Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | SOUTH ELEVATION AT 3RD FLOOR -LARGE FRACTURE , NORTH ELEVATION- IRON JOINTS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS MISSING &TORN SCREENS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH AT 7842 4X4 COLUMNS MISSING BOLTS ON LEDGERS ,COLUMNS AND BEAMS RAIL ABOVE 42" THRU GRADE TO 3RD . | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | FRONT INTERIOR DOORS - IRON GATES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2218 E 79TH ST | COMPLAINT | FAILED | View | |
HEAT UNIT ADEQUATELY | 2218 E 79TH ST | COMPLAINT | FAILED | View | |
REPAIR ROOF | REAR ELEVATION, 2218-26 AND 7842-48: ROOF HATCHES OPEN | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION, 7848-48: OPEN MORTAR JOINTS; SOUTH ELEVATION, 3RD LEVEL: SHIFTING MASONRY, OPEN MORTAR JOINTS AT ORNAMENTAL PROJECTIONS | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR ELEVATION AND EAST ELEVATION, BASEMENT: WINDOW PANES BROKEN; 2226, EAST ELEVATION, STORE FRONT: WINDOW PANE BROKEN | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 2218-269, REAR WOOD PORCH: IMPROPER BLOCK FOUNDATIONS CRACKED AND MISSING SECTIONS, JOISTS MISSING HANGERS, BEAM-COLUMN CONNECTIONS MISSING BOLTS AND STEEL ANGLES, COLUMN 1/2 LAP JOINTS MISSING BOLTS, SHIMS AT COLUMNS SUPPORTING ROOF, LEVEL 2 AND 3-BEAM SUPPORTING JOISTS AT MIDSPAN NOTCHED AND FRAMED AROUND LINTEL AT DOOR, GUARD RAILS AND HADN RAILS MISSING ANGLE CONNECTION, 3RD LEVEL GUARD RAIL SOUTH-BROKEN PICKET; 7842-48, REAR WOOD PORCH: IMPROPER CONCRETE BLOCK FOUNDATION, JOISTS MISSINGHANGERS, BEAM-COLUMN CONNECTIONS MISSING BOLTS AND STEEL ANGLES, 1/2 LAP JOINTS MISSING BOLTS, SHIMS AT COLUMNS SUPPORTING ROOF, 2ND LEVEL NORTH GUARD RAIL BROKEN PICKET, STRINGERS MISSING BOLTS AT MASONRY WALLS, GUARD RAILS AND HAND RAILS MISSING ANGLE CONNECTORS | 2218 E 79TH ST | PERIODIC | FAILED | View |
MICE/RODENTS | EAST ELEVATION, SOUTH CORNER: 1'X1' HOLE AT GRADE LEVEL, RODENTS ENTERING AT TIME OF INSPECTION | 2218 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND COMPLAINT OF SR#100977143 ALSO REAR PORCHES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO CHECK OCCUPANCY,DETECTORS AND COMPLAINT OF SR#100977143 ALSO REAR PORCHES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 2218-22 BUILDING ENTRY DOOR, BROKEN LOCK.7842-44 ENTRY DOOR BROKEN KNOB. REAR DOOR 2222 BROKEN PANEL. | 2218 E 79TH ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATES PADLOCKED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
INSTALL DEAD BOLT LOCK | BUILDING ENTRY DOORS MISSING DEADBOLT LOCKSET. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 7842-44 FOYER DOOR BROKEN LITE. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR SCREENS | SOUTH AND EAST ELEVATIONS, 2ND AND 3RD FLOORS, TORN AND MISSING SCREENS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 7842-44 ENTRY FOYER, INTERIOR STAIRWELLS BROKEN PLASTER PEELING PAINT. | 2218 E 79TH ST | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | INTERIOR STAIRWELLS 7842 AND 2218 TRASH, AND DISCARDED ITEMS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
SCAVENGER SERVICE | REAR YARD GARBAGE OVERFLOWING CITY GARBAGE CANS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | INTERIOR CORRIDORS 2ND AND 3RD FLOORS MISSING FIRE EXTINGUISHERS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | 2226-NON RESIDENT UNIT FRONT DOOR/DOUBLE KEYED LOCK | 2218 E 79TH ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATES PADLOCKED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 2218-22 BUILDING ENTRY DOOR, BROKEN LOCK.7842-44 ENTRY DOOR BROKEN KNOB. REAR DOOR 2222 BROKEN PANEL. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR DOOR, INT. | 7842-44 FOYER DOOR BROKEN LITE. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR SCREENS | SOUTH AND EAST ELEVATIONS, 2ND AND 3RD FLOORS, TORN AND MISSING SCREENS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 7842-44 ENTRY FOYER, INTERIOR STAIRWELLS BROKEN PLASTER PEELING PAINT. | 2218 E 79TH ST | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | INTERIOR STAIRWELLS 7842 AND 2218 TRASH, AND DISCARDED ITEMS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
SCAVENGER SERVICE | REAR YARD GARBAGE OVERFLOWING CITY GARBAGE CANS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | INTERIOR CORRIDORS 2ND AND 3RD FLOORS MISSING FIRE EXTINGUISHERS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
EXPOSED WIRING | INTERIOR STAIRWELL EMERGENCY LIGHTING SYSTEM EXPOSED WIRES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | 7842-2218 REAR EXTERIOR CONCRETE STAIRS GRADE TO BASEMENT CRACK TREADS-MISSING HANDRAILS | 2218 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | 2218-REAR EXTERIOR STAIRS GRADE TO BASEMENT GUARDRAIL RUSTED | 2218 E 79TH ST | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR EXTERIOR STAIRS GRADE TO BASEMENT-JUNK AND REFUSE ACCUMULATING ALSO 7842 3RD FLOOR REAR PORCH | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR ROOF | 2226-REAR PORCH ROOF CENTER BEAM NOT SUPPORTING END ROOF RAFTER | 2218 E 79TH ST | COMPLAINT | PASSED | View |
NOTIFY DOB, USE OF VACANT LND | 2218-2226-2ND FLOOR UNITS VACANT AND OPEN | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | 2218-2226 2ND FLOOR UNITS WALLS WITH HOLES MISSING DRYWALL | 2218 E 79TH ST | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2226-1ST FLOOR NON-RESIDENT UNIT-NO HOT WATER | 2218 E 79TH ST | COMPLAINT | PASSED | View |
PROVIDE HOT WATER TO FIXTURES | 2226-1ST FLOOR NON-RESIDENT UNIT NO COLD WATER | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | 2 REAR EXTERIOR PORCHES-WITH THE SAME DEFECTS 4X4 AND 6X6 COLUMNS SET ON SIDE WALK AND CRACKED CONCRETE BLOCKS FOUNDATION STATUS UNKNOWN-JOISTS ARE FACE NAILED ONLY-RIM JOISTS FACE NAILED ONLY BEAM TOE NAILED | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | ONLY-2X8 BEAMS NOT ATTACHED TO WALL-4X4 BEAMS NOTCHED BEAM AND COLUMN CONNECTION STACKED COLUMN 4X4-4X6-6X6 HALF-LAP JOINTS NAILED ONLY RAILS ARE LOOSE AND PULLING MASONRY NAILED TO WORK TOE NAILED TO SUPPORTS-STAIR STRINGERS FACE NAILED AT TOP CONNECTION TREADS SPLITTING-STRINGERS SALE MASONRY NAILED TO WALL-DECKING BOARDS ARE SPLITTING WITH NAILS POPPING PLANS AND PERMIT REQUIRED FOR REPAIR OR REPLACEMENT | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2224-NOW RESIDENT UNIT-FRONT WINDOW BROKEN PANES | 2218 E 79TH ST | COMPLAINT | PASSED | View |
UNSANITARY CONDITIONS-ANIMALS | 7848-REAR PORCH 3RD FLOOR-DOG FECES | 2218 E 79TH ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | TWO PORCHES. 1ST PORCH ... (7842-44) ... 3 STORY WOOD, OPEN FRAME PORCH ... THE 6"X6" STRUCTURAL COLUMN SECTIONS (SUPPORTING THE PORCH DECKS) ARE IMPROPERLY FASTENED TO ONE ANOTHER. THEY HAVE BEEN STACKED ATOP ONE ANOTHER WITH NO FASTENERS WHAT SO EVER. ALSO, THESE 6"X6" COLUMNS ARE SEVERELY OVER NOTCHED (DOUBLE RIM JOIST CONECTIONS); THIS HAS REDUCED THE COLUMNS' ORIGINAL DIMENSION FROM 6"X6" TO 6"X2". THESE COLUMN SECTIONS HAVE REDUCED STRUCTURAL INTEGRITY DUE TO THIS IMPROPER OVER NOTCHING. ALSO, THE COLUMNS SUPPORTING THE STAIR FLIGHTS AND STAIR LANDINGS ARE UNDERSIZED 4"X4" BOARDS. ALL STRUCTURAL CONECTIONS ASSOCIATED WITH THESE COLUMNS ARE NAIL JOINTED ... THERE ARE NO BOLTED CONECTIONS OR STRUCTURAL SUPPORT BRACKETS. THE STAIR AND PORCH BANISTERS ARE TOO LOW (38"). THERE ARE NO METEAL TIE BACK CLIPS TO FASTEN THE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POSTS FOR THESE BANISTERS ARE NAILED, NOT BOLTED. THE SATIR FLIGHTS ARE 14 STEP SECTIONS FROM TOP TO BOTTOM WITHOUT AN IMTERMEDIATE LANDING. THERE ARE ALSO SUBSTAINDARD (UNDERSIZED) BEAMS SUPPOORTING THE PORCH DECKS (SINGLE 2"X8" BOARDS).THIS PORCH IS BEYOND UPGRADE STATUS ... INCORRECTLY BUILT AND IN VERY POOR CONDITION ... RECOMMEND TEASR DOWN AND REPLAC E WITH NEW. PLANS AND PERMIT ARE REQUIRED.2CD PORCH ... (2218-2226). 3 STORY OPEN WOOD FRAME PORCH. ALL FOOTINGS FOR THE STRUCTURAL COLUMNS ARE OF AN UNDERMINED DEPTH. THE 6"X6" COLUMN / BEAM JOINTS ARE (OVER) NOTCH JOINTED. THESE JOINTS ARE PULLING APART. THERE ARE NO STRUCTURAL BRACKETS AT THESE VITAL JOINTS FOR SUPPORT AND CONECTION. THERE ARE ALSO 2 TYPES OF UNDERSIZED COLUMNS BEING USED FOR STRUCTURAL SUPPORT (4"X6" AND 4"X4"). THE BANISTER SECTIONS ARE TOO LOW (38"). THERE ARE NO METAL TIE BACK CLIPS TO CONECT THESE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POST ARE NAIL, NOT BOLT FASTENED. THE STAIR FLIGHTS ARE 14 STEP RUNS WITHOUT ANY INTERMEDIATE LANDINGS. THIS PORCH IS NOT UP TO MINIMUM CODE ... TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT ARE REQUIRED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
SCAVENGER SERVICE | REAR YARD GARBAGE OVERFLOWING CITY GARBAGE CANS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | INTERIOR CORRIDORS 2ND AND 3RD FLOORS MISSING FIRE EXTINGUISHERS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | TWO PORCHES. 1ST PORCH ... (7842-44) ... 3 STORY WOOD, OPEN FRAME PORCH ... THE 6"X6" STRUCTURAL COLUMN SECTIONS (SUPPORTING THE PORCH DECKS) ARE IMPROPERLY FASTENED TO ONE ANOTHER. THEY HAVE BEEN STACKED ATOP ONE ANOTHER WITH NO FASTENERS WHAT SO EVER. ALSO, THESE 6"X6" COLUMNS ARE SEVERELY OVER NOTCHED (DOUBLE RIM JOIST CONECTIONS); THIS HAS REDUCED THE COLUMNS' ORIGINAL DIMENSION FROM 6"X6" TO 6"X2". THESE COLUMN SECTIONS HAVE REDUCED STRUCTURAL INTEGRITY DUE TO THIS IMPROPER OVER NOTCHING. ALSO, THE COLUMNS SUPPORTING THE STAIR FLIGHTS AND STAIR LANDINGS ARE UNDERSIZED 4"X4" BOARDS. ALL STRUCTURAL CONECTIONS ASSOCIATED WITH THESE COLUMNS ARE NAIL JOINTED ... THERE ARE NO BOLTED CONECTIONS OR STRUCTURAL SUPPORT BRACKETS. THE STAIR AND PORCH BANISTERS ARE TOO LOW (38"). THERE ARE NO METEAL TIE BACK CLIPS TO FASTEN THE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POSTS FOR THESE BANISTERS ARE NAILED, NOT BOLTED. THE SATIR FLIGHTS ARE 14 STEP SECTIONS FROM TOP TO BOTTOM WITHOUT AN IMTERMEDIATE LANDING. THERE ARE ALSO SUBSTAINDARD (UNDERSIZED) BEAMS SUPPOORTING THE PORCH DECKS (SINGLE 2"X8" BOARDS).THIS PORCH IS BEYOND UPGRADE STATUS ... INCORRECTLY BUILT AND IN VERY POOR CONDITION ... RECOMMEND TEASR DOWN AND REPLAC E WITH NEW. PLANS AND PERMIT ARE REQUIRED.2CD PORCH ... (2218-2226). 3 STORY OPEN WOOD FRAME PORCH. ALL FOOTINGS FOR THE STRUCTURAL COLUMNS ARE OF AN UNDERMINED DEPTH. THE 6"X6" COLUMN / BEAM JOINTS ARE (OVER) NOTCH JOINTED. THESE JOINTS ARE PULLING APART. THERE ARE NO STRUCTURAL BRACKETS AT THESE VITAL JOINTS FOR SUPPORT AND CONECTION. THERE ARE ALSO 2 TYPES OF UNDERSIZED COLUMNS BEING USED FOR STRUCTURAL SUPPORT (4"X6" AND 4"X4"). THE BANISTER SECTIONS ARE TOO LOW (38"). THERE ARE NO METAL TIE BACK CLIPS TO CONECT THESE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POST ARE NAIL, NOT BOLT FASTENED. THE STAIR FLIGHTS ARE 14 STEP RUNS WITHOUT ANY INTERMEDIATE LANDINGS. THIS PORCH IS NOT UP TO MINIMUM CODE ... TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT ARE REQUIRED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
EXPOSED WIRING | INTERIOR STAIRWELL EMERGENCY LIGHTING SYSTEM EXPOSED WIRES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT COMPLETE. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION CORNICE OPEN MORTAR JOINT. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION 1ST FLOOR SPRAWING BRICK AND WASHED OUT MORTAR | 2218 E 79TH ST | PERIODIC | FAILED | View |
SCAVENGER SERVICE | REAR YARD GARBAGE OVERFLOWING CITY GARBAGE CANS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING ¿ NO RESPONSE TO CHECK DETECTOR AND CONDITIONS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
ROACHES | REAR PORCH AT 7842 4X4 COLUMNS MISSING BOLTS ON INTERIOR APTS -ROACHES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
EXPOSED WIRING | INTERIOR STAIRWELL EMERGENCY LIGHTING SYSTEM EXPOSED WIRES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | TWO PORCHES. 1ST PORCH ... (7842-44) ... 3 STORY WOOD, OPEN FRAME PORCH ... THE 6"X6" STRUCTURAL COLUMN SECTIONS (SUPPORTING THE PORCH DECKS) ARE IMPROPERLY FASTENED TO ONE ANOTHER. THEY HAVE BEEN STACKED ATOP ONE ANOTHER WITH NO FASTENERS WHAT SO EVER. ALSO, THESE 6"X6" COLUMNS ARE SEVERELY OVER NOTCHED (DOUBLE RIM JOIST CONECTIONS); THIS HAS REDUCED THE COLUMNS' ORIGINAL DIMENSION FROM 6"X6" TO 6"X2". THESE COLUMN SECTIONS HAVE REDUCED STRUCTURAL INTEGRITY DUE TO THIS IMPROPER OVER NOTCHING. ALSO, THE COLUMNS SUPPORTING THE STAIR FLIGHTS AND STAIR LANDINGS ARE UNDERSIZED 4"X4" BOARDS. ALL STRUCTURAL CONECTIONS ASSOCIATED WITH THESE COLUMNS ARE NAIL JOINTED ... THERE ARE NO BOLTED CONECTIONS OR STRUCTURAL SUPPORT BRACKETS. THE STAIR AND PORCH BANISTERS ARE TOO LOW (38"). THERE ARE NO METEAL TIE BACK CLIPS TO FASTEN THE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POSTS FOR THESE BANISTERS ARE NAILED, NOT BOLTED. THE SATIR FLIGHTS ARE 14 STEP SECTIONS FROM TOP TO BOTTOM WITHOUT AN IMTERMEDIATE LANDING. THERE ARE ALSO SUBSTAINDARD (UNDERSIZED) BEAMS SUPPOORTING THE PORCH DECKS (SINGLE 2"X8" BOARDS).THIS PORCH IS BEYOND UPGRADE STATUS ... INCORRECTLY BUILT AND IN VERY POOR CONDITION ... RECOMMEND TEASR DOWN AND REPLAC E WITH NEW. PLANS AND PERMIT ARE REQUIRED.2CD PORCH ... (2218-2226). 3 STORY OPEN WOOD FRAME PORCH. ALL FOOTINGS FOR THE STRUCTURAL COLUMNS ARE OF AN UNDERMINED DEPTH. THE 6"X6" COLUMN / BEAM JOINTS ARE (OVER) NOTCH JOINTED. THESE JOINTS ARE PULLING APART. THERE ARE NO STRUCTURAL BRACKETS AT THESE VITAL JOINTS FOR SUPPORT AND CONECTION. THERE ARE ALSO 2 TYPES OF UNDERSIZED COLUMNS BEING USED FOR STRUCTURAL SUPPORT (4"X6" AND 4"X4"). THE BANISTER SECTIONS ARE TOO LOW (38"). THERE ARE NO METAL TIE BACK CLIPS TO CONECT THESE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POST ARE NAIL, NOT BOLT FASTENED. THE STAIR FLIGHTS ARE 14 STEP RUNS WITHOUT ANY INTERMEDIATE LANDINGS. THIS PORCH IS NOT UP TO MINIMUM CODE ... TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT ARE REQUIRED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT COMPLETE. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION CORNICE OPEN MORTAR JOINT. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION 1ST FLOOR SPRAWING BRICK AND WASHED OUT MORTAR | 2218 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. COMMERCIAL SPACES ARE EITHER CLOSED OR VACANT AT TIME OF INSPECTION. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / 3RD FLOOR EXTERIOR WALL - MASONRY FRACTURES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | 2226 / FRONT WINDOW - BOARDED WITH PLYWOOD. . | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | TWO PORCHES. 1ST PORCH ... (7842-44) ... 3 STORY WOOD, OPEN FRAME PORCH ... THE 6"X6" STRUCTURAL COLUMN SECTIONS (SUPPORTING THE PORCH DECKS) ARE IMPROPERLY FASTENED TO ONE ANOTHER. THEY HAVE BEEN STACKED ATOP ONE ANOTHER WITH NO FASTENERS WHAT SO EVER. ALSO, THESE 6"X6" COLUMNS ARE SEVERELY OVER NOTCHED (DOUBLE RIM JOIST CONECTIONS); THIS HAS REDUCED THE COLUMNS' ORIGINAL DIMENSION FROM 6"X6" TO 6"X2". THESE COLUMN SECTIONS HAVE REDUCED STRUCTURAL INTEGRITY DUE TO THIS IMPROPER OVER NOTCHING. ALSO, THE COLUMNS SUPPORTING THE STAIR FLIGHTS AND STAIR LANDINGS ARE UNDERSIZED 4"X4" BOARDS. ALL STRUCTURAL CONECTIONS ASSOCIATED WITH THESE COLUMNS ARE NAIL JOINTED ... THERE ARE NO BOLTED CONECTIONS OR STRUCTURAL SUPPORT BRACKETS. THE STAIR AND PORCH BANISTERS ARE TOO LOW (38"). THERE ARE NO METEAL TIE BACK CLIPS TO FASTEN THE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POSTS FOR THESE BANISTERS ARE NAILED, NOT BOLTED. THE SATIR FLIGHTS ARE 14 STEP SECTIONS FROM TOP TO BOTTOM WITHOUT AN IMTERMEDIATE LANDING. THERE ARE ALSO SUBSTAINDARD (UNDERSIZED) BEAMS SUPPOORTING THE PORCH DECKS (SINGLE 2"X8" BOARDS).THIS PORCH IS BEYOND UPGRADE STATUS ... INCORRECTLY BUILT AND IN VERY POOR CONDITION ... RECOMMEND TEASR DOWN AND REPLAC E WITH NEW. PLANS AND PERMIT ARE REQUIRED.2CD PORCH ... (2218-2226). 3 STORY OPEN WOOD FRAME PORCH. ALL FOOTINGS FOR THE STRUCTURAL COLUMNS ARE OF AN UNDERMINED DEPTH. THE 6"X6" COLUMN / BEAM JOINTS ARE (OVER) NOTCH JOINTED. THESE JOINTS ARE PULLING APART. THERE ARE NO STRUCTURAL BRACKETS AT THESE VITAL JOINTS FOR SUPPORT AND CONECTION. THERE ARE ALSO 2 TYPES OF UNDERSIZED COLUMNS BEING USED FOR STRUCTURAL SUPPORT (4"X6" AND 4"X4"). THE BANISTER SECTIONS ARE TOO LOW (38"). THERE ARE NO METAL TIE BACK CLIPS TO CONECT THESE BANISTER SECTIONS TO THEIR SUPPORT POSTS. THE SUPPORT POST ARE NAIL, NOT BOLT FASTENED. THE STAIR FLIGHTS ARE 14 STEP RUNS WITHOUT ANY INTERMEDIATE LANDINGS. THIS PORCH IS NOT UP TO MINIMUM CODE ... TEAR DOWN AND REPLACE WITH NEW ... PLANS AND PERMIT ARE REQUIRED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | REAR ELEVATION: WEST GATE CHAINED; NORTH GATE DOUBLE KEYED | 2218 E 79TH ST | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | INTERIOR DOORS -MISSING PEEP HOLES. | 2218 E 79TH ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | INTERIOR STAIRS &APTS WORN OUT LOOSE RAILS | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR STAIRS CRACKED PLASTER. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR STAIRS &APTS MISSING & DEFECTIVE DETECTORS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REAR EXIST PORCH JUNK &DEBRIS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED -2005-2006. | 2218 E 79TH ST | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | FRONT STORES - VACANT & SECURED. | 2218 E 79TH ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR AND PORCH AREA TO VIEW OLD VIOLATIONS. | 2218 E 79TH ST | PERIODIC | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | 2226 STORE FRONT; VACANT. | 2218 E 79TH ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | 2226 STORE FRONT, WINDOW FRAME; BROKEN. | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | 2226 STORE FRONT, FOUNDATION WALL AT GRADE; BROKEN STONE AND PUSH IN.[SUBMIT PERMITS FOR REPAIRS] | 2218 E 79TH ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION, EXTERIOR WALL; MORTAR MISSING. | 2218 E 79TH ST | PERIODIC | FAILED | View |
LOOSE PLATE GLASS | 2226 STORE FRONT, PLATE GLASS; BROKEN. | 2218 E 79TH ST | PERIODIC | FAILED | View |