Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS 2ND FLOOR APARTMENT; INTERIOR STAIRWELL - SMOKE DETECTOR - MISSING 7359 N SEELEY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 2ND FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING 7359 N SEELEY AVE COMPLAINT FAILED View
INSECTS 2ND FLOOR APARTMENT - INSECTS IN BEDROOM 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 BEAMS NOTCHED, TOENAILED TO 6X6 COLUMNS; UNDERSIZED 4X4 COLUMNS; 2X8 JOISTS SPAN 9'-2"; SPLICE JOINTS AT 4X4 COLUMN ONLY 4"-8" WITH ONLY ONE BOLT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. 7359 N SEELEY AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT MOST APARTMENTS AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 7359 N SEELEY AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 3RD FLOOR APARTMENT- NO HEAT. 59 DEGREES DINING ROOM, 58 DEGREES LIVING ROOM, 55 DEGREES FRONT BED ROOM. 7359 N SEELEY AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS THIRD FLOOR APARTMENT- FURNACE NOT IN SERVICE, NOT OPERATING. ELECTRICITY NOT FUNCTIONING TO HEATING UNIT (ELECTRICITY NOT OPERATING FRONT OF APARTMENT IN LIVING ROOM, FURNACE CLOSET, FRONT BEDROOM). 7359 N SEELEY AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE FRONT BED ROOM WINDOW NOT CLOSING, SASH WILL NOT COME DOWN. 7359 N SEELEY AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING- NO OWNER'S ID SIGN POSTED. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR WOODEN THREE STORY PORCH,COLUMNS ONLY HAVE 12 IN. SPLICE,AND TWO BOLTS.4X4 COLUMNS USED ON STAIR STRINGERS GRADE THRU THIRD FLOOR.VERTICAL 6X6 BEAMS TO COLUMNS NOT STRAPPED TOGETHER,ONLY NAILED TOGETHER. 7359 N SEELEY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT APT. MISSING CARBON MONOXIDE DETECTOR. 7359 N SEELEY AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT AND PLANS. 7359 N SEELEY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN A PERMIT TO AUTHORIZED ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO ORIGIONAL STATE. 7359 N SEELEY AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- THIRD FLOOR APT. NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL BOWING BRICK, SHIFTING BRICK AND FRACTURES OFF OF LINTELS- MOST NOTABLE AT 3. 7359 N SEELEY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT ILLEGAL CONVERSION. APARTMENT CONSTRUCTED- KITCHEN, BEDROOM, BATHROOM, LIVINGROOM, PARTITIONS. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE (PEMIT AND PLAN REQUIRED FOR DECONVERSION). 7359 N SEELEY AVE COMPLAINT FAILED View
HEATING PLANT SEPARATION BASEMENT- BOILER/ FURNACE AND HOT WATER HEATER ROOM- PIPE, DUCT AND VARIOUS PENETRATIONS THROUGHOUT. CEILING CONSTRUCTED OF FIBER BOARD- NO FIRE RATING. NO DOOR ON HEATING PLANT ROOM. BASEMENT ILLEGAL APARTMENT ALSO HAS FURNACE IN FRONT CLOSET SERVING 1RST FLOOR APARTMENT- FOLDING CLOSET DOORS, NO FIRE RATING. 7359 N SEELEY AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT BASEMENT ILLEGAL APARTMENT BATHROOM WITH WATER DAMAGE/ STAINS, LOOSE JOINT COMPOUND AND TAPE. FRONT LOBBY CEILING WITH FRACTURES AND WATER DAMAGE. 7359 N SEELEY AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 1RST FLOOR APARTMENT REAR BATHROOM- CLOGGED TOILET. 7359 N SEELEY AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS APARTMENT 3- LIVING ROOM AND FRONT BEDROOM OUTLETS NOT IN SERVICE. 7359 N SEELEY AVE COMPLAINT FAILED View
WORK NOT ALLOWED APARTMENTS AT 1 AND 3- PARTIONS ERECTED IN LIVING ROOM, CREATING ADDITIONAL BEDROOM. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ELECTRIC) INSTALLED WITH OUT A PERMIT. 7359 N SEELEY AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST I.D. 7359 N SEELEY AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE BASEMENT ILLEGAL APARTMENT- SPACE HEATERS AND STOVE TOP/ OVEN USED FOR HEAT. NO PERMANENT HEATING SYSTEM INSTALLED TO SERVE BASEMENT APARTMENT. 7359 N SEELEY AVE COMPLAINT FAILED View
SUPPORT FIXTURES INTERIOR STAIRWELL - 2ND FLOOR - LOOSE WALL FIXTURE; UNSECURED. 7359 N SEELEY AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR PORCH - BBQ GRILLS ON 2ND, 3RD FLOOR DECKS. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR SCREENS REPAIR REPLACE DEFECTIVE SCREENS THROUGHOUT. 7359 N SEELEY AVE COMPLAINT FAILED View
ROACHES BASEMENT, 1RST AND 3RD FLOORS- ROACH INFESTATION. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3 STORY PORCH- COLUMNS ON SLAB. LOOKOUT BEAM AND COLUMN CONNECTIONS FASTENED/ ANCHORED WITH NAILS ONLY. COLUMNS OVER CUT AT FIRE CUTS- MORE THAN 2''. LOOKOUT BEAMS SPAN 8' 8''. RIM JOISTS ANCHORED WITH NAILS ONLY. RAILS ANCHORED WITH NAILS AND/ OR SCREWS ONLY. STRINGERS AT SOME LOCATIONS ANCHORED WITH NAILS ONLY. SOME JOISTS ANCHORED WITH NAILS ONLY. LANDING JOISTS OVER HAND LANDING BEAM BY 3 1/2''. RISER HEIGHTS VARY - 6 1/2'', 8'', 1 1/2'', 7'', 8 1/2''. LOOSE DECKING. 4X4 COLUMNS WITH 1/2 LAPP JOINT SPLICES AS LITTLE AS 4'' AND FASTENED WITH 1 BOLT. OUT OF PLUMB, BOWED AND WARPED OVER EXTENDED 4X4 COLUMNS. CRACKED/ SPLIT TREADS. OBTAIN PLAN AND PERMIT. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR LINTELS WEST ELEVATION LINTELS SIGNIFICANT SAGGING, RUST BLEADING THROUGH PAINT. NORTH AND SOUTH ELEVATIONS AT WEST ENDS- LINTELS SAGGING AND RUSTING. NORTH ELEVATION AT 3 LARGE LINTEL RUSTING AND SAGGING. OBTAIN PERMIT. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3 STORY PORCH- COLUMNS ON SLAB. LOOKOUT BEAM AND COLUMN CONNECTIONS FASTENED/ ANCHORED WITH NAILS ONLY. COLUMNS OVER CUT AT FIRE CUTS- MORE THAN 2''. LOOKOUT BEAMS SPAN 8' 8''. RIM JOISTS ANCHORED WITH NAILS ONLY. RAILS ANCHORED WITH NAILS AND/ OR SCREWS ONLY. STRINGERS AT SOME LOCATIONS ANCHORED WITH NAILS ONLY. SOME JOISTS ANCHORED WITH NAILS ONLY. LANDING JOISTS OVER HAND LANDING BEAM BY 3 1/2''. RISER HEIGHTS VARY - 6 1/2'', 8'', 1 1/2'', 7'', 8 1/2''. LOOSE DECKING. 4X4 COLUMNS WITH 1/2 LAPP JOINT SPLICES AS LITTLE AS 4'' AND FASTENED WITH 1 BOLT. OUT OF PLUMB, BOWED AND WARPED OVER EXTENDED 4X4 COLUMNS. CRACKED/ SPLIT TREADS. OBTAIN PLAN AND PERMIT. 7359 N SEELEY AVE COMPLAINT FAILED View
DEMO DEBRIS GARAGE- FILLED WITH DEMO DEBRIS, DRYWALL, WOOD, GARBAGE, MATRESSES. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE- SPALLING BRICK AND ERODING MORTAR VARIOUS LOCATIONS THROUGHOUT. 7359 N SEELEY AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE BASEMENT ILLEGAL APARTMENT BEDROOM WINDOW- LOOSE IN TRACK, AIR INFILTRATION, FRACTURED AND LOOSE TRIM. 7359 N SEELEY AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BASEMENT - SMOKE DETECTOR NOT IN SERVICE. 7359 N SEELEY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID NO CARBON MONOXIDE DETECTOR- BASEMENT. 7359 N SEELEY AVE COMPLAINT FAILED View