Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR INSPECTION | CONTACT INSPECTOR PULLEN #651 312-617-6321. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
ACCESS TO ROOF | 3049 N CICERO AVE | PERIODIC | FAILED | View | |
REPAIR WINDOW SILLS | FRONT OPEN SILLS | 3049 N CICERO AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR 2ND FLOOR GUARDRAIL TOO LOW. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | FULL ACCESS NEEDED TO BUILDING AND PORCH. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF REAR PORCH ISSUES. GATES LOCKED, NO ACCESS. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS - WASHED OUT MORTAR. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S / MANAGEMENT SIGN POSTED. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | SKYLIGHT - BROKEN GLASS PANES COVERED WITH ROOFING MATERIAL. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | MISSING PEEPHOLES. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
REPAIR ROOF | ROOF LEAKING INTO FURNACE ROOMS IN APARTMENTS 2 AND 3. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
EXPOSED WIRING | 2ND FLOOR BATHROOM - EXPOSED WIRES. | 3049 N CICERO AVE | PERIODIC | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | 1 BLDG MOUNTED 18'X 3' SIGN READS: "ESTRELLA BLANCA NIGHT CLUB" (WEST ELEVATION) 13-20-520 | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH & SOUTH ELEVATIONS - DEEPLY SPALLED, DETERIORATING, LOOSE BRICK, STEP/STRESS FRACTURES & EXTREME WASHED OUT MORTAR IN VARIOUS LOCATIONS THRU-OUT. 14X-3-303.6, 14X-3-305.1.1 PERMITS REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ELEVATION - 3RD FLR. LINTEL - RUSTING THROUGH, BENT, DEFLECTING & SAGGING WITH GAPS. 14X-3-303.1.1, 14X-3-303.4PLANS AND PERMITS REQUIRED TO BE REPLACED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | DAMAGED LIGHT FIXTURES, CORRODED LIGHT FIXTURES, MISSING GLOBES BASEMENT AND 1ST FLOOR. REPLACE WHERE REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS ARE REQUIRED FOR CHANGE OF USE FROM MERCANTILE TO A2 USE. ALL WORK IS SUBJECT TO FIELD INSPECTION AND APPROVAL. (SEC 14A-4-404.1)LICENSE LIMITED TO 99, THERE WAS 130 OCCUPANTS IN THE BAR WITH NO PPAL AND LIVE BAND. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR KITCHEN - PUDDLES OF WATER WITH LEAKING PIPES. UNSANITARY CONDITIONS.(SEC 14X-3-307) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR - LOOSE / MISSING DROP CEILING TILES AND HOLES AT EXPOSED PLASTER AREAS.(SEC 14X-3-307) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR - LOOSE , ROTTED AND DELAMINATED FLOORING . TRIP HAZARD. (14X-3-303.4) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | REAR ELEVATION - MISSING DOWNSPOUT CONNECTION TO SEWER.(14X-3-303.7) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION - FRACTURES, LOOSE AND ERDOED MORTAR AT VARIOS LOCATIONS.(14X-3-303.7) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR INTERIOR AND EXTERIOR MEANS OF EGRESS - DOR SLIDE BOLTED WITH STORAGE OBSTRUCTING EGRESS. DANGEROUS AND HAZARDOUS. (SEC 14X-5-505.1.2) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | TOTAL LACK OF FIRE SEPARATION ON BASEMENT CEILING. 1HR REQUIRED. 5/8" FIRECODE TYPE "X" | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | DAMAGED WIRING VISIBLE AT OPEN BOXES AND PANELS IN BASEMENT. REPLACE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | UNSUPPORTED BOXES VARIOUS AREAS BASEMENT. SECURE WHERE REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | SEVERELY CORRODED EQUIPMENT VARIOUS AREAS BASEMENT. REMOVE WHERE REQUIRED THROUGHOUT. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | NO VISIBLE WATER GROUND. ENSURE SERVICE GROUNDED IN APPROVED MANNER. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PROVIDE | MISSING MIXING VALVE AT LAVATORIES. (18-29-607) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES AT 1ST FLOOR AND WHERE REQUIRED TO ELIMINATE THE USE OF EXTENSION CORDS AND CORDS THROUGH CEILINGS. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | EXTENSION CORDS SUPPLYING PERMANENT APPLIANCES 1ST FLOOR. EQUIPMENT CORDS THROUGH CEILING 1ST FLOOR. UNAPPROVED CORDS SUPPLYING EXIT SIGN 1ST FLOOR. REMOVE UNAPPROVED CORDS WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PROVIDE FULL ACCESS FOR DROP CEILING INSPECTION AT 1ST FLOOR AND WHERE REQUIRED. (14A-5-505.2) | 3049 N CICERO AVE | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROVIDE ONE LINE DIAGRAM AND LOAD CALCULATION FOR ELECTRICAL SERVICE AND FEEDERS. (14E-2-215.5, 14E-2-220.40) | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION EXTERIOR ENTRIES, INTERIOR AND EXTERIOR STAIRS, BASEMENT AREAS. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | SEVERAL JOISTS BELOW MENS AND WOMANS BATHROOM ARE ROTTED AND OR INCORRECTLY REPAIRED. NEWER JOISTS ROUGHLY 6FT IN LENGTH WERE SISTERED TO EXISTING ROTTED JOISTS THATY DOES NOT SIT IN POCKET AND DOES NOT SPAN TO MAIN CENTER BEAM. PROVIDE PERMIT TO REPLACE IN KIND. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI PROTECTION KITCHEN, BATH, SINKS, BASEMENT, EXTERIOR, WET LOCATIONS. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | ALL EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATIONS. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | UNAPPROVED ROUND BOWL TOILET WITH CLOSED FRONT SEAT. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN BOXES VARIOUS AREAS BASEMENT. CLOSE WHERE REQUIRED THROUGHOUT. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | UNAPPROVED PVC DRAINAGE PIPING AND SADDLE HUBS THROUGHOUT. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | EMERGENCY LIGHTING SYSTEM AT 1ST FLOOR AND BASEMENT IS INSUFFICIENT, UNAPPROVED, UNMAINTAINED, UNABLE TO TEST. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | TOILETS MISSING VENTS OBSERVED IN BASEMENT CEILING. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT VIOLATIONS. (14A-4-404.6) | 3049 N CICERO AVE | COMPLAINT | FAILED | View | |
ABANDONED EQUIPMENT | ABANDONED SERVICE RISER REAR EXTERIOR. ABANDONED EQUIPMENT THROUGHOUT BASEMENT. REMOVE WHERE REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | SUMP PIT AT BASEMENT MISSING LID. CURRENTLY HAS PLYWOOD LID. DANGEROUS AND HAZARDOUS. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | DETERIORATED SERVICE CABLES. DETERIORATED SERVICE RACEWAYS. DETERIOATED DISCONNECTS, METERING AND DISTRIBUTION. SERVICE(S) MODIFIED FROM ORIGINGAL CONDITION. ENSURE SERVICE IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | 3049 N CICERO AVE | COMPLAINT | FAILED | View | |
PERMIT REQUIRED - CONTRACTOR | PROVIDE PERMIT FOR STRUCTURAL AND INSTALLATION OF DRYWALL AT BASEMENT | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BEEPING SMOKE DETECTOR AT BASMENT AREA. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | RACEWAYS NOT CONNECTED TO BOXES BASEMENT AND 1ST FLOOR FRONT. ENSURE GROUND CONTINUITY WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | OPEN WIRING 1ST FLOOR FRONT EXIT SIGN. OPEN WIRING BASEMENT. REMOVE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | UNSUPPORTED RACEWAYS VARIOUS AREAS BASEMENT. SECURE WHERE REQUIRED | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DETERIORATED BROKEN RECEPTACLES AND SWITCHES 1ST FLOOR AND BASEMENT. REPLACE WHERE REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | 3049 N CICERO AVE | COMPLAINT | FAILED | View | |
DEFECTIVE DISTRIBUTION | OPEN, DAMAGED, TAMPERED PANELS BASEMENT AREA. UNAPPROVED TAPS INCLUDING DOUBLE LUGGING MULTIPLE CABLES TERMINATED UNDER SINGLE LUGS. ENSURE DISTRIBUTION THROUGHOUT PREMISES IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | MISSING DIE-ELECTRICAL UNIONS AT WATER HEATER. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | 3 STORY MASONRY BUILDING.WEST ELEVATION - EXTREME WASHED OUT MORTAR IN VARIOUS LOCATIONS THRU-OUT. 14X-3-303.1.1, 14X-3-302.2, 14X-3-303.6, 14X-3-305.1.1 PROVIDE HEAVY DUTY SCAFFOLDING WITH CANOPY ON WEST ELEVATION DURING REPAIRS.PERMITS REQUIRED. | 3049 N CICERO AVE | COMPLAINT | FAILED | View |