED View
ARRANGE FOR RE-INSPECTION OUT DOORA/C UNIT LOCATED INSIDE 50 S LA SALLE ST PERMIT FAILED View
ARRANGE FOR RE-INSPECTION CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM 50 S LA SALLE ST PERMIT PASSED View
POST APPROVED OCCUPANCY CARD OBTAIN NEW OCCUPANCY PLACARDS FOR 6TH FLOOR ASSEMBLEY HALL AND ANNEX (PREFUNCTION) 50 S LA SALLE ST PERIODIC FAILED View
REMOVE REMOVE FROM THE BOILER ROOM ANY EQUIPMENT THAT CONTAINS FREON. THIS PERTAINS TO ONE(1) CARRIER CONDENSING UNIT AND ONE (1) SANYO CONDENSING UNIT.THEY ARE PROHIBITED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THAT ROOM.(18-28-1104.3.4,18-28-1105.7) 50 S LA SALLE ST PERIODIC FAILED View
ARRANGE FOR RE-INSPECTION CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM 50 S LA SALLE ST PERIODIC FAILED View
REMOVE REMOVE FROM THE BOILER ROOM ANY EQUIPMENT THAT CONTAINS FREON. THIS PERTAINS TO ONE(1) CARRIER CONDENSING UNIT AND ONE (1) SANYO CONDENSING UNIT.THEY ARE PROHIBITED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THAT ROOM.(18-28-1104.3.4,18-28-1105.7) 50 S LA SALLE ST PERIODIC PASSED View
ARRANGE FOR RE-INSPECTION CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM 50 S LA SALLE ST PERIODIC PASSED View
REMOVE REMOVE ALL EQUIPMENT IN THE BOILER ROOM CONTAINING FREON.THIS PERTAINS TO ONE (1) CARRIER 4 TON CONDENSOR. FREON CONTAINING EQUIPMENT CANNOT BE INSTALLED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THIS ROOM. 50 S LA SALLE ST PERMIT PASSED View
ARRANGE FOR RE-INSPECTION CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM 50 S LA SALLE ST PERMIT PASSED View
REMOVE REMOVE ALL EQUIPMENT COTAINING FREON FROM THE BOILER ROOM.EQUIPMENT CONTAINING FREON CANNOT BE IN THE ROOM WHERE THE BOILERS DRAW THEIR COMBUSTION AIR. 50 S LA SALLE ST PERMIT PASSED View
ACCESS TO ROOF INSPECTION 50 S LA SALLE ST PERMIT FAILED View
ARRANGE FOR RE-INSPECTION INSPECTION 50 S LA SALLE ST PERMIT FAILED View
PRV RECEIVER FOR SIX REFRIGERATION SYSTEMS LOCATED ON 7TH FLR ROOF 50 S LA SALLE ST PERMIT FAILED View
POST APPROVED OCCUPANCY CARD POST OCCUPANCY CARD FOR LARGE ASSEMBLY ROOM ON 6TH FLR; SQUARE FOOTAGE IS 4810. 50 S LA SALLE ST PERIODIC PASSED View
OPEN TYPE VIOLATION 1. INSTALL A RAILING AROUND REAR OF CAR (TOP-ALL CARS). 2. PATCH "ALL" HOLES IN HOISTWAY MACHINE ROOM & SECONDARY 3. INSTALL A GUARD AROUND HOIST ROPES-CAR CWT. ALL CARS 4. INSTALL A STOP SWITCH IN SECONDARY (ALL CARS) 5. INSTALL A LIGHT SWITCH OUTSIDE OF SECONDARY DOOR 6. INSTALL A AUX. DISCONNECT IN LINE OF SIGHT (CARS #7,#8) 7. STENCIL PIT DOOR 2 FOOT DROP 8. STENCIL "ALL" EQUIPMENT 9. INSTALL CERTIFICATES INSIDE "ALL" ELEVATOR CABS 10. INSTALL ADDITIONAL LIGHTS IN ALL PITS 11. INSTALL G.F.I. OUTLETS IN M.R. SECONDARY AND PIT 12. REMOVE "ALL" OLD EQUIPMENT FROM M.R. AND SECONDARY AND PIT THAT IS NOT BEING USED 18-30-010,13-20-120. 50 S LA SALLE ST PERMIT FAILED View
POST APPROVED OCCUPANCY CARD REPLACE MISSING OCCUPANCY CARDS AT OAK STREET, BRONZEVILLE, LASALLE, LOGAN SQUARE, MEETING ROOMS 121 AND 125 THROUGH 128,125/126 COMBINED,6TH FLOOR GUEST T G ROOMS 50 S LA SALLE ST PERIODIC FAILED View
PROVIDE RELIEF OPENINGS NO EXH IN JA-CLOSET FINAL DENIED 50 S LA SALLE ST PERMIT FAILED View
OPEN TYPE VIOLATION PATCH ALL HOLES IN HOISTWAY AN M.R. (CAR 12). (18-30-010 AND 13-20-120) 100063380 50 S LA SALLE ST PERMIT FAILED View
OPEN TYPE VIOLATION ADD ADDITIONAL LIGHT IN PIT. (CAR 12) 50 S LA SALLE ST PERMIT FAILED View
REPL DEF HOIST ROPES PASS IN REGARDS TO #5 AND #9. 50 S LA SALLE ST PERIODIC CLOSED View
POST CURRENT CERTIF PASS ELE IN REGARDS TO "ALL". 50 S LA SALLE ST PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 50 S LA SALLE ST PERMIT PASSED View