The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST APPROVED OCCUPANCY CARD | REPLACE MISSING OCCUPANCY CARDS AT OAK STREET, BRONZEVILLE, LASALLE, LOGAN SQUARE, MEETING ROOMS 121 AND 125 THROUGH 128 | 50 S LA SALLE ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MACHINE ROOM VENTILATION | 50 S LA SALLE ST | PERMIT | PASSED | View |
INSTALL ROPE DATA TAG PASS | IN REGARDS TO #5 AND #9. EV003690 | 50 S LA SALLE ST | PERIODIC | CLOSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CAB FLOORING | 50 S LA SALLE ST | PERMIT | PASSED | View |
REPL/DEF COMP ROPES PASS | IN REGARDS TO #1, AND #3. | 50 S LA SALLE ST | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | 1. INSTALL FLUORESCENT LIGHTS IN "ALL" SECONDARY'S AND PITS. 2. STENCIL "ALL" EQUIPMENT IN MACHINE ROOM SECONDARY'S AND PITS. 18-30-010,13-20-120. 100063380 | 50 S LA SALLE ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | TIGHTEN AND INSTALL LOCKWASHERS ON DIVIDER BEAM | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL RAIL STIFFENER ON #8 CAR RAIL | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL GFI'S IN PIT AND MACHINE ROOM | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE SELF CLOSER ON PIT AND MACHINE ROOM DOOR | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE MACHINE ROOM DOOR SIGNAGE ALSO FOR TRIP HAZARD | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ADD STEP INSIDE PIT AT DOOR | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | STENCIL LABEL ALL EQUIPMENT, HOISTWAY DOORS | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CROSSHEAD DATA TAG | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CODE DATA PLATE ON CONTROLLER | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | INSTALL CARTOP HANDRAIL | 50 S LA SALLE ST | PERMIT | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | TEST FIRE RECALL AND SMOKES | 50 S LA SALLE ST | PERMIT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 50 S LA SALLE ST | PERMIT | PASSED | View | |
POST APPROVED OCCUPANCY CARD | OBTAIN NEW OCCUPANCY SIGNS FOR 3 LARGE SPACES AT NE CORNER OF 6TH FLR. | 50 S LA SALLE ST | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | 50 S LA SALLE ST | PERIODIC | FAILED | View | |
ARRANGE FOR RE-INSPECTION | OUT DOORA/C UNIT LOCATED INSIDE | 50 S LA SALLE ST | PERMIT | FAILED | View |
ARRANGE FOR RE-INSPECTION | CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM | 50 S LA SALLE ST | PERMIT | PASSED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN NEW OCCUPANCY PLACARDS FOR 6TH FLOOR ASSEMBLEY HALL AND ANNEX (PREFUNCTION) | 50 S LA SALLE ST | PERIODIC | FAILED | View |
REMOVE | REMOVE FROM THE BOILER ROOM ANY EQUIPMENT THAT CONTAINS FREON. THIS PERTAINS TO ONE(1) CARRIER CONDENSING UNIT AND ONE (1) SANYO CONDENSING UNIT.THEY ARE PROHIBITED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THAT ROOM.(18-28-1104.3.4,18-28-1105.7) | 50 S LA SALLE ST | PERIODIC | FAILED | View |
ARRANGE FOR RE-INSPECTION | CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM | 50 S LA SALLE ST | PERIODIC | FAILED | View |
REMOVE | REMOVE FROM THE BOILER ROOM ANY EQUIPMENT THAT CONTAINS FREON. THIS PERTAINS TO ONE(1) CARRIER CONDENSING UNIT AND ONE (1) SANYO CONDENSING UNIT.THEY ARE PROHIBITED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THAT ROOM.(18-28-1104.3.4,18-28-1105.7) | 50 S LA SALLE ST | PERIODIC | PASSED | View |
ARRANGE FOR RE-INSPECTION | CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM | 50 S LA SALLE ST | PERIODIC | PASSED | View |
REMOVE | REMOVE ALL EQUIPMENT IN THE BOILER ROOM CONTAINING FREON.THIS PERTAINS TO ONE (1) CARRIER 4 TON CONDENSOR. FREON CONTAINING EQUIPMENT CANNOT BE INSTALLED BECAUSE THE BOILERS DRAW THEIR COMBUSTION AIR FROM THIS ROOM. | 50 S LA SALLE ST | PERMIT | PASSED | View |
ARRANGE FOR RE-INSPECTION | CALL INSPECTOR MARK HOUTSMA (312)743-3562 MONDAYS BETWEEN 8:00-9:00 AM | 50 S LA SALLE ST | PERMIT | PASSED | View |
REMOVE | REMOVE ALL EQUIPMENT COTAINING FREON FROM THE BOILER ROOM.EQUIPMENT CONTAINING FREON CANNOT BE IN THE ROOM WHERE THE BOILERS DRAW THEIR COMBUSTION AIR. | 50 S LA SALLE ST | PERMIT | PASSED | View |
ACCESS TO ROOF | INSPECTION | 50 S LA SALLE ST | PERMIT | FAILED | View |
ARRANGE FOR RE-INSPECTION | INSPECTION | 50 S LA SALLE ST | PERMIT | FAILED | View |
PRV RECEIVER | FOR SIX REFRIGERATION SYSTEMS LOCATED ON 7TH FLR ROOF | 50 S LA SALLE ST | PERMIT | FAILED | View |
POST APPROVED OCCUPANCY CARD | POST OCCUPANCY CARD FOR LARGE ASSEMBLY ROOM ON 6TH FLR; SQUARE FOOTAGE IS 4810. | 50 S LA SALLE ST | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | 1. INSTALL A RAILING AROUND REAR OF CAR (TOP-ALL CARS). 2. PATCH "ALL" HOLES IN HOISTWAY MACHINE ROOM & SECONDARY 3. INSTALL A GUARD AROUND HOIST ROPES-CAR CWT. ALL CARS 4. INSTALL A STOP SWITCH IN SECONDARY (ALL CARS) 5. INSTALL A LIGHT SWITCH OUTSIDE OF SECONDARY DOOR 6. INSTALL A AUX. DISCONNECT IN LINE OF SIGHT (CARS #7,#8) 7. STENCIL PIT DOOR 2 FOOT DROP 8. STENCIL "ALL" EQUIPMENT 9. INSTALL CERTIFICATES INSIDE "ALL" ELEVATOR CABS 10. INSTALL ADDITIONAL LIGHTS IN ALL PITS 11. INSTALL G.F.I. OUTLETS IN M.R. SECONDARY AND PIT 12. REMOVE "ALL" OLD EQUIPMENT FROM M.R. AND SECONDARY AND PIT THAT IS NOT BEING USED 18-30-010,13-20-120. | 50 S LA SALLE ST | PERMIT | FAILED | View |
POST APPROVED OCCUPANCY CARD | REPLACE MISSING OCCUPANCY CARDS AT OAK STREET, BRONZEVILLE, LASALLE, LOGAN SQUARE, MEETING ROOMS 121 AND 125 THROUGH 128,125/126 COMBINED,6TH FLOOR GUEST T G ROOMS | 50 S LA SALLE ST | PERIODIC | FAILED | View |
PROVIDE RELIEF OPENINGS | NO EXH IN JA-CLOSET FINAL DENIED | 50 S LA SALLE ST | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | PATCH ALL HOLES IN HOISTWAY AN M.R. (CAR 12). (18-30-010 AND 13-20-120) 100063380 | 50 S LA SALLE ST | PERMIT | FAILED | View |
OPEN TYPE VIOLATION | ADD ADDITIONAL LIGHT IN PIT. (CAR 12) | 50 S LA SALLE ST | PERMIT | FAILED | View |
REPL DEF HOIST ROPES PASS | IN REGARDS TO #5 AND #9. | 50 S LA SALLE ST | PERIODIC | CLOSED | View |
POST CURRENT CERTIF PASS ELE | IN REGARDS TO "ALL". | 50 S LA SALLE ST | PERMIT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 50 S LA SALLE ST | PERMIT | PASSED | View |