Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | THREE STORY REAR PORCH FROM GRADE TO THE ROOF. THE STRUCTURAL COLUMN SECTIONS ARE STACKED ON TOP OF ONE ANOTHER WITH NO MECHANICAL FASTENERS AND NO JOINTED CONECTIONS. THERE ARE NUMEROUS LOOSE / DETACHED STAIR TREADS.THE STAIR STRINGERS ARE OVER NOTCH CUT.THE STAIR FLIGHT BETWEEN THE 2CD FLOOR AND THE ROOF (NOTE: THIS ROOF HAS A SECTION AT THE FRONT OF THE BUILDING THAT IS ACTUALLY A 3RD FLOOR DWELLING UNIT) IS ONLY 24" WIDE.THIS PORCH IS IN DANGEROUS AND HAZARDOUS CONDITION. PLANS AND PERMIT REQUIRED TO REPAIR OR REPLACE. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | THE 3RD FLOOR UNIT HAS A REAR EXIT THAT CROSSES 35 FEET OF OPEN, FLAT ROOF BEFORE THE REAR PORCH IS REACHED. THERE IS NO EXIT WALKWAY WITH GAURDRAILS TO FUNNEL EGRESS TO THE REAR PORCH. DANGEROUS AND HAZARDOUS EGRESS. PLANS AND PERMIT REQUIRED TO CONSTRUCT THIS EXIT PATHWAY. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
WORKING ON STOP WORK ORDER | A FULL REHAB IS BEING PERFORMED TO THE 3RD FLOOR FRONT UNIT WITHOUT PLANS OR PERMIT. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THIS 501(C)(3) ROOMING HOUSE IS UNLICENCED AND DOES NOT CONFORM TO MINIMUM BUILDING CODE REQUIREMENTS. PLANS AND PERMIT ARE REQUIRED BASED ON THIS ORRIGINAL 3 UNIT BUILDING BEING ALTERED INTO A NOW EXISTING ROOMING HOUSE. BASEMENT (5 MATRESSES). 1ST FLOOR (OFFICE AND 4 ROOMING UNITS). 2CD FLOOR (4 ROOMING UNITS). 3RD FLOOR (WIP REHAB ... UNABLE TO DETERMINE TYPE OF DWELLING UNIT). | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL EXIT SIGN | FROM THE BASEMENT TO THE 3RD FLOOR THERE IS MISSING DIRECTIONAL SIGNAGE. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | THE STAIRWELL ENCLOSURE FROM THE 1ST TO THE 3RD FLOOR IS WOOD LATH AND PLASTER. THE STAIRWELL FROM THE BASEMENT TO THE 1ST FLOOR HAS NO ENCLOSURE. A 1 HOUR FIRE RESISTIVE ENLOSURE IS REQUIRED. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
STAIR: SELF-CLOSE 1-3/4" DOOR | THERE ARE NO CLASS B FIRE DOORS WITH SELF CLOSING DEVICES. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | THE BASEMENT CEILING IS OPEN WITHOUT A MINIMUM 1 HOUR FIRE RATED COVERING. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | THERE ARE NO FIRE EXTINGUISHERS IN THIS ROOMING HOUSE. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | THE STAIRWELL (FRONT) FROM THE BASEMENT TO THE 3RD FLOOR HAS NO ILLUMINATION. | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROVIDE | THERE ARE NO CLASS B FIRE RATED DOORS AT ANY OF THE STAIRWELL OPENINGS. SECTION 4(13-206-50). | 3525 W JACKSON BLVD | COMPLAINT | FAILED | View |